21
Connecting the DC Power Supply
The connection of an external power supply is required only if the
device is not supplied using POE or POE+.
Warning:
To be in compliance with UL60950 the Tema-Voyager Multi
device must be supplied by a separately certified NEC Class
2 (LPS) power unit.
1. Connect the DC Power supply cable heads onto the
J2
terminal
blocks (use a
∅
3mm slotted screwdriver).
2. Connect the ground wire (EGND).
Figure 7 - Multi - Power supply connections
The
J2
connector is provided of a polarized direct screw connector
with the following connection characteristics:
•
Conductor section AWG min = AWG24 max = AWG16
•
Conductor rigid or flexible min = 0.2 mm
2
max = 1.5 mm
2
Check: Once the DC Power Supply is properly
connected and switched on, the LED9 Green Led (Power
Supply) must be in ON status.