THP2400A1019 COVER PLATE ASSEMBLY
69-2762EFS—02
2
CAUTION
Electrical Hazard.
Can cause electrical shock or equipment damage.
Disconnect power before beginning installation.
Mount Cover Plate
Mount Cover Plate Directly to Wall (See Fig. 2)
1.
Pull the wires through the wire hole on the cover plate and wall plate.
2.
Position the cover plate and wall plate on the wall with the arrows pointing up. Level the wall plate for
appearance only.
3.
Use a pencil to mark the mounting holes for your thermostat.
4.
Remove the cover plate and wall plate from the wall and drill two 3/16-in. holes in the wall (if drywall) as
marked. For firmer material such as plaster, drill two 7/32-in. holes. Tap the wall anchors (provided with
the thermostat) into the holes, until the anchor collar touches the wall.
5.
Pull the wires through the wire hole on the cover plate and wall plate. Position the cover plate and wall
plate on the wall anchors.
6.
Insert the mounting screws (provided with the thermostat) into the wall anchors. Check leveling, if desired,
and tighten the mounting screws.
Fig. 2. Mount cover plate, wall plate and thermostat directly to wall.
WALL OPENING
WALL ANCHORS (2)
(PROVIDED WITH
THERMOSTAT)
DRILLED HOLES (2)
WALL
MOUNTING SCREWS (2)
(PROVIDED WITH
THERMOSTAT)
M34259
WIRE
WIRE HOLE
COVER PLATE
MOUNTING HOLES (2)
THERMOSTAT
WIRE HOLE
WALL PLATE