12
I
NSTALLATION
EAS Deactivation
SW1 and SW2 are the switch banks inside the Checkpoint Device that set the
deactivation range. The following is a list of Checkpoint recommended switch
bank settings.
Checkpoint Recommended Switch Bank Settings
SW1
SW2
RS232, Keyboard Wedge, & RS485
Switch 5
ON
Switch 5
ON
Switch 1, 2, 3, 4 & 6
OFF
Switch 1, 2, 3, 4 & 6
OFF
USB
Switch 2 & 3
ON
Switch 2 & 3
ON
Switch 1, 4, 5 & 6
OFF
Switch 1, 4, 5 & 6
OFF
All Orbit
CG
models are equipped with EAS capabilities. Orbit
CG
’s
optional
EAS
cable is equipped with additional wires for connection to a Checkpoint Device.
Figure 14. EAS Cable
Figure 15 shows the location of the EAS
deactivation area for Orbit
CG
.
It is important to pass the entire tag through
this area to deactivate the security tag.
Figure 15. EAS Deactivation Area