Operating
Modes
and
Quick
Actions
EN2H-0402GE51 R0316
20
Normally after 10:00 p.m., no hot water production is executed. But at 2:00 a.m., hot
water is needed for a shower (e.g., in order to catch an early flight).
When setting of the start time of this action, the (additional) time for heating up the hot
water reservoir of the heating system must be considered.
thus, the start time of the action is set to 1:30 a.m. and the action is activated.
Hot water production then starts at 1:30 a.m. and the dedicated rooms will heat-up to
comfort temperature.
Note
• The time needed for heating up the hot water storage tank depends on the
corresponding heating system and has to be determined anew for each
installation.
• The "Shower" action is available only if the heat generator is connected via the
Smile Bus.
Warm-Up Boost Action
The "Warm-up boost" action provides a fast achievement of the comfort temperature in
the dedicated rooms. When activated, the comfort temperature plus a fixed temporary
temperature increase will heat up the rooms as quick as possible.
The duration of the function is defined, or can be made visible by tapping again on the
icon.
The run time of the action can be adjusted in 30-minute steps until a max. of 120 minutes.
Standby Action
The "Standby" action switches off the heating. The antifreeze protection is activated and
hot water production is disabled.
9.2.1 Applying
an
Action
To apply an action to a dedicated number of rooms, proceed as follows:
• select
the
action;
• select
the
rooms;
• adjust the length of time (depending on the action: days, hours, minutes, start time
and switch off of the "Standby” action);
• start
the
action.
Note
Multiple actions per room can be executed simultaneously. Activated actions are
displayed in red color.
The heating circuit demand is always carried out according to the principle of
"comfort before efficiency," i.e., the action with the higher set point is executed
first.