High-Level Input Channel
12.1 Features
The High-Level Input channel provides a DC supply voltage to and accepts volt-
age or current signals from amplified transducers such as pressure transducers,
load cells and DC-DC LVDTs. These signals are digitized, converted into engi-
neering units, and placed into the track, peak and valley data values of the chan-
nel. Setup and calibration of the channel is made manually through the SETUP
menu mode.
Signature Calibration
is not available with amplified transducers.
The analog-to-digital converter input circuit features adjustable digital, low-pass
filtering, 12- to 18-bit resolution (depending on the filter setting) and has several
different input ranges. These many ranges allow ±50,000 count resolution (at the
slowest filter setting) across a wide variety of input ranges.
A combination of SETUP menu items and hardware jumpers are used to config-
ure the excitation supply output voltage (+28 VDC, ±15 VDC, +15 VDC or +12
VDC), the input type (voltage or current) and input reference (differential or single
ended).
Two methods of calibrating the High-Level Input channel to the transducer are
available: known-load calibration and shunt calibration. The benefits of each are
discussed in “
Two rear panel control inputs can be field-configured for such functions as remote
tare, disabling peak/valley detection and clearing the peak/valley values. A volt-
age or current digital-to-analog output is also provided.
Summary of Contents for SC500
Page 8: ...page 8 008 0671 00 ...
Page 14: ...page 14 008 0671 00 ...
Page 18: ...page 18 008 0671 00 ...
Page 24: ...page 24 008 0671 00 ...
Page 38: ...page 38 008 0671 00 ...
Page 42: ...page 42 008 0671 00 ...
Page 50: ...page 50 008 0671 00 ...
Page 72: ...page 72 008 0671 00 ...
Page 82: ...page 82 008 0671 00 ...
Page 90: ...page 90 008 0671 00 ...
Page 116: ...page 116 008 0671 00 ...
Page 126: ...page 126 008 0671 00 ...