9 - 34
Addenda Timeout
You can set a time during which the scanner looks for an addenda. If an addenda is not found within this time period, the
data can be either transmitted or discarded, based on the setting you are using for
UPC-A Number System 4 Addenda
Required
or
UPC-A Number System 5 Addenda Required
. Set the length (in milliseconds) for this timeout by scanning the
bar code below, then setting the timeout (from 0-65535 milliseconds) by scanning digits from the
Programming Chart
, then
scanning
Save
.
Default = 100.
Note: The Addenda Timeout setting is applied to all addenda and coupon code searches.
Coupon GS1 DataBar Output
If you scan coupons that have both UPC and GS1 DataBar codes, you may wish to scan and output only the data from the GS1
DataBar code. Scan the
GS1 Output On
code below to scan and output only the GS1 DataBar code data.
Default = GS1 Out-
put Off.
Require Coupon Code
Require Coupon Code or 2 Digit
Addenda
Require Coupon Code or 5 Digit
Addenda
Require Coupon Code, 2 Digit
Addenda, or 5 Digit Addenda
Addenda Timeout
* GS1 Output Off
Summary of Contents for Stratos 2700
Page 1: ...Stratos 2700 Bioptic Scanner Scale User s Guide ...
Page 6: ......
Page 20: ...1 6 ...
Page 36: ...2 16 ...
Page 96: ...5 4 ...
Page 110: ...6 14 ...
Page 130: ...8 14 ...
Page 203: ...9 73 Maximum Message Length ...
Page 204: ...9 74 ...
Page 212: ...11 2 Denmark 8 9 6 Norway 8 9 6 Spain 6 Country Codes ...
Page 214: ...11 4 ...
Page 218: ...12 4 ...
Page 244: ...13 26 ...
Page 250: ...14 6 ...
Page 256: ...15 6 ...
Page 270: ...B 2 ...
Page 273: ...Programming Chart 0 1 2 3 4 5 6 7 8 ...
Page 274: ...9 A B C D E F Save Discard ...
Page 276: ......
Page 277: ......