6 - 43
timeout by scanning the bar code below, then setting the timeout (from 0-
65535 milliseconds) by scanning digits from the
, then
scanning
.
Default = 100.
Note: The Addenda Timeout setting is applied to all addenda and coupon
code searches.
UPC-E0 Addenda Separator
When this feature is
On
, there is a space between the data from the bar
code and the data from the addenda. When turned
Off
, there is no space.
Default = Off.
UPC-E0 Redundancy
If you are encountering errors when reading UPC-E0 bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of
times a bar code is decoded before transmission, which may reduce the
number of errors. Note that the higher the redundancy count, the longer it
will take to decode the bar code. To adjust the redundancy, scan the
UPC-
E0 Redundancy
bar code below, then scan a redundancy count between 0
and 10 on the
inside the back cover of this manual.
Then scan the
bar code.
Default = 1.
Addenda Timeout
* Off
On
UPC-E0 Redundancy