Zone Panel Professional Installation Guide

HZ221 TrueZONE

69-2200-01

Summary of Contents for TrueZONE HZ221

Page 1: ...Zone Panel Professional Installation Guide HZ221 TrueZONE 69 2200 01 ...

Page 2: ...h this product please visit http yourhome honeywell com or call Honeywell Zoning Hotline toll free at 1 800 828 8367 U S Registered Trademark Patents pending Copyright 2008 Honeywell International Inc All rights reserved Specifications and Accessories 1 Installation 2 Wiring 3 Operation 5 Warranty 6 ...

Page 3: ...10D TH6220D TH8220U TH8321U YTH9421C Note These thermostat models all have different four digit suffixes All versions of the model numbers listed above will work with the applications they re listed for Table 2 Recommended Dampers Type Honeywell Damper Round Rectangular Zone Spring open power closed ARD ZD Zone Power open power closed MARD RRD For recommended dampers call the Honeywell Zoning Hotl...

Page 4: ...only 1 DATS M28164 SUPPLY DUCT RETURN DUCT BYPASS DAMPER ZONE PANEL DUCT MOUNT ZONE PANEL WALL MOUNT ARD DAMPERS DATS ALTERNATE LOCATION Separate the zone panel cover from the base and use the base as a template to drill mounting holes Attach the base to the wall stud roof truss or duct with appropriate screws not included 2 Use two screws for attaching to a stud or roof truss or four screws for d...

Page 5: ...a cable tie M24743 ZONE 2 THERMOSTAT M28234B R C E AUX Y G O B L ZONE 2 DAMPER THERMOSTAT M1 M4 M6 R C E AUX Y G O L Wiring must comply with applicable codes ordinances and regulations Install dampers using instructions provided with dampers Connect dampers to zone panel NOTE Multiple dampers can be wired in parallel 4 M28235 ARD OR ZD DAMPER SPRING OPEN POWER CLOSED ZONE 2 DAMPER M1 M4 M6 R ZONE ...

Page 6: ...24 VOLT TRANS C R Y E C R REVERSING VALVE M27339 R C E Aux Y G O B DS BK L AIR HANDLER FAN RELAY AUX HEAT HEAT PUMP G Y 24 VOLT TRANS C R Y E C R REVERSING VALVE ZONE 2 THERMOSTAT ARD OR ZD DAMPER SPRING OPEN POWER CLOSED PURGE OVERRIDE EQUIPMENT M4 OPEN M6 CLOSED M1 COMMON M1 M4 M6 R C E AUX Y G O L THERMOSTAT R C E AUX Y G O B L RRD OR MARD DAMPER POWER OPEN POWER CLOSED M1 M4 M6 R C E AUX Y G O...

Page 7: ... EM HEAT Solid when in Em Heat mode HZ221 2 Zones 2H 1C LED Status Heat LED Heating Mode Flashing Heat LED High Limit Cool LED Cooling Mode Flashing Cool LED Low Limit Purge LED Purge Mode Flashing Purge LED Sensor Failure Fan LED Fan On Zone LEDs Green Open Red Closed Flashing Short Zone Names Zone 1 _______________________ Zone 2 _______________________ Technical Support 1 800 828 8367 Customer ...

Page 8: ...r air quality and zoning products with a date code of 0452 or earlier twenty four 24 months from date of installation unless specified other wise Variable frequency drive devices VFD and accessories new products for thirty six 36 months and factory refurbished drives for twelve 12 months from date of installation when start up and commissioning is performed by Honeywell VFD Authorized and trained ...