PRODUCT DATA
68-0045-3
® U.S. Registered Trademark
Copyright © 2001 Honeywell • All Rights Reserved
V8200
Combination Gas Controls
APPLICATION
The V8200 Continuous Pilot Combination Gas Controls are
used in gas-fired, standing pilot appliances. The include a
manual gas valve, safety shutoff, single automatic operator
and a pressure regulator.
FEATURES
• Add ECO switch where codes call for dual safety
shutoff.
• For use with 24 Vac heating appliances that burn
natural or liquefied petroleum (LP) gas.
• Capacity rated at 130 feet
3
/hour at 1 inch wc pressure
drop (3.7m
3
/hr at 0.25 kPa). Maximum regulated
capacity is 200 feet
3
/hour (5.7 meter
3
/hour). Minimum
regulated capacity is 20 feet
3
/hour (.6 meter
3
/hour).
• Diaphragm-operated automatic valve opens under
control of the regulator and closes if gas or power
supply is interrupted.
• Three-position manual gas control knob has ON, OFF,
and PILOT positions.Separate reset button must be
held down to permit gas flow while lighting pilot; can
be pushed down only in PILOT positions. All
adjustments, wiring connections and pilot outlet are
accessible from the top of the gas control.
• Compact size.
• Straight-through body pattern right angle adapters
available for inlet and outlet.
• 1/2 inch inlet and 1/2 inch outlet; adapters available
for 3/8 or 3/4 inch inlet or outlet.
• Adjustable servo regulator effectively maintains
almost constant gas output pressure under wide
fluctuations in gas supply pressure. Factory setting
does not need readjustment for specific rating of
furnace.
• Inlet and outlet screens included.
• Pilot filter included.
• Wiring terminal block color-coded beige to identify
standing pilot models.
• May be installed at any angle between 0 and 90 degrees
from the upright position, including vertically.
• 1/4 inch quick-connect terminals for electrical
connections.
• 0°F to 175°F (-18°C to +79°C) temperature range
standard; -40°F to +175°F (-40°C to +79°C) available.
• Inlet and outlet pressure taps included; both taps
accessible from top of gas control.
• Standard, slow, and step-opening models available.
• ECO connector included with some models: also
available as accessory.
• Natural to LP gas conversion kit included with
standard and slow-opening models.
• LP to natural gas conversion kit available for standard
and slow-opening models.
Contents
Application .......................................................................
Features ...........................................................................
Specifications ...................................................................
Ordering Information ........................................................
Installation ........................................................................
Startup and Checkout ......................................................
Maintenance .................................................................... 11
Operation ......................................................................... 12
Service ............................................................................. 15
Instructions to the Homeowner ........................................ 15