PRODUCT DATA

60-2311-11

V9055A,D Modulating Fluid Power 

Gas Valve Actuator

APPLICATION

The V9055 Gas Valve Actuator in combination with a V5055, 

VE5000

a

 or V5097 Gas Valve provides modulating control of 

the gas supply to commercial and industrial burners.

a

VE5000 is a European manufactured and approved valve for 

European use only.

FEATURES

• Actuator opens the valve to the low-fire position when 

energized. Actuator then modulates to meet firing rate 

controller (Series 90) demand.

• Actuator is equipped with an integral shaft that may be 

used to drive a combustion air damper in unison with the 

gas valve.

• The V5055 or V5097 Gas Valve includes a yellow SHUT 

indicator. The actuator includes a red OPEN indicator. The 

indicators provide constant visual indication of valve 

position.

• Actuator can be used with all VE5000

a

, V5055 or V5097 

Valve models; however, the V5055B or V5097B with 

characterized guide is recommended for optimum control 

and low-fire repeatability.

• Ambient temperature range for 60 Hz models is -40°F to 

125°F (-40°C to 53°C). Ambient temperature range for 50 

Hz and 50/60 Hz models is -10°F to 125°F 

(-23°C to 52°C).

• Auxiliary 1/2 hp rated switch is available for field 

installation.

• Integral damper shaft provides a maximum of 20 lb 

(9 kg) of force.

• Valve and actuator may be mounted in any position.
• Model is available with NEMA 4 (IP54) weatherproof 

enclosure.

• V9055D/V5055C,E and V9055D/V5097C,E combinations 

available with proof-of-closure switch and two valve seals 

(valve seal overtravel interlock) to meet specific code/

standard/insurer requirements.

• Field addable adapter available for 4-20 dc mA control of 

actuator.

• When replacing a V9034 Actuator with a V9055, the V5034 

Valve body must also be replaced with a V5055 or V5097 

Gas Valve.

NOTICE: Per Industry Standards, the actuator is required a 

conduit seal or a cable type that is sealed be installed in a 

device that can result in a flammable liquid flow through a 

conduit or cable to an electrical ignition source in the event 

of a seal leakage or diaphragm failure.

Contents

Application ........................................................................

1

Features ...........................................................................

1

Specifications ...................................................................

2

Ordering Information  ........................................................

2

Installation ........................................................................

4

Wiring ...............................................................................

5

Adjustments ......................................................................

6

Operation ..........................................................................

7

Checkout and Service  ......................................................

7

Summary of Contents for V9055A

Page 1: ...e for 60 Hz models is 40 F to 125 F 40 C to 53 C Ambient temperature range for 50 Hz and 50 60 Hz models is 10 F to 125 F 23 C to 52 C Auxiliary 1 2 hp rated switch is available for field installation Integral damper shaft provides a maximum of 20 lb 9 kg of force Valve and actuator may be mounted in any position Model is available with NEMA 4 IP54 weatherproof enclosure V9055D V5055C E and V9055D...

Page 2: ...capacity curves Table 1 Pressure Ratings of Actuator Valve Combinations a Max Operating Pressure Differential UL or Max Operating Pressure CSA maximum allowable pressure drop from inlet to outlet for proper operation b Max rated pressure UL or Max Close off Pressure CSA maximum pressure that the valve can be exposed to without leak age or damage to the valve c Applies for small body V5097 valves 3...

Page 3: ... 3 32 5 KNOCKOUT FOR1 2 INCH CONDUIT 4 OCTAGON 3 4 19 1 BOLT HOLES 8 ON 3 3 4 95 RADIUS 1 9 32 1 3 16 30 9 3 16 233 27 32 21 5 3 23 32 5 94 5 127 0 3 19 32 91 6 3 4 171 5 3 4 1 1 1 4 1 1 2 2 2 1 2 3 4 VALVE SIZE INCH 11 1 8 11 1 8 11 1 8 11 1 8 11 1 4 11 3 4 11 3 4 14 1 8 2 3 4 2 3 4 2 3 4 2 3 4 2 7 8 3 3 8 3 3 8 5 13 16 8 3 16 8 3 16 8 3 16 8 3 16 8 5 16 8 13 16 8 13 16 11 7 32 5 3 4 5 3 4 5 3 4 ...

Page 4: ...ide down if water is likely to drip on it In this position water can become trapped in the electronics compartment When Installing This Product 1 Read these instructions carefully Failure to follow them could damage the product or cause a hazardous condi tion 2 Check the ratings given in the instruction and on the product to make sure the product is suitable for your application 3 Installer must b...

Page 5: ...er crank arm is used with a NEMA 4 actuator that is exposed to ice or sleet a suitable shield must be installed to prevent ice or sleet buildup The crank arm provides a maximum travel of 2 5 16 in 59 mm For complete installation information refer to the instructions packed with the 7616BR Crank Arm Fig 2 Crank Arm Operation Fig 3 Internal components and connections in V9055 WIRING WARNING Electric...

Page 6: ...n Verify proper operation after servicing ADJUSTMENTS IMPORTANT When using the V9055D with the V5055 V5097C or E two seals Valves match low fire minimum adjust ment to the burner and the application Too low of an adjustment could result in loss of burner flame Also plan to check this low fire adjustment at periodic maintenance intervals Adjust Low Fire Setting The low fire setting is adjustable fr...

Page 7: ...al potentiometer color to color to terminals W R and B on the actuator With the valve energized use the potentiometer to open and close the actuator It should run from the low fire position and to the fully open position If the actuator fails to operate properly replace it 1 Turn off the gas supply at the manual shutoff valve located upstream from the valve s being serviced 2 Shut off all electric...

Page 8: ...ssembly 13 Re attach the wires removed from the actuator termi nals and turn on the electrical power 14 With the gas still off cycle the actuator to check for proper mechanical operation CAUTION Be sure to perform a bonnet seal and seat leak check after installation Be sure to read and follow all instructions that come with the actuators valves seal and bonnet kits Each replacement assembly contai...

Reviews: