INSTALLATION INSTRUCTIONS

69-1386-1

T8424D Electronic

Multistage Thermostat

The T8424 Thermostat provides electronic control of 

single-zone, multistage heating and cooling systems. 
First and second stage cooling cycle rates are fixed at 3 

cph. Heating cycle rate is selectable. Temperature 
indication can be set for °F or °C. 

The T8424 Thermostat is powered from the system 

transformer. Batteries are not required because setpoints 
are held permanently by non-volatile memory.

The T8424 includes a thermostat, wallplate (for wiring 

and mounting thermostat) and owner’s guide. 

MERCURY NOTICE

If this control is replacing a control that contains 

mercury in a sealed tube, do not place your old 
control in the trash.

Contact your local waste management authority 

for instructions regarding recycling and the 
proper disposal of an old control containing 

mercury in a sealed tube.

If you have questions, call Honeywell Inc. at 
1-800-468-1502.

INSTALLATION

When Installing this Product…

1.

Read these instructions carefully. Failure to follow 

them could damage the product or cause a hazard-
ous condition.

2.

Check the ratings given in the instructions and on 
the product to make sure the product is suitable for 

your application.

3.

Installer must be a trained, experienced service 

technician.

4.

After installation is complete, check out product 

operation as provided in these instructions.

CAUTION

Electrical Shock or Equipment Damage 
Hazard.

Can shock individuals or short equipment 
circuitry.

Disconnect power supply before installation.

Location

Install the thermostat about 5 ft (1.5m) above the floor in 
an area with good air circulation at average temperature. 

See Fig. 1. Do not install the thermostat where it can be 
affected by:

— drafts or dead spots behind doors and in corners.
— hot or cold air from ducts.

— radiant heat from the sun or appliances.
— concealed pipes and chimneys.

— unheated (uncooled) areas such as an outside wall 

behind the thermostat.

This thermostat is a precision instrument and was 

carefully adjusted at the factory. Handle it carefully.

Mounting Wallplate to Wall

IMPORTANT

Level only for appearance. The thermostat func-
tions normally even when not level.

Mount wallplate, T8424 and the screws provided (see 

Fig. 2) as follows:

1.

Place the wallplate at the desired location on the 

wall.

2.

Pull the thermostat wire through the entrance hole 

on the decorator cover plate, then through the wall-
plate entrance hole.

3.

Select the two mounting holes that best fit the 
application.

4.

Fasten the wallplate to the wall using the anchors 
and screws provided.

5.

After wiring the wallplate, plug the hole to prevent 
drafts from affecting the thermostat; see Wiring 

section.

Summary of Contents for T8424D

Page 1: ...le for your application 3 Installer must be a trained experienced service technician 4 After installation is complete check out product operation as provided in these instructions CAUTION Electrical Shock or Equipment Damage Hazard Can shock individuals or short equipment circuitry Disconnect power supply before installation Location Install the thermostat about 5 ft 1 5m above the floor in an are...

Page 2: ... shape of the terminals permits insertion of straight or wraparound wiring connections either method is acceptable See Fig 4 The T8424 Thermostat is powered through the system transformer and is adaptable to most 24 Vac multistage heating cooling systems Refer to Fig 5 for typical wiring hookups Fig 3 Restrict wiring to shaded area 5 FEET 1 5 METERS YES NO NO NO M11338 M12202A WALL WALL ANCHORS 2 ...

Page 3: ...e heating equipment turns on on most systems When using an electric heat thermostat the fan starts and stops with the heating equipment Slide the FAN switch in the bottom left corner of the thermostat to select the desired fan setting SYSTEM Switch System switch settings control thermostat operation as follows Cool The thermostat controls the cooling system Off Both heating and cooling are off Hea...

Page 4: ... set the F C indication and heat cycle rate 1 If the temperature is displayed in F set the tem perature setpoint to 52 F If the room temperature is displayed in C set the temperature setpoint to 11 C 2 Press the keys simultaneously for more than one second to light all segments on display and to enter installer setup mode When the keys are released a two digit software revision code is dis played ...

Page 5: ...thm C3 Aggressive algorithm can cause overshooting 13 Press the key again Current configuration CC is displayed A typical example is shown but CC varies by model This information is for factory use only Table 1 Heating Cycle Rates for Stage Two Heating a High efficiency furnace bRefer to equipment manufacturer s instructions 14 Press the key to save all changes exit installer setup mode and return...

Page 6: ... Press the key to lower the temperature setting several degrees below the room temperature After approximately five minutes the cooling equipment should start The fan starts and stops with the cool ing equipment 3 Press the key to raise the temperature setting above the room temperature Cooling system should shut down NOTE To bypass the 5 minute delay see the Optional System Checkout section Fan 1...

Reviews: