background image

 

 

SiX

TM

 

Series

 

SiXSMOKE / SiXSMOKE-CN

 

Installation Instructions

 

 

 

 

This wireless smoke/heat detector 
is intended for use with Honeywell 
controls that support SiX™ series 
devices. 

 

To remove the mounting bracket, 

turn the top of the detector 15 
degrees counterclockwise and 
separate the mounting bracket and 
top cover.

 

 

SiXSMOKE / 

SiXSMOKE-CN 

PULL 

TO

CONNECT

PULL 

TO

CONNECT

 

Open 

Enroll 

 

This device can be enrolled and programmed either 
before or after installation.

 

1.  Set the 

Lyric Controller

 in Programming Mode and go 

to Zone Programming.  Select Add New and then 
Serial Number.  

2.  Remove the battery tabs to activate the device and 

begin the enrollment process. 

3.  The Green LED flashes rapidly during enrollment (up 

to about 20 seconds*). 

*NOTE

: Enrollment time varies depending on the signal 

strength between the device and the controller. 

  The detector sends its unique MAC ID (Serial 

Number) and Services information to the controller.   

  The controller registers the device and displays the 

transmitter data on screen. 

4.  Enrollment is confirmed when the Green LED is ON 

for 3 seconds and the device chirps. 

5.  Repeat the process, pressing the Test Switch to start 

enrollment, and select Heat Sensor Device type to 
enroll the heat sensor.  The device will enroll the 
same MAC ID in another Zone. 

6.  Press SAVE. 

If the detector is not successfully enrolled during the 
enrollment period, the LED turns off and the device 
powers down.  Activate the tamper or press the Test 
switch to restart the enrollment process.  

The device can also be manually enrolled.  See the 
Controller’s Programming Guide for details.

 

Serial Number

Loop Number

Zone Description 1

Zone Description 2

Device Type

Response Type

Alarm Report

Chime

Supervision

Panic

Home

1

3

4

The Green LED is
ON for 3 seconds

Programming Mode > Zones > 
     Add New > Serial Number

The LED 

Flashes for 

up to about 

20 seconds

30

0

45

20

10

2

Trigger the device 
again to complete 
enrollment

PULL 

TO

CONNECT

PULL 

TO

CONNECT

PULL 

TO

CONNECT

PULL 

TO

CONNECT

5

Press SAVE

6

 

Enroll

 

After enrolling, update the detector firmware

 (via the 

Controller) to ensure the latest version is used.  See the 
Controller’s instructions. 

NOTE

: Once enrolled in a system, the detector cannot be used 

with another controller until it is removed from the current 
controller. See the Controller’s instructions for details. 

Program  

Consult the Controller’s instructions to program the device in the system. 

Fault device features to learn the device Services in the controller:  

-

 

Smoke and Heat detector  - Reports to panel: 

  Smoke Alarm when smoke is detected 

  Temperature Alarm when temperature of 135° F (57° C) or greater OR when there is a 

temperature increase of 15° F (8.33° C) or greater within one minute 

-

 

Percentage of obscuration (smoke or dirt in the detector)   

-

 

Cover tamper: The 10 minute tamper timer is reset every time the tamper switch is closed and 
opened or the detector cover is opened. 

-

 

Supervision –  200 second check-in compatible

 

NOTE

: If programmed in 

the panel to operate in 
one-go-all-go mode, all 
smoke detectors 
programmed as one-go-
all-go in the system will 
sound on alarm. 

Summary of Contents for SiXSMOKE

Page 1: ...press the Test switch to restart the enrollment process The device can also be manually enrolled See the Controller s Programming Guide for details Serial Number Loop Number Zone Description 1 Zone Description 2 Device Type Response Type Alarm Report Chime Supervision Panic Home 1 3 4The Green LED is ON for 3 seconds Programming Mode Zones Add New Serial Number The LED Flashes for up to about 20 s...

Page 2: ...e Mount Test The detector should be tested immediately after installation and at least once a year Recommended To prevent unwanted alarms notify the Central Station that the smoke detector system is undergoing maintenance before testing begins Test Mode can be activated remotely from the Controller see the Controller s manual or on site by pressing the test switch Tests and testing methods Test Sw...

Page 3: ...rts chirping after 7 days and continues until the batteries are replaced or die To quiet the sounder for 5 minutes press the Test Switch does not work when set in one go all go mode See Battery Replacement section To silence the detector Press the test switch or disarm the system at the controller The detector sounds again after 5 minutes if the alarm condition continues When programmed in one go ...

Page 4: ...LIMITATIONS OF THE ENTIRE ALARM SYSTEM 2014 Honeywell International Inc Honeywell and is a registered trademark of Honeywell International Inc All other trademarks are the properties of their respective owners All rights reserved 6 Reinsert the screen sensing chamber and press firmly to set it in place 7 Reinsert the detector cover back over the screen sensing chamber and turn it clockwise until i...

Reviews: