Site Hardware
Eleven-Minute Delay
If the DVR fails to function, report alarms or record video due to hardware failure, for more
than 11 minutes, the FAULT RELAY is triggered.
Immediate Trigger
A power outage triggers the relay immediately.
Alarm When Disabling Video Recording
A Rapid Eye LT DVR can be monitored for operator tampering with recording. Refer to the
Rapid Eye™ Multi-Media Digital Video Recorder System Administrator Guide
, in the tracing
section.
Temperature
A Rapid Eye LT DVR can be operated in a non-condensing environment, in temperatures
ranging from 40°F to 104°F (or 5°C to 40°C).
Caution
Excessive heat (above 104°F) will shut down the DVR.
Response Schedule
Vandalism
One can add rules to trigger an output if video recording fails due to a cut cable, dead
camera or other failure that is not related to DVR performance. Consult the
Multi-Media Digital Video Recorder System Administrator Guide
, in the Response Schedule
section.
Point-of-Sale Hardware
Connect a point-of-sale (POS) device or other data communication equipment to any of:
SERIAL PORTs 1 to 2
Use RS232 connectors (see
).
SERIAL PORTs 3 to 4
Use RS485 connectors (see
).
Summary of Contents for Rapid Eye LT