Security (cont'd) 

 

12 

How to Display Faults 

The Display Faults function is used when you see a “Not Ready Fault” message and want to determine where the fault is and 

what type of fault it is.  To display faults do the following: 

ICON ACTION 

 

NOTES 

 

  

 

1.

 

From the "Security" screen, press the 

DISPLAY FAULTS

 icon.  

 

2. 

If the fault cannot be corrected, you may 

choose to bypass a zone by pressing the zone 

and highlighting it and then pressing the 

BYPASS SELECTED 

icon.

 

A listing of faulted and/or bypassed zones is displayed. 

 

As applicable, take corrective action such as closing a window or door to 
correct the fault. 

Show Zones Icons 

Distressed Zones Icons 

 

Clear 

Bypasses 

 

 

Refresh 

Data   

 

  Bypass 
Selected   

 

 

 

 

Bypass All 

 

 

  istressed 

Zones 

 

 

Alarm

 

 

 

Troubles  

 

 

Faults 

 

Bypass 

Zones 

 

Low 

Battery

 

 

 

All 

How to Bypass Zones 

The Bypass function is used when you want to arm the system with one or more zones left open. Bypassed zones are unprotected 

and do not cause an alarm when violated while the system is armed.  

 

 

Residential systems do not allow you to bypass fire, carbon monoxide or emergency zones. On commercial fire systems, a specified user 
may be allowed to bypass fire, carbon monoxide and system zones if the user was enabled by your system installer. 

  Limits apply as to how many zones can be bypassed at one time. These limits are ten zones on residential systems and five zones on 

commercial systems.

 

To bypass zones do the following: 

 

4.  Highlight the zone(s) to be bypassed and 

press the 

BYPASS SELECTED 

icon. 

5.  Enter the 4-digit user code. 

Note: If zones have already been bypassed, the top of this screen indicates 
Ready Bypass”.  

The screen is displayed with the instructions "To Bypass Zones, Enter 
Code
". 

ICON ACTION 

 

NOTES 

 

 

1.  From the “Home” screen, press the 

SECURITY 

icon.   

2.  Press the 

MORE CHOICES

 icon.  

Note: If any zones are bypassed or faulted, a Display Faults icon is also 
displayed on this screen. 

While the keypad is requesting and receiving the zone data from the control 
panel, the screen displays "Please Wait!". Then the zones, along with their 
current status, are displayed.  

3.  Press the 

SHOW ZONES

 icon. 

Summary of Contents for Tuxedo Touch Series

Page 1: ...T Tu ux xe ed do o T To ou uc ch h S Se er ri ie es s H Ho om me e A Au ut to om ma at ti io on n S Sy ys st te em m User Guide 800 08091V3 4 13 Rev A ...

Page 2: ... Mode 9 SECURITY 10 Introduction to Security System Operation 10 How to Arm the System 11 How to Arm Multiple Partitions 11 How to Display Faults 12 How to Bypass Zones 12 How to Clear Bypassed Zones 13 How to Disarm the System 13 To disarm Multi Partitions do the following 14 How to Check the Status of Other Partitions 14 Fire and Carbon Monoxide Alarm Operation 14 In Case of Fire Alarm 15 Silenc...

Page 3: ...udio Setup 18 Operating Modes 18 Language Selection if applicable 18 Adjust the Screen Timeouts 19 Clean Screen 19 Routine Care 19 Web Server Hosting 20 IP Setup 20 MULTI MEDIA 22 Voice Messages 22 Video Audio Setup 23 Picture Setup 23 Camera Setup 24 USER SETUP 26 Authority Levels 26 How to Add a User 26 How to Add an Existing User to a Second Keypad 27 How to Delete a User 27 How to Edit a User ...

Page 4: ... Wave Devices 35 Remove Delete a Door Lock 35 Remove Delete a Honeywell Thermostat 36 Remove All Z Wave Devices 36 Abort a Z Wave Action 36 Scene Setup 37 Create a Room 39 Setting a Secondary Keypad Controller 39 Updating Controllers Keypads with New or Removed devices 40 Removing a Secondary Controller Keypad 40 Z Wave Troubleshooting 40 Remote Services 41 Compatible Devices 43 IMPORTANT NOTES 44...

Page 5: ...curity system is disarmed Cameras control and view up to four cameras in quad view at the same time from any web enabled device In addition this system offers you burglary protection and may provide fire carbon monoxide and emergency protection To realize the full potential of the system it is important that you feel comfortable operating it Your system may consist of one or more of the following ...

Page 6: ...y Your system installer may have changed the actual background and icons shown on your Home screen Memory Card Insertion Insert the memory card SD SDHC Card as shown Tips for proper memory card handling Avoid touching the contacts on the card Quit the slide show video application before removing the memory card 6280 004 V0 INSERT CARD Weather Forecast The Weather forecast is displayed on the Home ...

Page 7: ...Allows user to display personal photos in a slide show format Panic Displays Emergency functions as programmed by the installer Note This icon is displayed and active on all screens except while in the Clean Screen mode during an LCD Display test in Diagnostics and from the Video and Camera screens Message Record and retrieve Voice Messages Voice Status Allows user to hear system status Back Rever...

Page 8: ... Expander Failure The system has a failure in an expansion module Low Battery The system battery that powers the system during an AC power loss is low LRR Supervision Failure The Communication Device used to communicate with the central station has a supervision failure Max Attempts Exceeded The system has exceeded the maximum attempts to communicate with the Central Station Pager Failure The syst...

Page 9: ...Press to reset keypad ON System is armed OFF System is not armed ARMED RED LED READY GREEN LED ON System is disarmed and ready to arm OFF System is armed or disarmed but not ready If disarmed faults or troubles are present MESSAGE YELLOW LED SD SDHC CARD Slot NOTE If the Screen Blackout feature EN50131 Display is enabled see below the keypad returns to the Home screen and the Armed and Ready statu...

Page 10: ...es Yes set for Away or Stay Mode No set for Instant or Maximum Mode Yes Yes set for Away or Maximum Mode No set for Stay or Instant Mode See Night Mode note below Note Night Mode on Residential Panels Only arms all perimeter zones plus all zones listed in Zone List 5 Important On Commercial systems Away Auto Stay mode is shown as Away mode with all zones monitored However some interior zones may n...

Page 11: ... the last 10 seconds of Exit Delay When exit delay time expires the screen automatically changes to indicate the system is Armed Note For CP 01 installations Maximum Mode cannot be used How to Arm Multiple Partitions Note Some systems may not have multiple partitions and the Arm Multi Partitions icon may not be displayed To arm multiple partitions ICON ACTION NOTES 1 From the Home screen press the...

Page 12: ...rm when violated while the system is armed Residential systems do not allow you to bypass fire carbon monoxide or emergency zones On commercial fire systems a specified user may be allowed to bypass fire carbon monoxide and system zones if the user was enabled by your system installer Limits apply as to how many zones can be bypassed at one time These limits are ten zones on residential systems an...

Page 13: ...under is on DO NOT enter the premises but call the police from a nearby safe location If you return to your home or business after an alarm has occurred and the main sounder has shut itself off the keypad beeps rapidly upon entering indicating that an alarm has occurred during your absence LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location The system may be disarmed using either ...

Page 14: ... Note that only those partitions authorized and programmed by the installer can be accessed in this manner To check the status of other partitions perform the following ICON ACTION NOTES 1 Press the SECURITY icon 2 Press the Current Partition icon lower edge of the screen in this case it displays P1 H unless changed by installer This screen displays the available partitions and their current statu...

Page 15: ...r Commercial Systems Press the CLEAR icon followed by your code The system attempts to clear the alarm from memory If NOT successful i e smoke in the detector the Security screen is displayed and the Display Faults icon displays a Not Ready Fault c Press the DISPLAY FAULTS icon on the Arming screen The faulted fire carbon monoxide zone is displayed d Press the CLEAR icon and then enter your code T...

Page 16: ... features not supported by the keypad refer to your Control Panel User Guide Console Emulation Mode Console Emulation Mode allows you to use a keypad interface just as you would a regular system keypad All commands shown in Console Emulation mode can also be executed from a standard alpha keypad Notes It is recommended that you do not use the Console Emulation Mode to enter GOTO commands Unsatisfa...

Page 17: ...l Events icon is pressed and more than 100 events exist the Next and Previous icons are displayed showing the next 100 or previous 100 events How to Send Emergency Messages An emergency message for fire panic or medical can be sent to the central monitoring station from the Emergency screen The Emergency screen can be accessed by activating the PANIC Icon located on the lower right corner of the s...

Page 18: ...ndow is open Voice Mode Keypad voice annunciates whenever a change in system status occurs Voice Chime The chime mode and voice mode are in effect with the chime beeps followed by voice annunciation Access the Operating Modes screen as follows ICON ACTION NOTES 1 From the Setup screen press the Disp Audio Setup icon 2 Enter your Authorized Code if required If the Chime Mode and Voice Mode are both...

Page 19: ...be changed Clean Screen With the exception of normal cleaning the keypad is maintenance free Clean the touch screen as follows ICON ACTION NOTES 1 Press the Setup icon 2 Press the Disp Audio Setup icon 3 Enter your Authorized Code if required 4 Press the CLEAN SCREEN icon to disable the keypad for 30 seconds 5 Press Continue to disable the touch screen 6 Press Cancel to exit At the Touch Screen Di...

Page 20: ... icon from the Home screen b Press the IP Setup icon the IP Setup screen displays the IP Address and Default Gateway Address of the router c Press the Refresh button the IP information will automatically update This may take up to 60 seconds d Press Apply the keypad will save the information and reset After proper setup the IP Address is displayed on the Home screen Enter the IP Address displayed ...

Page 21: ...ired information Use the Shift key for capital letters Use the BS Backspace key to make corrections Press OK A pop up window displays the message Settings Changed Remember new settings Select Yes to save the settings Select No to cancel Account Setup Account setup provides a browser log on page for each user for higher security when viewing from a web enabled device or PC on a different sub net To...

Page 22: ... Memo message is displayed above the message list window 3 Press the Stop icon when you are done recording the message The message indicator flashes and the message is listed in the message list window To record additional messages repeat steps 2 and 3 To exit press the BACK or HOME icon To retrieve a voice message 4 Select from the message list and then press the Play Message icon Use the Pause b...

Page 23: ...deo display Video Icons Play Pause Full View Repeat Stop Press these icons to Play Pause view a Full View Stop or Repeat the video Press the Full View icon to view a video in full screen To exit Full View mode while a video is playing press anywhere on the screen Picture Setup The Picture feature allows the user to display up to 1000 personal photos on the keypad and can be accessed by pressing th...

Page 24: ...w feature If using existing mounted cameras go to Step 4 below If this is a first time setup scan configure the cameras prior to mounting and then follow the steps below To set up a camera do the following ICON ACTION NOTES 1 Connect an Ethernet cable to the back of your camera LAN connect the opposite end to the Ethernet port on your router 2 Apply power to the Camera It may take a few seconds fo...

Page 25: ...te Address Password RTSP Port HTTP Port if known On the Camera Configuration screen enter the appropriate information Name Model User RTSP Path Resolution Frame Rate Address Password RTSP Port HTTP Port if known Enter the appropriate Wireless Settings SSID Network Type Channel No Security System Authentication Type WEP Encrypt Pass Phrase and WEP Key if applicable For WPA PSK TKIP WPA PSK AES and ...

Page 26: ...the equivalent authority level name found in your alarm system manuals The authority levels that can be assigned are as follows Authority Level Functions Equivalent System Name Residential Systems Commercial Systems Master Can perform all security functions add delete users in assigned partition program scheduled events and change partition master code Partition Master Level 1 Master Normal Perfor...

Page 27: ...o Add a User above The second keypad will automatically update the user information Press Save How to Delete a User ICON ACTION NOTES 1 Select the User you want to delete 2 Press the DELETE USER icon 3 Enter your Authorized code 4 Press the appropriate icon The Confirm Delete screen is displayed Three selections are available add a user edit a user or delete a user The authorized code for deleting...

Page 28: ...nters into the Safe Mode If you answer with No the keypad tries to communicate with the panel again After 3 consecutive times of receiving no response the keypad enters the Safe Mode automatically Note Use care when providing the Yes or No response Pressing the screen outside the prescribed area may cause the background to come to the front If this occurs the Yes No message that disappeared times ...

Page 29: ...ek and time chosen 4 Set the Start DST time and then the End DST time by pressing the Month Weekend and Hour that you want DST to start 5 APPLY saves the settings Make sure DST On is checked to enable this feature Setting Current Time and Date To set the current time do the following ICON ACTION NOTES 1 Press the Time Date Setup icon enter an Authorized Code 2 Press the Month arrow and select the ...

Page 30: ...bration Test and Z Wave Test Performing Diagnostic Tests Select any diagnostic test from the Diagnostics screen by pressing the associated Test icon All or any individual test may be run when you access the Diagnostics screen however each test must be performed one at a time At any time when a test is not being performed you can press back to return to the previous screen or home to return to your...

Page 31: ...follow the handheld controller manufacturer s instructions The pop up message disappears and controllers have shifted successfully Z Wave devices can now be enrolled from this controller Note The Z Wave Primary Controller Shift to Secondary icon is inactive when the Tuxedo Touch becomes the secondary controller The Shift is completed when the warning window disappears 6 Shift the Tuxedo Touch back...

Page 32: ... arm the system in one of five arming modes Away Stay Instant Night Maximum Apply accepts the setting Back cancels your selection Output Setup Function The Output Setup screen displays output selections A maximum of 18 outputs can be enabled or disabled on the Output screen To set the Output Setup function press the System Setup and Advanced Setup icon and then do the following ICON ACTION NOTES 1...

Page 33: ...and property protection Enroll a Light Switch or Outlet Module Install a Z Wave Light Switch or Outlet module as described below ICON ACTION NOTES 1 At the Tuxedo Touch Keypad a Press the Automation icon from the Home screen and then press the Z Wave Setup icon to display Z Wave Device Management screen b Press the Z Wave Enroll Add icon 2 At the device Module a Press the Function Key on the devic...

Page 34: ...ock Enroll a Honeywell Thermostat Install Honeywell Thermostat according to the manufactures instructions Device should be mounted in the final location and tested before adding it to the system Note Honeywell is not responsible for property damages due to improper setting of the thermostat modes To enroll a Honeywell Thermostat into a Z Wave network do the following ICON ACTION NOTES 1 At the Tux...

Page 35: ...creen press the Automation icon and the Z Wave Setup icon The Z Wave Device Management screen is displayed 2 Highlight the device to remove and press the Z Wave Remove Delete icon 3 On the door lock press the Function Key to remove the device from the keypad Z Wave Remove Delete clears the node from the keypad and resets device to the default setting Notes If the device is not removed or to remove...

Page 36: ... default setting Note To remove a defective device refer to the Z Wave Troubleshooting section Remove All Z Wave Devices ICON ACTION NOTES 1 At the Tuxedo Touch Keypad a Press the Automation icon from the Home screen and then press the Z Wave Setup icon to display the Z Wave Device Management screen b Press the Z Wave Reset icon to delete all devices from the controller c Press the Continue or Can...

Page 37: ...ion set to occur prior to a trigger event See example below Example Turn the lights on when the system is disarmed only at night Condition only at Night Set the TIME condition enter the Start Time and End Time Trigger when the system is Disarmed Set the Trigger to SECURITY System Disarm Action Turn the lights ON Set the Action to LIGHT ON ICON ACTION NOTES 1 At the Tuxedo Touch Keypad a Press the ...

Page 38: ...e Region selected in the Weather Forecast section and requires internet access for accuracy Or press the Timer button to limit the scene to execute only from within a specified time window and press on the hour minutes displayed to enter the desired time on the data entry keyboard Press on AM PM to change the setting To set a security mode press the SECURITY button and select DISARM AWAY STAY NIGH...

Page 39: ...e or delete a room Room Setup Icons Delete Edit Add Save Setting a Secondary Keypad Controller After all Z Wave devices have been enrolled into the Primary Keypad Controller the device information can be downloaded to a Secondary Keypad Controller Keep the controllers within 10 feet of each other apply power to the Secondary Controller and do the following ICON ACTION NOTES 1 At the Primary Contro...

Page 40: ...d and the Secondary Controller keypad will revert back to the Primary Controller Z Wave Troubleshooting PROBLEM SOLUTION Cannot add new device Make sure the Z Wave device is within range of the Tuxedo Touch keypad You may need to move the device closer to the keypad Refer to the Z Wave device Instruction Guide for proper range Device is within proper range but still is not enrolled 1 At the Tuxedo...

Page 41: ...otal Connect Scenes created in Tuxedo View Edit Scenes View Edit Scenes Total Connect yes yes no no Tuxedo yes no yes yes NOTE For troubleshooting purposes Total Connect server information including IP addresses can be viewed on the Total Connect Server Setup screen by pressing the TC Server Info button see next page Remote Services Setup NOTE If used for Remote Services Tuxedo Touch should not be...

Page 42: ...een created in Total Connect 1 From the Home screen press the Automation and Scene Setup icons then press the Remote button The screen displays a list of scenes created in Total Connect NOTE The Local button allows you to view a list of scenes created in Tuxedo 2 To control a Remote scene select the desired scene then click the appropriate action ex Run Enabling Devices for Total Connect 1 From th...

Page 43: ...ck Yale Real Living Touchscreen Lever Lock Yale Real Living Push Button Deadbolt Lock Yale Real Living Touchscreen Deadbolt Lock Schalge Link Deadbolt Lock Schlage Link Lever Lock Kwikset Smartcode Lever Lock Kwikset Smartcode Deadbolt Lock Thermostats Honeywell ECC Wayne Dalton Zwave Thermostat Trane Zwave Thermostat Appliance HomeManageable Appliance Module Wayne Dalton Small Appliance Module GE...

Page 44: ...etc between the remote and the destination device will reduce the maximum range of 100 feet by approximately 25 30 Brick tile or concrete walls block more of the RF signal than walls made of wooden studs and drywall Wall mounted Z Wave devices installed in metal junction boxes will suffer a significant loss of range approximately 20 since the metal box blocks a large part of the RF signal WARNING ...

Page 45: ...eway is a computer and or software used to connect two or more networks which translates information from one network to the other A Gateway IP Address is the IP address for the gateway IP Address A unique number consisting of four parts separated by periods assigned to every computer workstation connected to the Internet Home Screen The screen that is normally displayed on the keypad when entries...

Page 46: ...a installed Reorient the receiving antenna until interference is reduced or eliminated Move the radio or television receiver away from the receiver control Move the antenna leads away from any wire runs to the receiver control Plug the receiver control into a different outlet so that it and the radio or television receiver are on different branch circuits Consult the dealer or an experienced radio...

Page 47: ...ONE FOR ANY i CONSEQUENTIAL INCIDENTAL INDIRECT SPECIAL OR PUNITIVE DAMAGES ARISING OUT OF OR RELATING IN ANY WAY TO THE PRODUCT AND OR FOR BREACH OF THIS OR ANY OTHER WARRANTY OR CONDITION EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER EVEN IF THE LOSS OR DAMAGE IS CAUSED BY SELLER S OWN NEGLIGENCE OR FAULT AND EVEN IF SELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSSES ...

Page 48: ...Ê800 08091V3RŠ 800 08091V3 4 13 Rev A 2 Corporate Center Drive Suite 100 P O Box 9040 Melville NY 11747 Copyright 2013 Honeywell International Inc www honeywell com security ...

Reviews: