INSTALLATION INSTRUCTIONS
69-1792-09
S9360B, S9361B, S9370B, S9371B,
S9380B, S9381B
Integrated Water Heater Controllers
APPLICATION
These integrated water heater control modules
provide ignition sequence, flame monitoring and
safety shutoff for either intermittent pilot spark
ignition or direct hot surface ignition heating
systems. They also provide limit rated water
temperature control and display interface capability
for either “on-board” or remote user interface
applications. Cover shown is optional.
• S9360B—Spark Ignition, Intermittent Pilot, Remote
Display, Water Heater Applications.
• S9361B—Spark Ignition, Intermittent Pilot, “On
board” Display, Water Heater Applications.
• S9370B—Hot Surface Ignition, Remote Display,
Water Heater Applications.
• S9371B—Hot Surface Ignition, “On board” Display,
Water Heater Applications.
• S9380B—Direct Spark Ignition, Remote Display,
Water Heater Applications
• S9381B—Direct Spark Ignition, “On board” Display,
Water Heater Applications
• All models are enabled with EnviraCOM™
communication capability to support remote
monitoring and diagnostics.
• Limit-rated Temperature Sensing Probe.
• One or Two Sensor Models.
SPECIFICATIONS
IMPORTANT:
The specifications given in this publication do
not include normal manufacturing
tolerances. Therefore, an individual unit may
not match the listed specifications exactly.
Also, this product is tested and calibrated
under closely controlled conditions, and some
minor differences in performance can be
expected if those conditions are changed.
Model Numbers
Dimensions:
See Fig. 1.
S—Switching Control
9
3—Integrated Hydronic Control Platform
6—Spark Ignition
7—Hot Surface Ignition
8—Direct Spark Ignition
0—Remote Display Required
1—Integrated On-Board Display
A—Boiler Control
B—Water Heater Control
C—Pool Heater Control
1—No Circulator
2—On/Off Circulator
3—Variable Speed Circulator
S
9
3
6
0
A
1
000