Installation and Commissioning

Instructions

Silver Series LightSpot with photocell

MS1201PF / MS1201PSM
MS1221PF / MS1221PSM

MS1201PSM
MS1221PSM

MS1201PF 
MS1221PF

W4231G

Ex-Or 

Novar ED&S Limited
Haydock Lane, Haydock, Merseyside WA11 9UJ

Tel: +44 (0)1942 719229 
Fax: +44 (0)1942 508753  
Email: technicalsales.ex-or@honeywell.com
www.ex-or.com

At the end of their useful life 
the packaging and product 
should be disposed of via a 
suitable recycling centre.
Do not dispose of with normal 
household waste.
Do not burn.

by Honeywell

Note: Infrared Programmer required for commissioning 

HP2000, HP10 or HP18 for MS1201PF/SM
HP2000 or HP10 for MS1221PF/SM 

Please note that only the HP2000 offers the full range of programming options

User override available via HC5 or HC6 Hand-held Controllers

Summary of Contents for Silver Series

Page 1: ...nicalsales ex or honeywell com www ex or com At the end of their useful life the packaging and product should be disposed of via a suitable recycling centre Do not dispose of with normal household waste Do not burn by Honeywell Note Infrared Programmer required for commissioning HP2000 HP10 or HP18 for MS1201PF SM HP2000 or HP10 for MS1221PF SM Please note that only the HP2000 offers the full rang...

Page 2: ... 3 Ameans for disconnection must be incorporated in the fixed wiring in accordance with the current wiring regulations 4 This equipment switches lights no more frequently than would a responsible human occupant However manufacturers of some lighting types e g 2D luminaires may specify a maximum number of switching cycles and or a minimum on time in order to achieve a predicted lamp life Please che...

Page 3: ...ed load on and off as required whilst natural light levels fluctuate during a period of occupancy This mode of operation operates in conjunction with a passing cloud timer PCT The PCT is asymmetrical in operation the load will be switched on immediately that the light level falls below the lower set point however the load switches off only if the light level exceeds the upper threshold continuousl...

Page 4: ...own momentarily on the HP2000 screen following the Download this is a useful mechanism for troubleshooting Washroom Mode The unit may be used in conjunction with a 230V solenoid valve and a trickle valve or petcock to effect a urinal flush system Set the water flow rate by adjusting the petcock so that the cistern just fills within the chosen Off Delay period of the detector Note that in this mode...

Reviews: