Honeywell
THE R841 ELECTRIC HEATING RELAY IS
USED WITH A 2-WIRE, 24V THERMOSTAT
TO PROVIDE CONTROL OF ELECTRIC
HEATING EQUIPMENT. IT IS A DIRECT-
FOLLOWING RELAY WHICH OPERATES
WITH EACH CYCLE OF THE THERMO-
STAT (4 TO 6 CYCLES PER HOUR).
❑
models are used to control one
load.
❑
is used either with one thermostat
to control two loads simultaneously, or with
two thermostats to control two independent
loads.
❑
and E models include an integral
transformer; R841 D model must be powered
from a remote 24V transformer.
❑
and D models have a 1/2 inch male
conduit bushing.
❑
The
and E models are for instal-
lation on a wireway or J-box.
❑
R841 E has a 1/2 inch male conduit bushing
and includes an enclosure with a low voltage
wiring compartment.
❑
Special
with 10 second minimum
timing between stages is available.
❑
Each relay switches up to a 5,000 watt load.
❑
Spst MICRO SWITCH snap switches are
actuated by ambient-compensated
strips.
❑
Leadwires are provided for both line voltage
and low voltage connections.
❑
Small size and silent operation allow instal-
lation in living area, utility room, or basement,
❑
May be mounted in any convenient position.
REV. 10-79 (.11)