background image

69-1464-1

18

Warranty

Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials,
under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If, at any
time during the warranty period, the product is defective or malfunctions, Honeywell shall repair or replace it (at
Honeywell’s option) within a reasonable period of time.

If the product is defective,

(i) return it, with a bill of sale or other dated proof of purchase, to the retailer from which you purchased it, or
(ii) package it carefully, along with proof of purchase (including date of purchase) and a short description of

the malfunction, and mail it, postage prepaid, to the following address:

Honeywell Return Goods
Dock 4 MN10-3860
1885 Douglas Drive North
Golden Valley, MN 55422

This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by
Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the
possession of a consumer.

Summary of Contents for T8001F

Page 1: ...OWNER S GUIDE T8001F T8024F Flush Mount Programmable Thermostat 69 1464 1 ...

Page 2: ... saving energy and allowing you to awake or return home to a comfortable level of heating or air conditioning Direct questions concerning the operation of this thermostat to Honeywell Customer Assistance at 1 800 468 1502 Monday Friday 7 00 a m 5 30 p m Central time Features Program up to four time periods with temperature settings to complement your lifestyle Set different schedules for weekdays ...

Page 3: ...edule 6 Programming Thermostat 7 Setting Current Time and Day 8 Setting Weekday Program 9 Setting Weekend Program 10 Setting Temporary Temperature Hold 13 Setting Indefinite Temperature Hold 13 Operating Thermostat 13 Setting SYSTEM and FAN Switches 13 Minimum Off Timing 14 Troubleshooting 15 Warranty 18 ...

Page 4: ...UE PM M18613 HOLD KEY SET TEMPORARY TEMPERATURE HOLD INCREASE KEY PROGRAM TIME AND TEMPERATURE SET TEMPORARY TEMPERATURE HOLD SELECT KEY CURRENT SETPOINT CHANGE DAY AND TIME PROGRAM SELECTIONS DECREASE KEY PROGRAM TIME AND TEMPERATURE SET TEMPORARY TEMPERATURE HOLD SYSTEM SWITCH FAN SWITCH ...

Page 5: ...rogram schedule to plan your program Fill in the weekday and weekend times and temperatures you desire If you decide not to program the thermostat it uses the preprogrammed time and temperature settings in Table 1 Table 1 Preprogrammed Time and Temperature Settings Period Time Heat Setpoint Cool Setpoint Wake 6 00 AM 70 F 21 C 78 F 26 C Leave 8 00 AM 62 F 17 C 85 F 29 C Return 6 00 PM 70 F 21 C 78...

Page 6: ...ime Heating Temperature Cooling Temperature Wake ________ ________ ________ Leave ________ ________ ________ Return ________ ________ ________ Sleep ________ ________ ________ Wake and Return start times should include extra lead time based on outside temperature and equipment response time to give your equipment a head start to heat or cool the house The temperatures cannot be set any higher than...

Page 7: ... temp erature and your equipment response time to give the equipment a head start to heat or cool the house before you get up This will be a higher temperature during heating season and a lower temperature during cooling season Leave is the time period you can set for an energy saving temperature while you are away at work or school This will be a lower temperature during heating season and a high...

Page 8: ...fingertip or similar blunt tool Sharp instruments like pens and pencil points can damage the keyboard Setting Current Time and Day 1 To set current time press Select twice Press or to set current time While setting the current time the word SET is displayed 2 To set day of week press Select again Press or to set current day To use the preprogrammed time and tempera ture see Table 1 press Hold to e...

Page 9: ...ight side of the display when setting the program temperature 3 Wake a Press Select Press or to set Wake time b Press Select Press or to set Wake temp erature 4 Leave a Press Select Press or to set Leave time b Press Select Press or to set Leave temp erature 5 Return a Press Select Press or to set Return time M18570 SET M12625C SET M18566 SET M12627B SET M18567 SET ...

Page 10: ...p a Press Select Press or to set Sleep time b Press Select Press or to set Sleep temp erature Setting Weekend Program 7 Wake a Press Select Press or to set Wake time b Press Select Press or to set Wake temp erature M12629B SET M18568 SET M12631C SET M18569 SET M12633C SET ...

Page 11: ...t Leave temp erature 9 Return a Press Select Press or to set Return time b Press Select Press or to set Return temp erature 10 Sleep a Press Select Press or to set Sleep time b Press Select Press or to set Sleep temp erature M12637B SET M18550 SET M18554 SET M12635B SET M12639C SET M18552 SET ...

Page 12: ... setting NOTE The temporary temperature setting remains in effect until the next program period To cancel press Hold twice Setting Indefinite Temperature Hold The Hold key allows you to indefinitely hold a temperature When Hold is active the letters Hld are displayed continuously Hold can be canceled by pressing the Hold key again 1 Press Hold 2 Press or key to set indefinite temperature setting M...

Page 13: ...mostat controls the heating Slide the SYSTEM switch in the lower right corner of the thermostat to select the desired system setting FAN settings Auto Fan operates with equipment On Fan operates continuously Slide the FAN switch in the lower left corner of the thermostat to select the desired fan setting Heat and Cool Indicators Indicates a call for heat Indicates a call for cool NOTE In the progr...

Page 14: ...e indicates the minimum off time is in effect Minimum Off Timing The thermostat minimum off timer assures that the compressor does not come on again for at least five minutes after it turns off The minimum off timer is triggered when the compressor turns off and when the SYSTEM switch position is changed If the compressor turns off when the setpoint is changed the minimum off timer is ...

Page 15: ... on the wallplate Check if the circuit breaker is tripped reset the circuit breaker Check if the fuse is blown replace the fuse Check if the switch at the equipment is in the Off position set to the On position Temperature settings do not change example cannot set the heating higher or the cooling lower Check that the temperature setpoints are between 40 to 99 F 4 to 37 C ...

Page 16: ...tch at the equipment is in the Off position set to On position Wait five minutes for the system to respond Set SYSTEM switch to Heat Cooling does not come on Check if the circuit breaker is tripped reset the circuit breaker Check if the fuse is blown replace the fuse Check if the switch at the equipment is in the Off position set to On position Wait five minutes for the system to respond Set SYSTE...

Page 17: ...or or is lit but no warm or cool air is coming from the registers Wait a couple minutes after seeing the flame or snowflake and then check the registers System on indicator is flashing Minimum off timer is in effect Wait five minutes until the minimum off timer is complete ...

Page 18: ...efective i return it with a bill of sale or other dated proof of purchase to the retailer from which you purchased it or ii package it carefully along with proof of purchase including date of purchase and a short description of the malfunction and mail it postage prepaid to the following address Honeywell Return Goods Dock 4 MN10 3860 1885 Douglas Drive North Golden Valley MN 55422 This warranty d...

Page 19: ...ODUCT THE DURATION OF ANY IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from st...

Page 20: ... www honeywell com yourhome Home and Building Control Honeywell Limited Honeywell Limitée 35 Dynamic Drive Scarborough Ontario M1V 4Z9 Home and Building Control Honeywell 1985 Douglas Drive North Golden Valley MN 55422 Printed in U S A on recycled paper containing at least 10 post consumer paper fibers ...

Reviews: