day from the program, use the Day key to advance to that day
and press the Sel. (select) key. The chosen day flashes.
Continue pressing the Day and Sel. keys to delete additional
days until only the desired days remain and the remaining
days are not flashing on the display.

G

Press the Prog. key and repeat steps 

B

 through 

F

 to enter

additional programs for on and off times.

NOTE:

More than one off time program can be entered to
gain automatic control of manual overrides.

H

Press the         key to enter the Run Mode.

Set Eighth Day Holiday/Vacation Program

Multiple programs (more than one on and off time) can be entered for
holidays or vacation periods. Example: Enter off, and 12:01 AM to
shut off the load(s) on vacations and holidays.

A

Press the Prog. key, select on or off, and use h and m to enter
the hour and minutes, but do not select or delete any days.

B

Press the         key.         is displayed indicating the Eighth Day
Holiday/Vacation Program.

C

Press the         key to enter the Run mode. The time switch is
now permanently preset with the on/off schedule to be
implemented for holidays and extended vacation periods. See
Set Holiday Program section.

Set Holiday Program

The Holiday Program can be implemented at any time up to six days
in advance of the holiday(s) or vacation period. It can also be
activated on the holiday or first day of the vacation period.

A

When in the Run Mode, press the         key. -:-HO is displayed.

B

Press the Day key to select the day of the week that the
Holiday Program should begin.

C

Press the Sel. key to select the number of days that the
Holiday Program should run. (Enter up to 99 days. If the Sel.
key is held down, the numbers scroll up rapidly to 99 and then
start over with 01).

D

Press the         key to store the program. The holiday symbol
is displayed.

E

To review or change the Holiday Program, press the         key.
To cancel the Holiday Program, press the       key a second time.

On the day the Holiday Program begins, the Eighth Day Program is
implemented at 12:00 AM Midnight taking priority over the regular
daily programs. The holiday symbol and the number of days of the
program run are displayed. Each day is counted down until all days of
the holiday/vacation period are shown. When complete, the display
reverts to normal. To cancel the Holiday Program, press the       key.

IMPORTANT

The output relays switch on or off only at the programmed
times. After programming is complete, if the switch is
desired in the on position, it must be turned on manually

with the         key. Example: Programming was completed at
2:00 PM and CH1 was programmed to be on at 8:00 AM
and off at 5:00 PM. After pressing the         key, CH1 turns
off. Press         to turn it on. Automatic operation begins at
the 5:00 PM off time.

Review and Change of Programs

A

To review a program at any time, press the Prog. key. Each
press of the Prog. key displays a program in the sequence it
was entered.

B

To change a program, select the program to be changed with
the Prog. key, and enter the new time of day and/or days of
the week as done in the Set Holiday Program section. The old
program is overwritten with the new selections. Press the
Prog. key to store the new program.

C

To delete an individual program, select the program as
explained in step 

and press the m key and then the key

until -:- is displayed. Press either the Prog. or the         key
until -:- flashes. The program is deleted after a few seconds.

Manual Override

When in the Run Mode, (         symbol is displayed), press the
key to reverse the load status (switch the load off if on, or on if off).
The hand symbol is displayed to indicate that the override is active.
At the next scheduled switching time, the automatic time control
resumes, eliminating the override.

Press the         key a second time. [       ] is displayed indicating

the load is switched permanently on.

Press the         key a third time. [       ] is displayed indicating the

load is switched permanently off.

Press the         key a fourth time to return to automatic

programming.         is displayed.

TERMINAL DESIGNATIONS

M

1

2

3

4

5

INPUT

M11346

6

7

8

NO

NC

NO

NC

ISOLATED CONTACTS

CIRCUIT 1

CIRCUIT 2

ST7009B,D

M

1

2

3

4

5

INPUT

NO

NC

ISOLATED CONTACTS

ST7009A,C

Summary of Contents for ST7009A

Page 1: ...Universal 24 hour or 7 day programming accurate to the second UL and CUL recognized components Multiple on off daily programs with unlimited flexibility Program simplicity with a minimal number of keys and program steps Holiday programming Built in program backup Daylight Savings Time changeover in the spring and fall Screw wiring terminals All models feature large keys and a large LCD display for...

Page 2: ...ST7009A C Surface or DIN Rail ST7009B D Panel or Surface Switching Capacity 16A resistive at 277 Vac 1000W tungsten at 240 Vac 1 2 hp at 120 Vac 1 hp at 240 Vac Shortest Switching Time 1 minute Accuracy 4 minutes per yr Ambient Temperature 20 F 28 C to 140 F 60 C Ambient Humidity 0 to 95 RH non condensing LCD Time Display Selectable AM PM or 24 hour Manual 3 way Override Temporary or permanent on ...

Page 3: ...y once A 4 is displayed under Th Enter the date for Summer Daylight Savings Time changeover for the current year by entering the date with the m key and the month with the h key If in military time set the date with the h key and the month with the m key Example April 7 is displayed as 04 07 if in AM PM time or 07 04 in military time G Press the 1h key once A 5 is displayed under Fr Enter the date...

Page 4: ... the Sel key is held down the numbers scroll up rapidly to 99 and then start over with 01 D Press the key to store the program The holiday symbol is displayed E To review or change the Holiday Program press the key To cancel the Holiday Program press the key a second time On the day the Holiday Program begins the Eighth Day Program is implemented at 12 00 AM Midnight taking priority over the regul...

Reviews: