CT87N/CT87K • Owner's Manual
69-1959EFS—02
4
1. Align the slots on the base with tabs on
the thermostat, then push gently until the
thermostat snaps into place.
2. Restore electrical power at the heating/
cooling system, or at the fuse/circuit-
breaker panel.
Move the switch to the proper setting for your
system:
F:
For gas or oil heating systems, leave the
fan operation switch in this factory-set position
(for systems that control the fan in a call for
heat).
E:
Change the switch to this setting for heat
pump or electric heat
systems. (This setting
is for systems that allow the thermostat to
control the fan in a call for heat, if a fan wire is
connected to the
G
terminal.)
E
F
Set fan operation switch (CT87N)
Finish installation
Base
Heating System
Switch 1
Switch 2
Steam or gravity
On
On
High efficiency warm air
Off
On
(90% plus efficiency),
hot water, or heat pump
Gas or oil warm air
Off
Off
(factory setting)
Electric warm air
On
Off
Thermostat
Coverplate
(optional)
Move the cycle rate switches
to the proper setting for your
system (see table below).
Set cycle rate switches