GK Solenoid Safety Interlock Switch
ISSUE 2
PK 81591
For application help: call 1-800-537-6945
Honeywell
•
MICRO SWITCH Sensing and Control 2
SAFETY ANALYSIS TECHNIQUES
1. Conduct Hazard Analysis and Risk
Assessment
Refer to:
•
OSHA Title 29, ANSI Standards.
•
European Norm EN 1050, Safety of Machines
Risk Assessment.
2. Review Requirements and Safety Related
Parts of the Control System
•
ANSI B11.19-1990 -- Safeguarding When
Referenced by the Other B11 Machine Tool
Safety Standards.
•
ANSI B11.20 -- System Energy Stopping.
•
European Norms:
−
EN954-1: Safety Related Parts of the Control
Systems.
−
EN60204-1: Electrical Equipment of Machines.
−
prEN1088: Interlocking Devices With and
Without Guard Locking.
•
Any other appropriate industry safety standards.
PERFORM INSTALLATION AS FOLLOWS:
1. Assemble Switch Head (applies to Head
Option “E” and “K” only)
The one-way screws must be used on this head
option to prevent voiding the warranty.
Head options “E” and “K” are shipped unattached
and may be indexed in 90
°
increments (Figure 2).
•
Rotate auxiliary release (1) to unlock position.
•
Properly seat:
−
Factory-installed “O” ring (2) in its seal groove.
−
Plunger (3).
•
Determine required key entry location.
•
Securely fasten operating head to switch housing
with the four one-way screws provided. Torque
screws to 1,36-1,80 N-m (12-16 in-lb).
•
Rotate auxiliary release back to lock position.
Figure 2: Head Options “E” and “K”
1
2
3
UNLOCK
LOCK
2. Mount, Wire and Seal Switch
Step 1 - Ensure you have the following:
•
Switch and key.
•
Wire (use 90
°
C wire when ambient temperature is
over 75
°
C):
−
Stranded: 0.75 mm
2
2.5 mm
2
, 18-14 AWG, or
−
Solid: 0.75 mm
2
to 1.5 mm
2
, 18-16 AWG.
•
M5 or #10 screws.
Step 2 - Mount switch and key:
IMPROPER INSTALLATION
•
Ensure key travels to the minimum insertion
dimension to ensure switch contact transfer
(Figure 4).
•
Ensure key travels to maximum extraction
distance to ensure correct operation of the
positive break mechanism.
•
Do not exceed 100 N (22.4 lb) actuation force to
key to prevent switch failure (Table 1).
•
Do not use the key as a stop for the door.
Failure to comply with these instructions
could result in death or serious injury.
Table 1: Force Characteristics*
Key actuation force for
head with detent
51 N (11.5 lb) minimum
Key extraction force for
head with detent
31 N (7 lb) minimum
Key actuation force for
head without detent
22 N (5 lb) minimum
Key extraction force for
head without detent
2 N (0.5 lb) minimum
*Device is in unlocked state.
•
Ensure proper clearance for switch and key at
mounting location so that operation of the auxiliary
release, as well as inspection and replacement,
are possible.
•
Properly align switch and key together before
mounting to equipment.
•
Mount switch and key (Figures 3 and 4).
−
Torque switch to mounting surface: 4,9-5,9 N-m
(43-52 in-lb) M5 or #10.
−
Torque key to mounting surface: 2,4-2,8 N-m
(21-25 in-lb) M5 or #10.
Summary of Contents for SYA14 Series
Page 2: ...2 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 6: ...6 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 26: ...26 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 62: ...62 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 70: ...70 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 76: ...76 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 78: ...78 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 79: ...107031 23 EN FR26 GLO 1199 Printed in France 79 8 CE Declaration of Conformity ...
Page 80: ...80 107031 23 EN FR26 GLO 1199 Printed in France This page has been left intentionally blank ...
Page 84: ......
Page 158: ......
Page 160: ......
Page 161: ...For application help call 1 800 537 6945 Honeywell MICRO SWITCH Sensing and Control 80 ...
Page 165: ...3 107022 14 EN FR26 GLO 0100 Printed in Germany This page has been left intentionally blank ...
Page 201: ...39 107022 14 EN FR26 GLO 0100 Printed in Germany This page has been left intentionally blank ...
Page 205: ...43 107022 14 EN FR26 GLO 0100 Printed in Germany This page has been left intentionally blank ...
Page 207: ...45 107022 14 EN FR26 GLO 0100 Printed in Germany This page has been left intentionally blank ...
Page 208: ...107022 14 EN FR26 GLO 0100 Printed in Germany 46 9 Declaration of Conformity ...
Page 219: ...11 107006 11 EN FR26 GLO 0300 Printed in Germany This page has been left intentionally blank ...
Page 229: ...21 107006 11 EN FR26 GLO 0300 Printed in Germany This page has been left intentionally blank ...
Page 257: ...49 107006 11 EN FR26 GLO 0300 Printed in Germany This page has been left intentionally blank ...
Page 260: ...107006 11 EN FR26 GLO 0300 Printed in Germany 52 9 3 Declaration of conformity ...
Page 340: ...Safety Perimeter Guarding Installation Manual FF SPS4 Series Safety Perimeter Guarding ...
Page 536: ...2 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Page 538: ...4 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Page 542: ...107004 15 EN FR26 ROW 0899 Printed in France 8 This page has been left intentionally blank ...
Page 620: ...86 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Page 624: ...90 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Page 626: ...92 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...
Page 627: ...107004 15 EN FR26 ROW 0899 Printed in France 93 8 CE Declaration of Conformity ...
Page 628: ...94 107004 15 EN FR26 ROW 0899 Printed in France This page has been left intentionally blank ...