background image

69-0444—10

3

T834B; T834C; T834J HEATING-COOLING THERMOSTATS

H1

TEMP. FALL

C1

L1 
(HOT)

L2

1

1

2

2

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.

IN ELECTRIC HEAT APPLICATION, JUMPER 1 AND 2 FOR AUTO FAN IN HEATING.

HEAT RELAY

COMPRESSOR
CONTACTOR

FAN RELAY

FAN SWITCH

ON

AUTO

COOL

OFF

HEAT

COOL

OFF

HEAT

SYSTEM
SWITCH

C1
ANTICIPATOR

H1 
ANTICIPATOR

M2035A

W

2

1

Y

G

R

Fig. 4. Internal schematic and typical hookup for T834C dual fuel model

in a gas- or oil-fired, or central electric heat system.

H1

TEMP. FALL

C1

L1 
(HOT)

L2

1

1

2

2

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND 
OVERLOAD PROTECTION AS REQUIRED.

INSTALL JUMPER BETWEEN W AND Y TERMINALS
 WHEN HEAT RELAY IS NOT USED.

HEAT RELAY

FAN RELAY

FAN SWITCH

ON

AUTO

COOL

OFF

HEAT

COOL

OFF

HEAT

SYSTEM
SWITCH

C1
ANTICIPATOR

H1 
ANTICIPATOR

M1037C

W

O

B

Y

G

R

CHANGEOVER
RELAY (COOL)

CHANGEOVER
RELAY (HEAT)

COMPRESSOR
CONTACTOR

Fig. 5. Internal schematic and typical hookup for T834C in heat pump system with supplementary heat.

Fig. 6. Internal schematic and typical hookup for T834C gas or oil-fired systems and single-stage

heat pump or central electric heat.

H1

TEMPERATURE 
FALL

C1

L1 
(HOT)

L2

1

1

2

2

3

3

4

4

POWER SUPPLY. PROVIDE DISCONNECT 
MEANS AND OVERLOAD PROTECTION 
AS REQUIRED.

JUMPER 1-Y FOR AUTO FAN IN COOLING ONLY.

JUMPER 1-2 FOR AUTO FAN WITH WAND Y.

JUMPER W-Y FOR SINGLE-STAGE HEAT PUMP.

HEAT RELAY

FAN RELAY

FAN SWITCH

ON

AUTO

COOL

OFF

HEAT

COOL

OFF

HEAT

SYSTEM
SWITCH

C1
ANTICIPATOR

H1 
ANTICIPATOR

M11342A

W

Y

B

O

2

G

1

R

CHANGEOVER
RELAY (HEAT)

CHANGEOVER
RELAY (COOL)

COMPRESSOR
RELAY

Summary of Contents for T834B

Page 1: ...ls for fan control RECYCLING NOTICE This control contains mercury in a sealed tube Do not place control in the trash at the end of its useful life If this control is replacing a control that contains mercury in a sealed tube do not place your old control in the trash Contact your local waste management authority for instructions regarding recycling and the proper disposal of this control or of an ...

Page 2: ... the thermostat base See Fig 2 Carefully remove and discard the foam plastic shipping insert that protects the switch and bimetal assembly during shipping 5 Set the adjustable heat anticipator indicator to match the current draw of the primary heating control see Heat Anticipator Setting section 18 2 25 3 5 7 9 M8676 FAN SWITCH TEMPERATURE SETTING LEVER MOUNTING HOLE SYSTEM SWITCH ADJUSTABLE HEAT ...

Page 3: ...LAY IS NOT USED HEAT RELAY FAN RELAY FAN SWITCH ON AUTO COOL OFF HEAT COOL OFF HEAT SYSTEM SWITCH C1 ANTICIPATOR H1 ANTICIPATOR M1037C W O B Y G R CHANGEOVER RELAY COOL CHANGEOVER RELAY HEAT COMPRESSOR CONTACTOR Fig 5 Internal schematic and typical hookup for T834C in heat pump system with supplementary heat Fig 6 Internal schematic and typical hookup for T834C gas or oil fired systems and single ...

Page 4: ...4C with terminal for defrost relay in heat pump system Fig 9 Internal schematic and typical hookup for T834C in two transformer system H1 TEMP FALL C1 L1 HOT L2 1 1 2 2 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED JUMPER RC AND RH IN ONE TRANSFORMER SYSTEMS HEAT RELAY COOL OFF HEAT COOL OFF HEAT SYSTEM SWITCH C1 ANTICIPATOR M11746 W RH L1 HOT L2 1 FAN RELAY FAN SWITCH ...

Page 5: ...ELAY FAN RELAY COOL OFF HEAT COOL OFF HEAT SYSTEM SWITCH C1 ANTICIPATOR H1 ANTICIPATOR M6108A W Y G R NO FAN SWITCH Fig 10 Internal schematic and typical hookup for T834B in standard heating cooling system with no fan switching TEMP FALL C1 L1 HOT L2 1 1 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED COOL RELAY P RELAY FAN SWITCH ON AUTO COOL OFF COOL OFF SYSTEM SWITCH C...

Page 6: ...ired control point on the temperature scale The same lever controls both heating and cooling On models with temperature range stops temperature setting lever can be moved only between the two temperature range stops HEATANTICIPATOR SETTING IMPORTANT The T834 Thermostat has an adjustable heat anticipator and will operate properly ONLY IF THE ANTICIPATOR IS ADJUSTED TO MATCH THE CURRENT DRAW OF THE ...

Page 7: ...ed by the thermostat in both heating and cooling T834J With the system switch set at OFF and the fan switch at ON the fan should run continuously Move the fan switch to AUTO The fan operation is controlled by the thermostat Electric Systems with auto fan in heat Set adjustable anticipator to combined current draw of heating and fan relays Other Systems without auto fan in heat Set adjustable antic...

Page 8: ...t the same setting as the thermometer Remove cover 2 Insert Honeywell part no 104994A Calibration Wrench order separately onto the hex nut under the coil See Fig 13 Holding the setting lever so it does not move turn the wrench clockwise until the mercury rolls to the right end of the tube Remove wrench and replace cover To ensure accurate temperature control do not touch or breathe on bimetal or t...

Reviews: