5a Wire single-stage equipment
1. Disconnect the R wire from your heating/cooling system’s terminal block.
2. Connect the R wire to the Rc terminal on the
THERMOSTAT
end of the wire saver.
3. Disconnect the W wire from the heating/cooling system; connect it to W on the
THERMOSTAT
end of the wire saver.
4. Disconnect the G wire; connect it to K on the
THERMOSTAT
end of the wire saver.
5. Disconnect the Y wire; connect it to C on the
THERMOSTAT
end of the wire saver.
6. Connect stripped ends of the included wire bundle to the terminals labeled
EQUIPMENT
on the wire saver in this color order:
a. Connect red to Rc
b. Connect yellow to Y
c. Connect green to G
d. Connect blue to C
e. Connect white to W
7. Connect the other set of stripped ends to the terminals on your heating/cooling system
following the same color order.