INSTRUCTION SHEET

VK41..R/VK81..R series

GAS CONTROLS WITH INTEGRATED GAS/AIR MODULE

FOR COMBINED VALVE AND IGNITION SYSTEM

EN1R--9137 9808R6--NE

APPLICATION

The VK41..R/VK81..R series gas controls with integrated

gas/air module have been developed for application in

domestic appliances with premix or atmospheric burners and

automatic ignition.
The gas/air module is designed to amplify and modulate the

outlet gas pressure by means of a pneumatic link between the

gas and air flow by using the air pressure difference.
For this system, the VK41..R series gas controls have been

designed to have the S4565 series ignition control attached

directly onto the valve.
The combined system then provides programmed safe light

up, flame supervision and regulation of gas flow to the main

burner of the appliance.
The VK41..R/VK81..R series are used in a system context in

conjunction with fan control and a direct spark ignition (DBI)

control.
The VK41..R/VK81..R series are approved in accordance with
european standards.

DESCRIPTION

VK41..R/VK81..R combined gas controls perform all the

functions required to safely regulate gas flow to the main

burner of domestic central heating equipment, warm air

furnaces, back boilers and water heaters.
VK41..R/VK81..R combined gas controls hold a first electric

on/off direct operator for opening the safety valve of class A or

class B according to EN161 and a second electric on/off

servo operator of class B or class C to EN 161.
VK41..R/VK81..R combined gas controls comply with the

additional requirement for class J valves according to EN 161.
The pressure regulator is in accordance with class B

requirement of EN 88.
VK41..R/VK81..R combined gas controls can handle the three

gas families, manufactured gas, natural gas and LP gas.

SPECIFICATIONS

Models

VK41.. series:

line voltage, two automatic shut off valves

for direct spark ignition (DBI) or hot surface

ignition (HSI) applications.

VK81.. series:

low voltage, two automatic shut off valves

for direct spark ignition (DBI) or hot surface

ignition (HSI) applications.

Suffix letter

R: fast opening, with integrated gas/air module

Pipe connection

Straight or elbow flanges.

Torsion and bending stress according to EN 126 group 2

Ambient temperature

0 ... 60

_

C for combined valve and ignition control

0 ... 70

_

C for stand alone valve

Dimensions

See fig. 1.

Pressure regulation function

Class B according to EN 88

Air pressure connections

M11 x 1

Subj

ect

to

change

wi

thout

not

ic

e.

Pr

in

te

d

in

the

Net

her

lands.

Summary of Contents for VK41 R Series

Page 1: ...in burner of domestic central heating equipment warm air furnaces back boilers and water heaters VK41 R VK81 R combined gas controls hold a first electric on off direct operator for opening the safety valve of class A or class B according to EN161 and a second electric on off servo operator of class B or class C to EN 161 VK41 R VK81 R combined gas controls comply with the additional requirement f...

Page 2: ...onal J Side outlet K Pressure tap gas pressure 2 9 mm outer diameter L Maximum pressure regulator optional M M5 x 0 8 pressure feedback connection N Outlet Ø 18 mm or 1 2 ISO 7 1 thread O Air pressure connection low M11 x 1 P Air pressure connection high M11 x 1 Q M8 x 1 pilot outlet for 4 mm tubing R Molex 1 1 square pin header S Flange thread 3 8 or 1 2 ISO 7 1 thread T Inlet Ø 18 mm or 1 2 ISO ...

Page 3: ...ustable amplification factor Amplification factor Minimum outlet pressure mbar Range Nominal pressure mbar 3 5 5 5 1 5 7 10 10 2 5 10 5 15 15 3 5 17 5 25 25 5 5 Outlet pressure Po Outlet pressure is pressure drop across the main burner orifice Air pressure difference Pair high Pair low Offset Offset Po Pair high x A Offset range 0 5 x A 0 0 x A mbar depending on O S number Outlet pressure range 0 ...

Page 4: ...pright position i e from the position when coil is on top When mounted in 90_ from the upright position a deviation of more than 3_ can result in an unacceptable deviation of gas pressure Al least one of the air connections must be made with a metal tube with an outside diameter of 6 mm To prevent blockage due to condensation the positive air pressure connection should not be connected to combusti...

Page 5: ...r to have gas input to burner and ignite boiler Adjust CO2 at the desired value at low output with offset adjustment screw Turn offset adjustment screw counter clockwise to increase CO2 Replace cap screw and tighten pressure taps Offset adjustment on outlet pressure Remove cap screw with a screw driver to expose offset adjustment screw Check gas supply pressure to the appliance using a pressure ga...

Page 6: ...9137 9808R6 NE 6 Home and Building Control Combustion Controls Center Europe Honeywell BV Phileas Foggstraat 7 7821 AJ Emmen The Netherlands Tel 31 591 695911 Fax 31 591 695200 http europe hbc honeywell com ...

Reviews: