Section 5 – Data Field Descriptions
5-11
FIELD
TITLE and DATA ENTRIES
EXPLANATION
1*45
Exit Delay Sounding (partition-
specific)
0
= disable
1
= enable
If enabled, the system produces slow beeping from the keypads during exit
delay and reverts to rapid beeping during the last 10 seconds of the exit delay.
NOTE:
The duration of the beeping is the programmed value of field *10
regardless of which entry/exit zone is used to exit the premises. SIA Guidelines:
Exit Delay Sounding must be enabled.
See page 32 in the
Programming Guide
, “SOUND OPTION”, prompt for
disabling the entry/exit beeps on individual keypads.
1*46
Auxiliary Output Mode
0
= ground start output.
1
= smoke detector reset.
2
= keypad sounds at an auxiliary sounder.
3
= AAV module.
Select the mode for output 1 on the J7 triggers.
NOTES:
Only one of the options may be active within the system.
Option 2 is available in the VISTA-128BP only.
Option 2 applies only to the partition enabled in field *15.
1*47
Chime on External Siren
(partition-specific)
0
= disable
1
= enable
If enabled, the system produces chime annunciation on the external alarm
sounder.
1*48
Wireless Keypad Assignment
0
= none
1-8
= partition number
Select the partition in which RF keypad is used.
1*49
Suppress Transmitter
Supervision Sound
0
= disable
1
= enable
If enabled, no trouble soundings occur on the keypad for transmitter check-in
failures.
Must be
0
for UL.
1*52
Send Cancel If Alarm + Off
(partition-specific)
0
= disable
1
= enable
If enabled, Cancel reports are sent when the system is disarmed after an alarm,
regardless of how much time has gone by.
If disabled, Cancel reports are sent within Bell Timeout period only.
NOTE:
This option must be enabled so Cancel reports are always sent.
1*53
Disable Download Callback
0
= callback required
1
= no callback required
Select whether a callback from the control panel is required for downloading.
Must be
0
for UL installations.
1*55
European Date Format
0
= disable (mm/dd/yy)
1
=
enable (dd/mm/yy)
Select the date format for display in the event log.
1*56
AC 60Hz or 50Hz
0
= 60Hz
1
= 50Hz
Select the frequency for the AC.
Must be set to
0
for U.S. and Canadian installations.
1*57
Enable 5800 RF Button Global
Arm
0
= disable
1
= enable
If enabled, the system arms/disarms in accordance with the button’s user’s
global arming settings.
1*58
Enable 5800 RF Button Force
Arm
0
= disable
1
= enable
If enabled, allows the RF button user to force a bypass of all faulted zones
when arming the system.
NOTE:
When attempting to arm the system, the keypad beeps once after the
button is pressed if any faulted zones are present. The user should then press
the button again within 4 seconds to force-bypass those zones and arm the
system.