Introduction
Digital Output Version
In normal state
During an alarm
Electrochemical-cell-type sensors
0.5 W
1.0 W
Catalytic-type sensors
1.6 W
2.0 W
Infrared-type sensors
1.0 W
1.5 W
Operating Environment
Operating temperature
−40 to 65 °C (−40 to 140 °F)
Storage temperature
0 to 30 °C (32 to 86 °F)
Humidity
0 to 99% (non-condensing)
†
Atmospheric pressure
90 to 110 kPa
Installation category
II (UL/CSA/IEC/EN 61010-1)
Pollution degree
2 (UL/CSA/IEC/EN 61010-1)
†
Flammable catalytic versions: 10 to 90% RH. Operating the detector outside of this
range may result in increased drift and a reduction in detector accuracy.
Recommended Wall-Mounting Screws
Type
Countersunk, pan head
Size
6 mm (No. 14) diameter × 38 mm (1.5 in) min.
Cable Entry
ATEX/IECEx
2 × M20
cULus
2 × ¾ NPT
Gas
See
Detector Parameters
on page 40 for a full list of detectable gases,
ranges and other information.
11