Thor VM2 with with Microsoft Windows Embedded CE 6.0 User Guide
239
Result
The Thor VM2 continues to run and follows the AC/DC power scheme with timers reset
at the time power was connected.
Ignition Control Mode
In Ignition mode, the Thor VM2 is turned On when the ignition switch is activated with
no user interaction required. The ignition input wire must be connected.
Note:
When the UPS battery has been depleted or disconnected (the Thor VM2 is first powered
out of the box, the front panel has been replaced, etc.) power the Thor VM2 manually by
pressing the power button. After the initial power up, the Thor VM2 powers on
automatically when the Ignition Control Mode is enabled and the ignition is turned on.
Thor VM2 is Off and Vehicle Ignition is Off
Conditions
The Thor VM2 is Off and vehicle ignition is Off.
Result
The Thor VM2 remains Off regardless of external power. UPS charging is disabled.
Conditions
The Thor VM2 has external power but vehicle ignition is Off. The Power button is
pressed.
Result
The Thor VM2 boots. Once booted the Thor VM2 follows the Ignition Control/Ignition
Off power scheme with timers reset after the boot completes.
Thor VM2 is Off and Vehicle Ignition is Switched to On
Conditions
The Thor VM2 is Off and vehicle ignition changes from Off to On.
Result
The Thor VM2 boots. Once booted the Thor VM2 follows the Ignition Control/Ignition
On power scheme with timers reset after the boot completes.
Thor VM2 is On and Vehicle Ignition is Switched to On
Conditions
The Thor VM2 is On and vehicle ignition changes from Off (or not present) to On.
Result
The Thor VM2 continues to run and follows the Ignition Control/Ignition On power
scheme with timers reset at the time Ignition switched to Active.
An example of this case would be a Thor VM2 that is running on UPS and is then
mounted on a dock that has truck power and the ignition switch is already On.
Summary of Contents for Thor VM2
Page 1: ...User Guide Thor VM2 Vehicle Mounted Computer with Microsoft Windows Embedded CE 6 0 ...
Page 16: ...4 Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide ...
Page 63: ...Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide 51 ...
Page 64: ...52 Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide ...
Page 288: ...276 Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide ...
Page 310: ...298 Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide ...
Page 352: ...340 Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide ...
Page 385: ...Thor VM2 with with Microsoft Windows Embedded CE 6 0 User Guide 373 Hat Encoding ...
Page 398: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com VM2 CE UG Rev D 9 17 ...