VM242A BASICMES-2

Honeywell 

y

 Subject to change

3

EN0H-2323GE25 R0111

Accessories

Spare Parts

Pocket printer for VM242 Series

Pocket printer

VMA242A001

Spare paper rolls (pack of 
ten)

VMA242A002

Needle adapter with Rectus 21 socket

for all VM242, also suitable 
for VM241 and any other 
device with Rectus 21 plug

VMA242A003

Temperature sensor with clamp

for all VM242

VMA242A004

Handheld measuring computer

Device only, 
without accessories, carry 
case or batteries

VMS242A001

USB interface cable

VMS242A005

Battery charger

VMS242A006

Pressure hose

Pressure hose assembly for 
all VM242 
including bypass assembly, 
red and blue pressure hose, 
fittings and ballvalve

VMS242A002

Spare filters (set of two)

VMS242A003

SafeCon

TM

 plug (for blue 

hose)

VMS242A008

SafeCon

TM

 plug with ball-

valve (for red hose)

VMS242A009

Adapters

Rectus 21 socket onto 3/4” 
internal thread, with sealing

VMS242A004

SafeCon

TM

 socket onto 

Rectus 21 plug

VA2500B001

Carry case

Carry case with foam insert 
for VM242A

VMS242A007

P=0

Messen

Summary of Contents for VM242A BasicMes-2

Page 1: ... Direct Input of kv value 5 4 Function overview 5 4 1 How to access the Main Menu 5 4 2 Valve Selection Select valve 5 4 3 Project Function Select project 6 4 4 Flow Measurement Hydr balancing 6 4 5 Temperature Measurement 7 4 6 Leakage Test 7 4 7 Data Logging 7 4 8 DP Measurement 7 4 9 USB Data Exchange 8 4 10 Print 8 4 11 Save Measurements 8 4 12 Data management 8 4 13 Setup 8 4 14 Calibration 8...

Page 2: ...nd adjustment work may only be carried out by authorized persons Immediately rectify any malfunctions which may influence safety WARNING Attention has to be paid when hoses are removed from valve after measuring When quick connection is pulled off remaining hot media may leak presenting danger of scalding CAUTION Media gas water oil do not mix 2 BASIC INFORMATION 2 1 Intended Use The BasicMes 2 ha...

Page 3: ...cified ambient temperature see data sheet in appendix only Batteries will be exhausted if left for a long period of time after being charged Battery charger can be used as mains power supply for device e g during data logging if device is equipped with rechargeable batteries Device does not work when not equipped with batteries Also not when battery charger is connected WARNING Battery charger mus...

Page 4: ... 7 11 Menu bar The following descriptions assume the main screen as starting point 3 1 Flow Measurement using Valve Database Select valve and valve size from device database Compare valve presetting with presetting shown in display of the BasicMes 2 Values must be identical Connect the BasicMes 2 to valve red hose is installed to higher pressure outlet before orifice or valve seat blue hose is ins...

Page 5: ...BasicMes 2 shows the main screen as a default How to access the main menu and a menu item Operation Command Key Stop ongoing measurement Stop ON Change to main menu Menu ESC Operation Command Key Highlight menu item UP DOWN Select menu item Ok ON The main menu has the following menu items Table 4 Menu items of main menu Menu item Purpose Select valve Select valve from database Select project Selec...

Page 6: ...eady been stored for this riser which should not be overwritten Decline to overwrite existing data No ESC Operation Command Key The BasicMes 2 returns to riser selection where either another riser can be selected to store measurement or a new riser can be defined to store measurement or function can be left without storing measurement The measurement stays in the buffer memory of the BasicMes 2 un...

Page 7: ...ge test time with following options Operation Command Key Return to main menu without starting the test Esc ESC Select data field UP DOWN Change data ON The test consists of three parts Switch on and or set pump speed Stabilisation period indicated by a countdown clock Leakage test during which a graph is drawn Operation Command Key Confirm that pump has been switched on and set to correct speed P...

Page 8: ...t overwrite old data No ESC Device returns to riser selection screen Overwrite old data Yes ON Information screen appears Confirm notification Ok ON Device returns to main menu 4 12 Data management Used for following functions Menu item Purpose Print protocol Print measurements saved within a project over optional pocket printer Delete riser Delete single riser of a project Delete project Delete c...

Page 9: ...ign supply and return temperature 5 3 2 Riser Used for input of data concerning a riser distribution pipe or heat consumer Short description or name of riser free text field Design flow in l h or m h Selection of valve for this riser see below Remarks free text field 5 3 2 1 Selection of valve from valve database How to select a valve from the valve database Operation Command Open valve database S...

Page 10: ...options are available Deletion of one certain size Deletion of all sizes of a certain valve type Deletion of all valves of a certain manufacturer Deletion of all valves To delete a valve size valve type manufacturer or all valves from the database right click onto the respective point in the tree structure then click onto the delete option NOTE Deleted elements are immediately erased and cannot be...

Page 11: ...PERATING INSTRUCTIONS VM242A BASICMES 2 Honeywell All rights reserved 11 MU2H 1054GE25 R0411 7 ILLUSTRATIONS ABBILDUNGEN FIGURES FIGURA Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 1 2 3 Fig 8 Fig 9 Fig 10 ...

Page 12: ...VM242A BASICMES 2 OPERATING INSTRUCTIONS MU2H 1054GE25 R0411 12 Honeywell All rights reserved 8 MENU STRUCTURE ...

Page 13: ...OPERATING INSTRUCTIONS VM242A BASICMES 2 Honeywell All rights reserved 13 MU2H 1054GE25 R0411 9 HONEYWELL IN EMEA AND ASIA PACIFIC ...

Page 14: ...VM242A BASICMES 2 OPERATING INSTRUCTIONS MU2H 1054GE25 R0411 14 Honeywell All rights reserved 10 DATA SHEET ...

Page 15: ...s as well as some common valves of other manufacturers are stored in an internal database Manual input of the kv value is also possible Apart from differential pressure and flow measurement the BasicMes 2 has the following functions Two temperature sensor inputs for simultaneous using two sensors or successive using one sensor temperature measurements Data logging function with programmable interv...

Page 16: ...ate Normal 1Hz average value of four scans time slot four seconds Fast 4Hz no averaging Interface USB HP IR for communication with pocket printer Weight 2 5kg including accessories and carry case Dimensions 470 x 370 x 110mm length x width x height Pressure units mbar bar hPa kPa mH2O inH2O psi Temperature units C F Flow display up to 5mbar no display 0 1 000l h resolution 1l h 1 100m3 h resolutio...

Page 17: ...omputer Device only without accessories carry case or batteries VMS242A001 USB interface cable VMS242A005 Battery charger VMS242A006 Pressure hose Pressure hose assembly for all VM242 including bypass assembly red and blue pressure hose fittings and ballvalve VMS242A002 Spare filters set of two VMS242A003 SafeConTM plug for blue hose VMS242A008 SafeConTM plug with ball valve for red hose VMS242A00...

Page 18: ... Fax 49 6261 81393 www honeywell com EN0H 2323GE25 R0111 January 2011 2011 Honeywell International Inc Subject to change without notice Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl Z A La Pièce 16 1180 Rolle Switzerland or its Authorized Representative ...