Automation (cont'd)
38
Scene Rules
•
Triggers and Conditions include: Time setting, Security mode, Thermostat setting, Door status and Zones.
•
Actions include: Security mode, Lights on/off, Thermostat settings, and Door Lock status.
•
Each Trigger event can have up to 3 Actions.
•
A Trigger event and Condition cannot be the same (i.e., if setting a Trigger event for SECURITY, you cannot set a SECURITY
Condition).
•
A total of 10 Scenes can be created.
Note
: Determine if you need a Condition. The Condition is a ‘pre-condition’ set to occur prior to a trigger event. See example
below.
Example
:
Turn the lights on, when the system is disarmed, only at night.
(Condition)
… “only at Night”
...Set the
TIME
condition (enter the
Start Time
and
End Time
).
(Trigger) …
…when the “system is Disarmed”
…Set the Trigger to
SECURITY:
System
Disarm
.
(Action) …
Turn the “lights ON” …
… Set the Action to
LIGHT:
ON
.
Scene Setup Options
Options for adding a Condition (if needed) – After each selection press SAVE!!!
In the “Condition” box, press the
Add
icon.
To set the time, press the
TIME
button:
“
Set the occurrence”
to
Repeated
, or
Once. I
f “Repeated” was selected, choose the desired days of the
week; if
ONCE
was selected
Enter Date.
The Time can be set to edeute automatically at Sunrise or Sunset by pressing the
Sunrise/Sunset
option. Note: The Sunrise/Sunset feature is dependent on the “Region” selected in the “Weather Forecast” section and requires internet access
for accuracy. Press the
BY CLOCK
button (to limit the scene to execute only from within a specified time window) and press on the
“hour/minutes” displayed, to enter the desired time on the data entry keyboard. Press on
AM/PM
to change the setting.
To set the security mode, press the
SECURITY
button and select:
DISARM
,
AWAY
(triggers upon arming away),
STAY
,
NIGHT,
AWAY SECURED
(triggers when exit delay has expired)
and
ALARM.
To set the thermostat settings, press the
THERMOSTAT
button and select a
Thermostat Device
from the drop down menu. Use the
ABOVE
and
BELOW
buttons to increase/decrease the temperature or press the
Temperature Value
box and enter 2 digits for the desired temperature.
Note:
Test thermostats first to ensure proper function in the Scene feature.
To set the door lock status, press the
DOOR
button and select a
Door Device
from the drop-down menu (see notes below). Select
LOCKED
or
UNLOCKED
.
To set the zones, press the Zones button and select a zone from the drop-down menu. Select
Restore
,
Alarm
or
Fault
.
Note: Do not use zone
Restore
option in the Condition field.