Cleaning
On an annual basis, maintenance is required to ensure TrueDRY runs at peak efficiency.
TrueDry DR65 Dehumidification System 69-2089EFS—12
11
1
2
3
4
Unplug TrueDRY DR65 before beginning
service. Press down on the quick-
release button and lift the duct collar.
Remove duct collar to access filter.
Remove filter (50049537-005) and
replace with new filter.
5
When service is complete, initiate a
call for dehumidification and check
that the compressor and fan activate.
If using the VisionPRO IAQ or TrueIAQ
controls, reset maintenance remind-
ers.
Check the drain connection and drain
line to ensure it is clear of debris and
sludge. Ensure all hose connections
are secure once maintenance of the
drain lines is complete.