background image

11 - 2

Voyager 1450g2DHR Scanner Product Specifications

Parameter

Specification

Mechanical

Height

3.23 in. (82mm)

Length

2.45 in. (62mm)

Width

6.65 in. (169mm)

Weight

4.6 oz. (130g)

Electrical

Input Voltage

4.0 - 5.5VDC

Operating Power

2.25W (450mA @ 5VDC)

Standby Power

.45W  (90mA @ 5VDC)

Illumination LED

624nm peak wavelength red LED

Aiming

650nm peak wavelength laser

Optical Laser Power

<1mW

Environmental

Operating Temperature

32°F to 104°F (0°C to 40°C)

Storage Temperature

-40°F to 140°F (-40°C to 60°C)

Humidity

5 to 95% non-condensing

Drop

Operational after 30 drops to concrete from 5 ft. (1.5m)

Environmental Sealing

IP40

Light Levels

0 to 100,000 lux (9,290 foot-candles)

ESD

15kV Air, 8kV contact

Image

Image Size

1280 x 800 pixels

Scan Performance

Pitch, Skew

+60°, +70°

Motion Tolerance:
   Presentation Mode

up to 10cm per second for 13 mil UPC

Symbol Contrast

35%

Depth of Field

Typical Performance

5 mil Code 39

58 - 145mm (2.3 - 5.7 in.)

13 mil UPC-A

28 - 254mm (1.1 - 10 in.)

20 mil Code 39

30 - 325mm (1.2 - 12.8 in.)

6.7 mil PDF417

38 - 160mm (1.5 - 6.3 in.)

10mil Data Matrix

36 - 130mm (1.4 - 5.1 in.)

20mil QR Code

46 - 216mm (1.8 - 8.5 in.) 

Guaranteed Performance

5 mil Code 39

66 - 121mm (2.6 - 4.8 in.)

13 mil UPC-A

35 - 224mm (1.4 - 8.8 in.)

20 mil Code 39

33 - 249mm (1.3 - 9.8 in.)

6.7 mil PDF417

49 - 138mm (1.9 - 5.4 in.)

10mil Data Matrix

45 - 100mm (1.8 - 3.9 in.)

20mil QR Code

57 - 166mm (2.2 - 6.5 in.) 

Summary of Contents for Voyager 1450g Series

Page 1: ...Voyager 1450g 1452g 1450g2DHR Series Area Imaging Scanner User s Guide ...

Page 2: ...HII disclaims all responsibility for the selection and use of software and or hardware to achieve intended results This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of HII Copyright 2014 2015 Honeywell International Inc All...

Page 3: ...ion 2 1 Programming the Interface Plug and Play 2 1 Keyboard Wedge 2 1 Laptop Direct Connect 2 1 RS232 Serial Port 2 1 RS485 2 2 RS485 Packet Mode 2 2 USB IBM SurePos 2 3 USB PC or Macintosh Keyboard 2 3 USB HID 2 4 USB Serial 2 4 CTS RTS Emulation 2 4 ACK NAK Mode 2 4 Remote MasterMind for USB 2 5 Verifone Ruby Terminal Default Settings 2 5 Gilbarco Terminal Default Settings 2 5 Honeywell Bioptic...

Page 4: ...Between the Cordless System and the Host 3 2 Programming the Scanner and Base or Access Point 3 3 RF Radio Frequency Module Operation 3 3 System Conditions 3 3 Linking Process 3 3 Scanner Is Out of Range 3 3 Scanner Is Moved Back Into Range 3 3 Out of Range and Back into Range with Batch Mode On 3 3 Page Button 3 3 About the Battery 3 4 Charging Information 3 4 Battery Recommendations 3 4 Proper D...

Page 5: ...tion 3 18 Scanner Name 3 18 Application Work Groups 3 19 Application Work Group Selection 3 20 Resetting the Factory Defaults All Application Work Groups 3 20 Resetting the Custom Defaults All Application Work Groups 3 21 Pairing the Scanner with Bluetooth Devices 3 21 Virtual Keyboard 3 22 Bluetooth HID Keyboard Disconnect 3 23 Bluetooth Serial Port PCs Laptops 3 23 PDAs Mobility Systems Devices ...

Page 6: ...6 Presentation Sensitivity 4 6 Presentation Centering 4 6 In Stand Sensor Mode 4 8 Poor Quality Codes 4 8 Poor Quality 1D Codes 4 8 Poor Quality PDF Codes 4 9 CodeGate 4 9 Mobile Phone Read Mode 4 9 Hands Free Time Out 4 9 Reread Delay 4 10 User Specified Reread Delay 4 10 2D Reread Delay 4 10 Character Activation Mode 4 11 Activation Character 4 11 End Character Activation After Good Read 4 12 Ch...

Page 7: ...d a Data Format 6 1 Other Programming Selections 6 2 Terminal ID Table 6 3 Data Format Editor Commands 6 3 Move Commands 6 4 Search Commands 6 5 Miscellaneous Commands 6 7 Data Formatter 6 9 Primary Alternate Data Formats 6 9 Chapter 7 Symbologies All Symbologies 7 1 Message Length Description 7 1 Codabar 7 2 Codabar Concatenation 7 3 Code 39 7 4 Code 32 Pharmaceutical PARAF 7 5 Full ASCII 7 6 Cod...

Page 8: ...n 7 34 GS1 Emulation 7 34 TCIF Linked Code 39 TLC39 7 35 QR Code 7 35 QR Code Page 7 36 Data Matrix 7 37 Data Matrix Code Page 7 37 MaxiCode 7 38 Aztec Code 7 39 Aztec Code Page 7 39 Chinese Sensible Han Xin Code 7 40 Postal Codes 2D 7 41 Single 2D Postal Codes 7 41 Combination 2D Postal Codes 7 42 Postal Codes Linear 7 45 China Post Hong Kong 2 of 5 7 45 Korea Post 7 46 Chapter 8 Interface Keys K...

Page 9: ... Product Specifications 11 4 Standard Cable Pinouts 11 5 Serial Output 11 5 USB 11 5 RS485 Output 11 6 Chapter 12 Maintenance and Troubleshooting Repairs 12 1 Maintenance 12 1 Cleaning the Device 12 1 Inspecting Cords and Connectors 12 1 Replacing Cables in Corded Scanners 12 1 Replacing a Corded Scanner Interface Cable 12 2 Replacing Cables and Batteries in Cordless Systems 12 2 Replacing an Inte...

Page 10: ...viii Lower ASCII Reference Table A 4 ISO 2022 ISO 646 Character Replacements A 7 Unicode Key Maps A 9 Sample Symbols Programming Chart ...

Page 11: ...m directly by filling out our online support form Enter your contact details and the description of the question problem Telephone www honeywellaidc com locations For our latest contact information please check our website at the link above Product Service and Repair Honeywell International Inc provides service for all of its products through service centers throughout the world To obtain warranty...

Page 12: ...x ...

Page 13: ...e most common terminal and communications settings If you need to change these settings programming is accomplished by scanning the bar codes in this guide An asterisk next to an option indicates the default setting Unpacking Your Device After you open the shipping carton containing the product take the following steps Check for damage during shipment Report damage immediately to the carrier who d...

Page 14: ...l settings For additional USB programming and technical information refer to USB Application Note available at www honey wellaidc com Connecting with Keyboard Wedge Note This interface is not supported by the Voyager 1450g2DHR A scanner or cordless base can be connected between the keyboard and PC as a keyboard wedge where the scanner provides data output that is similar to keyboard entries The fo...

Page 15: ... The scanner beeps once The unit defaults to an IBM PC AT and compatibles keyboard wedge interface with a USA keyboard A carriage return CR suffix is added to bar code data Connecting with RS232 Serial Port Note This interface is not supported by the Voyager 1450g2DHR 1 Turn off power to the terminal computer 2 Connect the appropriate interface cable to the device Note For the scanner or cordless ...

Page 16: ...to secure the connector to the port 5 Once the scanner or cordless base has been fully connected power up the computer This interface programs 115 200 baud 8 data bits no parity and 1 stop bit Connecting with RS485 Note This interface is not supported by the Voyager 1450g2DHR A scanner or cordless base can be connected for an IBM POS terminal interface 1 Connect the appropriate interface cable to ...

Page 17: ...fy the scanner or cordless base operation by scanning a bar code from the Sample Symbols in the back of this manual The scanner beeps once For further RS485 settings refer to RS485 page 2 2 Corded Voyager 1450g RS232 Serial Port Connection CCB01 010BT Base RS485 Connection ...

Page 18: ...nts mil size should be read closer to the unit Symbologies with larger bars or elements mil size should be read farther from the unit To read single or multiple symbols on a page or on an object hold the scanner at an appropriate distance from the target press the trigger and center the aiming beam or pattern on the symbol If the code being scanned is highly reflective e g laminated it may be nece...

Page 19: ... Operation beginning on page 3 1 for additional information You may have a series of custom settings and want to correct a single setting To do so just scan the new setting to overwrite the old one For example if you had previously saved the setting for Beeper Volume at Low to your custom defaults and decide you want the beeper volume set to High just scan the Set Custom Defaults bar code then sca...

Page 20: ...1 8 ...

Page 21: ...ct Connect Note This interface is not supported by the Voyager 1450g2DHR For most laptops scanning the Laptop Direct Connect bar code allows operation of the scanner in parallel with the integral keyboard The following Laptop Direct Connect bar code also programs a carriage return CR suffix and turns on Emulate External Keyboard page 2 17 RS232 Serial Port Note This interface is not supported by t...

Page 22: ...M 4683 Port 9 HHBCR 2 Interface RS485 Packet Mode The following selection allows you to break up large bar code data into smaller packets on an IBM POS terminal To break up large bar codes into small packets scan the Packet Mode On bar code below Scan the Packet Mode Off bar code if you want large bar code data to be sent to the host in a single chunk Default Packet Mode Off Symbology Suffix Symbo...

Page 23: ... or IBM SurePos USB tabletop scanner interface Note After scanning one of these codes you must power cycle the cash register Each bar code above also programs the following suffixes for each symbology USB PC or Macintosh Keyboard Scan one of the following codes to program the scanner for USB PC Keyboard or USB Macintosh Keyboard Scanning these codes also adds a CR and LF Symbology Suffix Symbology...

Page 24: ...l website www honeywellaidc com The driver will use the next available COM Port number Apple Macintosh computers recognize the scanner as a USB CDC class device and automatically uses a class driver Note No extra configuration e g baud rate is necessary CTS RTS Emulation ACK NAK Mode USB Japanese Keyboard PC Note This interface is not supported by the Voyager 1450g2DHR USB HID Bar Code Scanner USB...

Page 25: ... Ruby terminal This bar code sets the baud rate to 1200 bps and the data format to 8 data bits mark parity bit 1 stop bit It also adds a line feed LF suffix and programs the fol lowing prefixes for each symbology Gilbarco Terminal Default Settings Note This interface is not supported by the Voyager 1450g2DHR Scan the following Plug and Play code to program the scanner for a Gilbarco terminal This ...

Page 26: ...ic Magellan bioptic scanner auxiliary port configura tion This bar code sets the baud rate to 9600 bps and the data format to 8 data bits no parity 1 stop bit NCR Bioptic Aux Port Configuration Note This interface is not supported by the Voyager 1450g2DHR Scan the following Plug and Play code to program the scanner for an NCR bioptic scanner auxiliary port configuration The fol lowing prefixes are...

Page 27: ...ager 1450g2DHR Scan the following Plug and Play code to program the scanner for a Wincor Nixdorf Beetle terminal This bar code sets the baud rate to 115200 bps and the data format to 8 data bits no parity 1 stop bit The following prefixes are programmed for each symbology Symbology Prefix Symbology Prefix Aztec Code V Interleaved 2 of 5 I Codabar N MaxiCode T Code 93 L MicroPDF417 S Code 128 K PDF...

Page 28: ...default is a US keyboard To change this layout refer to the chart below for your keyboard country Scan the appropriate bar code below to change the layout By default national character replacements are used for the following characters See ISO 2022 ISO 646 Character Replacements on page A 7 to view the character replacements for each country Symbology Prefix Symbology Prefix Code 128 K EAN 13 A Co...

Page 29: ...2 9 Keyboard Countries Continued Belgium Bosnia Brazil Brazil MS Bulgaria Cyrillic Bulgaria Latin Canada French legacy Canada French Canada Multilingual Croatia Czech ...

Page 30: ...2 10 Keyboard Countries Continued Czech Programmers Czech QWERTY Czech QWERTZ Denmark Dutch Netherlands Estonia Faroese Finland France Gaelic Germany ...

Page 31: ...2 11 Keyboard Countries Continued Greek Greek 220 Latin Greek 220 Greek 319 Latin Greek 319 Greek Latin Greek MS Greek Polytonic Hebrew Hungarian 101 key Hungary ...

Page 32: ...2 12 Keyboard Countries Continued Iceland Irish Italian 142 Italy Japan ASCII Kazakh Kyrgyz Cyrillic Latin America Latvia Latvia QWERTY Lithuania ...

Page 33: ...2 13 Keyboard Countries Continued Lithuania IBM Macedonia Malta Mongolian Cyrillic Norway Poland Polish 214 Polish Programmers Portugal Romania Russia ...

Page 34: ...2 14 Keyboard Countries Continued Russian MS Russian Typewriter SCS Serbia Cyrillic Serbia Latin Slovakia Slovakia QWERTY Slovakia QWERTZ Slovenia Spain Spanish variation ...

Page 35: ...2 15 Keyboard Countries Continued Sweden Switzerland French Switzerland German Tatar Turkey F Turkey Q Ukrainian United Kingdom United States Dvorak United States Dvorak left United Stated Dvorak right ...

Page 36: ... Lock is used if you change the Caps Lock key on and off The software tracks and reflects if you have Caps Lock on or off This selection can only be used with systems that have an LED that notes the Caps Lock status AT keyboards Autocaps via NumLock bar code should be scanned in countries e g Germany France where the Caps Lock key cannot be used to toggle Caps Lock The NumLock option works similar...

Page 37: ... menu code for Automatic Caps Lock page 2 16 Otherwise your output may not be as expected Default Keyboard Conversion Off Control Character Output This selection sends a text string instead of a control character For example when the control character for a carriage return is expected the output would display CR instead of the ASCII code of 0D Refer to ASCII Conversion Chart Code Page 1252 on page...

Page 38: ... Suffix Off The scanner sends key combinations for ASCII control characters for values 00 1F but it does not translate any prefix or suffix information Default Control ASCII Mode Off Turbo Mode The scanner sends characters to a terminal faster If the terminal drops characters do not use Turbo Mode Default Off Numeric Keypad Mode Sends numeric characters as if entered from a numeric keypad Default ...

Page 39: ...pping characters Default Off RS232 Modifiers RS232 Baud Rate Baud Rate sends the data from the scanner to the terminal at the specified rate The host terminal must be set for the same baud rate as the scanner Default 9600 Automatic Direct Connect Mode On Automatic Direct Connect Mode Off 300 600 1200 2400 4800 9600 19200 ...

Page 40: ...select 7 data bits For applications that require use of the full ASCII set select 8 data bits per character Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 Parity provides a means of checking character bit patterns for validity Default None 38400 57 600 115 200 7 Data 1 Stop Parity Even 7 Data 1 Stop Parity None 7 Data 1 Stop Parity Odd 7 Data 2 Stop Parity Even 7 Data 2 Stop Parity Non...

Page 41: ... scanner using software commands from the host device When RTS CTS is turned Off no data flow control is used Flow Control No Timeout The scanner asserts RTS when it has data to send and will wait indefinitely for CTS to be asserted by the host Two Direction Flow Control The scanner asserts RTS when it is OK for the host to transmit The host asserts CTS when it is OK for the device to transmit Flo...

Page 42: ... the scanner data transmission stops To resume transmission the host sends the XON character DC1 hex 11 Data transmission continues where it left off when XOFF was sent Default XON XOFF Off ACK NAK After transmitting data the scanner waits for an ACK character hex 06 or a NAK character hex 15 response from the host If ACK is received the communications cycle is completed and the scanner looks for ...

Page 43: ...tic scanner Default Packet Mode Off Scanner Bioptic ACK NAK Mode Bioptic ACK Nak On must be scanned so the scanner will wait for an ACK or NAK from a bioptic scanner after each packet is sent The Scanner Bioptic ACK NAK Timeout below controls how long the scanner will wait for a response Default Bioptic ACK NAK Off Scanner Bioptic ACK NAK Timeout This allows you to set the length in milliseconds f...

Page 44: ...2 24 ...

Page 45: ... then power up the computer once the base is fully connected When the base is con nected and powered up put the scanner in the base to establish a link The green LED on the base flashes to indicate the scan ner s battery is charging If the scanner and base have previously been linked you do not receive any feedback If this is the first time that the scanner and base are linked both devices emit a ...

Page 46: ... and the Host The cordless scanner provides immediate feedback in the form of a good read indication with a green LED on the scanner and an audible beep This indicates that the bar code has been scanned correctly and the base or Access Point has acknowledged receiving the data This is possible since the cordless system provides two way communication between the scanner and the base or Access Point...

Page 47: ...uto matically detects the scanner and links it to the base depending on the selected link mode Refer to Linking the Scanner to an Access Point page 3 1 for information about linking to an Access Point Scanner Is Out of Range The cordless scanner is in communication with its base or Access Point even when it is not transmitting bar code data Whenever the scanner can t communicate with the base or A...

Page 48: ... many times it will eventually be depleted Replace it after the battery is unable to hold an adequate charge If you are not sure if the battery or charger is working properly send it to Honeywell International Inc or an authorized service center for inspection Refer to see Customer Support on page ix for additional information Caution Use only Honeywell Li ion battery packs model number BAT SCN01 ...

Page 49: ...Power Communication Indicator To display the power indicator on a base or an Access Point scan the Base Power Communication Indicator On bar code To turn off the power indicator scan the Off bar code Default On LED Indication Beeper Indication Cause Normal Operation Red Flash None Battery low Green Flash 1 beep Successful communication or linking Red blinking Razz or error tone Failed communicatio...

Page 50: ...anner battery charges more slowly from a host interface cable than if auxiliary power were available Using the following selections you can specify whether the scanner battery is charged from power supplied via the host interface cable When Base Charge Off is selected the scanner battery does not charge when the scanner is in the base cradle When External or Interface Cable Power is selected the s...

Page 51: ...on the base or blue LED on the Access Point will remain lit to indicate that Paging Mode is off This light will go out when the button is pressed then back on when it s released Default Paging Mode On Paging Pitch When you press the Page button on the base or Access Point the scanners associated with that base or Access Point will begin beeping see Page Button on page 3 3 You can set the pitch of ...

Page 52: ...ample if you program this option to have five error beeps there will be five error beeps and five LED flashes in response to an error To change the number of error beeps scan the bar code below and then scan a digit 1 9 bar code and the Save bar code on the Programming Chart inside the back cover of this manual Default 1 Scanner Report Scan the bar code below to generate a report for the connected...

Page 53: ...ny subsequent scanners placed in that base will charge without linking to it The scanner used to program the base remains linked to the base To unlink this scanner scan Unlink Scanner on page 3 10 Note When in Charge Only Mode the scanner periodically wakes up and beeps See Power Up Beeper on page 4 1 to change this setting If you want to charge a scanner and link to the base use Charge and Link M...

Page 54: ...ked Unlinking the Scanner If a base or an Access Point has a scanner linked to it that scanner must be unlinked before a new scanner can be linked Once the previous scanner is unlinked it will no longer communicate with the base or Access Point To unlink the scanner from a base or an Access Point scan the Unlink Scanner bar code below Override Locked Scanner If you need to replace a broken or lost...

Page 55: ...he Save bar code on the Programming Chart inside the back cover of this manual Default 0 The sounds are as follows Scanner Power Time Out Timer Note Scanner Power Time out Timer only applies to cordless systems It does not apply to corded scanners When there is no activity within a specified time period the scanner enters low power mode Scan the appropriate scanner power time out bar code to chang...

Page 56: ...gger to power the unit back up There will be a set of power up beeps and a delay of up to a few seconds for the radio to join The scanner will then be ready to use Flexible Power Management If you are experiencing network performance issues and suspect the scanner is interfering with other devices you can turn down the power output of the scanner This reduces the range between the scanner and a ba...

Page 57: ... matically transmitted to the base or Access Point once the scanner is back in range When the scanner s buffer space is full any bar codes scanned generate an error tone In order to scan bar codes again the scanner must be moved back into range of the base or Access Point so data can be transmitted Inventory Batch Mode stores bar code data whether or not you are in range of the base or Access Poin...

Page 58: ...The scanner writes any untransmitted data to flash memory prior to powering down The data will still be there when the scanner powers back up However the scanner will power down even with untransmitted data if it reaches a power down timeout or if the battery power is very low RAM Storage The scanner will not power down while it contains data that has not been transmitted to the base or Access Poi...

Page 59: ...d the 2nd 3rd and 4th digits are moved to the left to accommodate the new digit For example if the Quantity 5 bar code is scanned after the quantity has been set to 1234 then the 1 is dropped the quan tity will be 2345 Example Add a quantity of 5 for the last item scanned 1 Scan the item s bar code 2 Scan the quantity 5 bar code Example Add a quantity of 1 500 for the last item scanned 1 Scan the ...

Page 60: ...ode Output Order When batch data is transmitted select whether you want that data sent as FIFO first in first out or LIFO last in first out Default Batch Mode FIFO 1 2 3 4 5 6 7 8 9 Batch Mode FIFO Batch Mode LIFO ...

Page 61: ...t scan the following bar code to transmit all the stored data to the host system Batch Mode Transmit Delay Sometimes when accumulated scans are sent to the host system the transmission of those scans is too fast for the appli cation to process To program a transmit delay between accumulated scans scan one of the following delays Default Off Note In most cases a short 250 ms milliseconds delay is i...

Page 62: ...XXXXXXXXX If you have more than one scanner linked to a base and they all have the same name the first scanner linked to the base receives commands When renaming a series of scanners with identical names unlink all except one of the scanners from the base Perform the rename operation using either the bar codes on page 3 19 or by sending the serial command Scanner Name BT_NAMNewName where ScannerNa...

Page 63: ...area versus the retail area You could assign all the scanners in the retail area to one work group and those in the warehouse to another Consequently any desired changes to either the retail or warehouse area would apply to all scanners in that particular work group Honeywell s online configuration tool EZConfig Scanning page 2 makes it easy for you to program your system for use with multiple sca...

Page 64: ...s beginning on page 10 3 The standard prod uct default settings for each of the commands are indicated by an asterisk Note Scanning this bar code also causes both the scanner and the base or Access Point to perform a reset and become unlinked The scanner must be placed in the base or the Access Point linking bar code must be scanned to re establish the link Refer to Scanner Modes page 3 9 for addi...

Page 65: ...h Devices The scanner can be paired with Bluetooth devices such as personal computers laptops and tablets 1 Scan the appropriate Bluetooth HID Keyboard Connect bar code below 2 Set your personal computer laptop or tablet so it searches for other Bluetooth devices Refer to your device s User s Guide for pairing instructions 3 Once your personal computer laptop or tablet has located the scanner sele...

Page 66: ...may begin scanning bar codes Verify the scanner opera tion by scanning a bar code from the Sample Symbols in the back of this manual Virtual Keyboard Once your scanner has been connected directly to an iPad smart phone or laptop you can toggle the virtual keyboard on your device with a quick double pull of the scanner trigger 2 3 4 5 6 7 8 9 Save ...

Page 67: ...DA or a Honeywell Mobility Systems device Scan the bar code below and follow the instructions supplied with your Bluetooth device to locate the scanner and connect with it Changing the Scanner s Bluetooth PIN Code Some devices require a PIN code as part of the Bluetooth security features Your scanner s default PIN is 1234 which you may need to enter the first time you connect to your PDA or PC The...

Page 68: ...int linking bar code or placing the scanner in the cradle resets the attempt count and the scanner will again try to link Event Auto Reconnect On Auto Reconnect Off Scanner out of range Relink occurs automatically If maximum number of link attempts is unsuccessful then the scanner must be relinked by either pulling the trigger placing the scanner in the base or scanning the Access Point linking ba...

Page 69: ...3 seconds of idle time After one hour the scanner powers off and batch mode data is lost Maximum Link Attempts set to 15 Other values at default setting When the scanner goes out of range 15 attempts are made to link to the base unit or Access Point Each attempt consists of approximately 5 seconds of active time followed by 3 seconds of idle time After 15 cycles 8 15 120 or about 2 min utes the sc...

Page 70: ... y is the application work group number ESC x is the escape command and the comma is the terminator which is required When y is not specified the command is sent to the default Application Work Group 0 Example Commands may be strung together to create custom response sequences An example of a command string is listed below 0 ESC 4 ESC 5 ESC 6 The above example will make a scanner that is in applic...

Page 71: ...followed by a pause ESC 2 The green LED illuminates for 2 seconds followed by a pause ESC 3 The green LED illuminates for 5 seconds followed by a pause ESC 4 Emits a beep at a low pitch ESC 5 Emits a beep at a medium pitch ESC 6 Emits a beep at a high pitch ESC 7 Beeps to indicate a successful decode and communication to host ESC 8 ESC 8 Razz or error tone to indicate a decode communication to hos...

Page 72: ...3 28 ...

Page 73: ... If you scan the Beep on BEL On bar code below the scanner will beep every time a BEL character is received from the host Default Beep on BEL Off Trigger Click To hear an audible click every time the scanner trigger is pressed scan the Trigger Click On bar code below Scan the Trigger Click Off code if you don t wish to hear the click This feature has no effect on serial or automatic triggering Def...

Page 74: ...ror and menu beeps are still audible Default Beeper Good Read On Beeper Volume Good Read The beeper volume codes modify the volume of the beep the scanner emits on a good read Default High Beeper Pitch Good Read The beeper pitch codes modify the pitch frequency of the beep the scanner emits on a good read Default Medium Trigger Click On Beeper Good Read Off Beeper Good Read On Low Medium High Off ...

Page 75: ... Duration Good Read The beeper duration codes modify the length of the beep the scanner emits on a good read Default Normal LED Good Read The LED indicator can be programmed On or Off in response to a good read Default On Medium 2400 Hz High 4200 Hz Razz 250 Hz Medium 3250 Hz High 4200 Hz Normal Beep Short Beep Short Beep LED Good Read On LED Good Read Off ...

Page 76: ...rogrammed from 1 9 For example if you program this option to have five error beeps there will be five error beeps and five LED flashes in response to an error To change the number of error beeps scan the bar code below and then scan a digit 1 9 bar code and the Save bar code on the Programming Chart inside the back cover of this manual Default 1 Good Read Delay This sets the minimum amount of time...

Page 77: ...ng the trigger or using a serial trigger command see Trigger Commands on page 10 3 When in serial mode the scanner scans until a bar code has been read or until the deactivate command is sent The scanner can also be set to turn itself off after a specified time has elapsed see Read Time Out which follows Read Time Out Use this selection to set a time out in milliseconds of the scanner s trigger wh...

Page 78: ...ugh ambient light the scanner may have difficulty detecting when a bar code is presented to it If the scanner has difficulty waking up to read bar codes you may need to set the Idle Illumination to a brighter setting Presentation Sensitivity Presentation Sensitivity is a numeric range that increases or decreases the scanner s reaction time to bar code presenta tion To set the sensitivity scan the ...

Page 79: ...he centering window it will be read Bar Code 2 does not pass through the centering window so it will not be read Note A bar code needs only to be touched by the centering window in order to be read It does not need to pass completely through the centering window Scan Presentation Centering On then scan one of the following bar codes to change the top bottom left or right of the centering window Th...

Page 80: ...improves the scanner s ability to read damaged or badly printed linear bar codes When Poor Quality 1D Reading On is scanned poor quality linear bar code reading is improved but the scanner s snappiness is decreased mak ing it less aggressive when reading good quality bar codes This setting does not affect 2D bar code reading Default Poor Quality 1D Reading Off Bottom of Presentation Centering Wind...

Page 81: ... Stand Mobile Phone Read Mode Note This feature is not supported by the VG1450g2DHR When this mode is selected your scanner is optimized to read bar codes from mobile phone or other LED displays However the speed of scanning printed bar codes may be slightly lower when this mode is enabled Note To turn off Mobile Phone Read Mode scan the Manual Trigger Mode bar code see page 4 5 Hands Free Time Ou...

Page 82: ...Presentation Mode see page 4 6 Default Medium User Specified Reread Delay If you want to set your own length for the reread delay scan the bar code below then set the delay from 0 30 000 milliseconds by scanning digits from the inside back cover then scanning Save 2D Reread Delay Sometimes 2D bar codes can take longer to read than other bar codes If you wish to set a separate Reread Delay for 2D b...

Page 83: ...vation then use Activation Character following to select the character you will send from the host to start scanning Default Off Activation Character This sets the character used to trigger scanning when using Character Activation Mode On the ASCII Conversion Chart Code Page 1252 page A 3 find the hex value that represents the character you want to use to trigger scanning Scan the following bar co...

Page 84: ...m the Programming Chart then scanning Save Default 5000 ms Character Deactivation Mode If you have sent a character from the host to trigger the scanner to begin scanning you can also send a deactivation character to stop scanning Scan the following On bar code to use character deactivation then use Deactivation Character following to select the character you will send from the host to terminate s...

Page 85: ...the trigger is pulled and when the picture is taken During the delay time the aiming light will appear but the LEDs won t turn on until the delay time is over Default Off User Specified Aimer Delay If you want to set your own length for the duration of the delay scan the bar code below then set the time out by scanning digits 0 4 000 ms from the Programming Chart inside the back cover of this manu...

Page 86: ...ght of Centering Window bar codes In the example below the white box is the centering window The centering window has been set to 20 left 30 right 8 top and 25 bottom Since Bar Code 1 passes through the centering window it will be read Bar Code 2 does not pass through the centering window so it will not be read Note A bar code needs only to be touched by the centering window in order to be read It...

Page 87: ...not be read If No Read is turned Off the NR will not appear Default Off If you want a different notation than NR for example Error or Bad Code you can edit the output message see Data Formatting beginning on page 6 1 The hex code for the No Read symbol is 9C Centering Off Top of Centering Window Bottom of Centering Window Left of Centering Window Right of Centering Window On Off ...

Page 88: ...r Video Reverse and Standard Bar Codes in order to read menu bar codes Note Images downloaded from the unit are not reversed This is a setting for decoding only Working Orientation Some bar codes are direction sensitive For example KIX codes and OCR can misread when scanned sideways or upside down Use the working orientation settings if your direction sensitive codes will not usually be presented ...

Page 89: ...4 17 Upright Vertical Bottom to Top Upside Down Vertical Top to Bottom ...

Page 90: ...4 18 ...

Page 91: ...ymbologies the specific symbology ID value counts as an added prefix or suffix character The maximum size of a prefix or suffix configuration is 200 characters which includes header information To Add a Prefix or Suffix Step 1 Scan the Add Prefix or Add Suffix symbol page 5 2 Step 2 Determine the 2 digit Hex value from the Symbology Chart included in the Symbology Charts beginning on page A 1 for ...

Page 92: ...c character from a symbology When you Clear All Prefixes Suffixes all the prefixes or suffixes for a symbology are deleted Step 1 Scan the Clear One Prefix or Clear One Suffix symbol Step 2 Determine the 2 digit Hex value from the Symbology Chart included in the Symbology Charts beginning on page A 1 for the symbology from which you want to clear the prefix or suffix Step 3 Scan the 2 digit hex va...

Page 93: ...he transmission of each character of scanned data Scan the Intercharacter Delay bar code below then scan the number of 5ms delays and the Save bar code using the Programming Chart inside the back cover of this manual To remove this delay scan the Intercharacter Delay bar code then set the number of delays to 0 Scan the Save bar code using the Programming Chart inside the back cover of this manual ...

Page 94: ...ual To remove this delay scan the Interfunction Delay bar code then set the number of delays to 0 Scan the Save bar code using the Programming Chart inside the back cover of this manual Intermessage Delay An intermessage delay of up to 5000 milliseconds in 5ms increments may be placed between each scan transmission Scan the Intermessage Delay bar code below then scan the number of 5ms delays and t...

Page 95: ... have changed data format settings and wish to clear all formats and return to the factory defaults scan the Default Data Format code below Add a Data Format Step 1 Scan the Enter Data Format symbol page 6 2 Step 2 Select Primary Alternate Format Determine if this will be your primary data format or one of 3 alternate formats This allows you to save a total of 4 different data formats To program y...

Page 96: ...at for one symbology If you are clearing the primary format scan 0 from the Programming Chart inside the back cover of this manual If you are clearing an alternate format scan 1 2 or 3 depending on the format you are clearing Scan the Terminal Type and Code I D see Symbology Charts on page A 1 and the bar code data length for the specific data format that you want to delete All other formats remai...

Page 97: ... Conversion Chart Code Page 1252 beginning on page A 3 for decimal hex and character codes F2 Example Send a number of characters Send the first 10 characters from the bar code above followed by a carriage return Command string F2100D F2 is the Send a number of characters command 10 is the number of characters to send 0D is the hex value for a CR The data is output as 1234567890 F2 and F1 Example ...

Page 98: ...rsor is moved forward to one position past the last input message character included Syntax E9nn where nn stands for the numeric value 00 99 for the number of characters that will not be sent at the end of the message Insert a character multiple times F4 Send xx character nn times in the output message leaving the cursor in the current position Syntax F4xxnn where xx stands for the insert characte...

Page 99: ...pulate bar codes that begin with a 1 Search for bar codes that begin with a 1 If a bar code matches move the cursor back to the beginning of the data and send 6 characters followed by a carriage return Using the bar code above Command string FE31F7F2060D FE is the Compare characters command 31 is the hex value for 1 F7 is the Move the cursor to the beginning command F2 is the Send a number of char...

Page 100: ... character Syntax E6xx where xx stands for the search character s hex value for its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 beginning on page A 3 for decimal hex and character codes E6 Example Remove zeroes at the beginning of bar code data This example shows a bar code that has been zero filled You may want to ignore the zeroes and send all the data that follows E6 searches ...

Page 101: ...ppress filter and clear all suppressed characters Syntax FC Replace characters E4 Replaces up to 15 characters in the output message without moving the cursor Replacement continues until the E5 command is encountered Syntax E4nnxx1xx2yy1yy2 zz1zz2 where nn is the total count of of the number of characters in the list characters to be replaced plus replacement characters xx1 defines characters to b...

Page 102: ...k for a number command F1 is the Send all characters command 0D is the hex value for a CR If this bar code is read the next data format if there is one will be used on the data If there is no other format the format fails and the raw data is output as AB1234 If this bar code is read the data is output as 1234AB CR Check for non numeric character ED Check to make sure there is a non numeric ASCII c...

Page 103: ...to your data format and prefixes and suffixes are transmitted Data Format Required Keep Prefix Suffix Scanned data is modified according to your data format and prefixes and suffixes are transmitted Any data that does not match your data format requirements generates an error tone and the data in that bar code is not transmitted Default Data Formatter On Not Required Keep Prefix Suffix Primary Alt...

Page 104: ...6 10 Data Format 3 ...

Page 105: ...of some of the bar code symbologies You may wish to set the same value for min imum and maximum length to force the scanner to read fixed length bar code data This helps reduce the chances of a misread All Symbologies Interleaved 2 of 5 Aztec Code Korea Post China Post Hong Kong 2 of 5 Matrix 2 of 5 Chinese Sensible Han Xin Code MaxiCode Codabar MicroPDF417 Codablock A MSI Codablock F NEC 2 of 5 C...

Page 106: ...All Codabar Settings Codabar On Off Codabar Start Stop Characters Start Stop characters identify the leading and trailing ends of the bar code You may either transmit or not transmit Start Stop characters Default Don t Transmit Codabar Check Character Codabar check characters are created using different modulos You can program the scanner to read only Codabar bar codes with Modulo 16 check charact...

Page 107: ...e two messages are concatenated into one with the D characters omitted Select Require to prevent the scanner from decoding a single D Codabar symbol without its companion This selection has no effect on Codabar symbols without Stop Start D characters Codabar Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information ...

Page 108: ...smits bar code data with or without a check character When Check Character is set to Validate but Don t Transmit the unit only reads Code 39 bar codes printed with a check character but will not transmit the check character with the scanned data When Check Character is set to Validate and Transmit the scanner only reads Code 39 bar codes printed with a check character and will transmit this charac...

Page 109: ...o the host computer When the scanner encounters a Code 39 bar code with the append trigger character s it buffers Code 39 bar codes until it reads a Code 39 bar code that does not have the append trigger The data is then transmitted in the order in which the bar codes were read FIFO Default Off Code 32 Pharmaceutical PARAF Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian p...

Page 110: ...If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements on page A 7 and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual The data characters should then appear properly NUL U DLE P SP SPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 ...

Page 111: ...eck digit with the scanned data When Check Digit is set to Validate and Transmit the scanner only reads Interleaved 2 of 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit Interleaved 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional informati...

Page 112: ...ansmit the unit only reads NEC 2 of 5 bar codes printed with a check digit but will not transmit the check digit with the scanned data When Check Digit is set to Validate and Transmit the scanner only reads NEC 2 of 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit Maximum Message Length On Off No Check Digit Validate but Don ...

Page 113: ...Default 4 Maximum Default 80 Code 93 Default All Code 93 Settings Code 93 On Off Code 93 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 0 80 Minimum Default 0 Maximum Default 80 Minimum Message Length Maximum Message Length On Off Minimum Message Length Maximum Message Length ...

Page 114: ...ode 93 bar code that starts with a character other than a space Default Off Code 93 Code Page Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code belo...

Page 115: ...of 5 Industrial On Off Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 On Off Minimum Message Length Maximum Message Length ...

Page 116: ...f 5 IATA On Off Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 On Off Minimum Message Length Maximum Message Length ...

Page 117: ...Matrix 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 On Off Minimum Message Length Maximum Message Length ...

Page 118: ...de 11 bar codes Default Two Check Digits Code 11 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 On Off One Check Digit Two Check Digits Minimum Message Length Maximum Message Length ...

Page 119: ...rent recommendation to use Code 128 due to its high degree of security and its space efficient design 3 a variation of Code 128 that supports concatenation of neigh boring symbols and 4 the standard layout for bar codes on a blood product label Use the bar codes below to turn concat enation on or off Default Off Code 128 Message Length Scan the bar codes below to change the message length Refer to...

Page 120: ...lt On Code 128 Code Page Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO ...

Page 121: ...th Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 1 80 Minimum Default 1 Maximum Default 80 UPC A Default All UPC A Settings UPC A On Off Note To convert UPC A bar codes to EAN 13 see Convert UPC A to EAN 13 on page 7 23 On Off Minimum Message Length Maximum Message Length On Off ...

Page 122: ... system digit of a U P C symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will not transmit it Default On UPC A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC A data Default Off for both 2 Digit and 5 Digit Addenda On Off On Off 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off ...

Page 123: ...le UPC A and EAN 13 with Extended Coupon Code When left on the default setting Off the scanner treats Coupon Codes and Extended Coupon Codes as single bar codes If you scan the Allow Concatenation code when the scanner sees the coupon code and the extended coupon code in a single scan it transmits both as one symbology Otherwise it transmits the first coupon code it reads If you scan the Require C...

Page 124: ... DataBar code data Default GS1 Out put Off UPC E0 Default All UPC E Settings UPC E0 On Off Most U P C bar codes lead with the 0 number system To read these codes use the UPC E0 On selection If you need to read codes that lead with the 1 number system use UPC E1 page 7 22 Default On UPC E0 Expand UPC E Expand expands the UPC E code to the 12 digit UPC A format Default Off GS1 Output Off GS1 Output ...

Page 125: ...om the bar code and the data from the addenda When turned Off there is no space Default On UPC E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not Default On UPC E0 Leading Zero This feature allows the transmission of a leading zero 0 at the beginning of scanned data To prevent transmission scan Off Default On Required Not Requir...

Page 126: ...git and 5 Digit Addenda UPC E1 Most U P C bar codes lead with the 0 number system For these codes use UPC E0 page 7 20 If you need to read codes that lead with the 1 number system use the UPC E1 On selection Default Off 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off UPC E1 On UPC E1 Off ...

Page 127: ...e converted to 13 digit EAN 13 codes by adding a zero to the front When Do not Convert UPC A is selected UPC A codes are read as UPC A EAN JAN 13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On On Off UPC A Converted to EAN 13 Do not Convert UPC A On Off ...

Page 128: ...hat have addenda Default Not Required EAN JAN 13 Addenda Separator When this feature is On there is a space between the data from the bar code and the data from the addenda When turned Off there is no space Default On Note If you want to enable or disable EAN13 with Extended Coupon Code refer to UPC A EAN 13 with Extended Coupon Code page 7 19 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda...

Page 129: ...o their equivalent ISBN number format Default Off EAN JAN 8 Default All EAN JAN 8 Settings EAN JAN 8 On Off EAN JAN 8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On On Off On Off On Off ...

Page 130: ...red is scanned the scanner will only read EAN JAN 8 bar codes that have addenda Default Not Required EAN JAN 8 Addenda Separator When this feature is On there is a space between the data from the bar code and the data from the addenda When turned Off there is no space Default On 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off Required Not Required On Off ...

Page 131: ...rinted with the specified type check character s and will transmit the character s at the end of the scanned data When Check Character is set to Validate Type 10 11 but Don t Transmit the unit will only read MSI bar codes printed with the specified type check character s but will not transmit the check character s with the scanned data On Off Validate Type 10 but Don t Transmit Validate Type 10 an...

Page 132: ...ngth Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 Validate Type 11 then Type 10 Character and Transmit Disable MSI Check Characters Minimum Message Length Maximum Message Length ...

Page 133: ... DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings GS1 DataBar Omnidirectional On Off GS1 DataBar Limited Default All GS1 DataBar Limited Settings GS1 DataBar Limited On Off On Off On Off ...

Page 134: ...Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 4 74 Minimum Default 4 Maximum Default 74 Codablock A Default All Codablock A Settings Codablock A On Off On Off Minimum Message Length Maximum Message Length On Off ...

Page 135: ... Maximum Default 600 Codablock F Default All Codablock F Settings Codablock F On Off Codablock F Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 1 2048 Minimum Default 1 Maximum Default 2048 Minimum Message Length Maximum Message Length On Off Minimum Message Length Maximum Mess...

Page 136: ...al information Minimum and Maximum lengths 1 2750 Minimum Default 1 Maximum Default 2750 MacroPDF417 MacroPDF417 is an implementation of PDF417 capable of encoding very large amounts of data into multiple PDF417 bar codes When this selection is enabled these multiple bar codes are assembled into a single data string Default On On Off Minimum Message Length Maximum Message Length On Off ...

Page 137: ... 7 1 for additional information Minimum and Maximum lengths 1 366 Minimum Default 1 Maximum Default 366 GS1 Composite Codes Linear codes are combined with a unique 2D composite component to form a new class called GS1 Composite symbology GS1 Composite symbologies allow for the co existence of symbologies already in use Default Off On Off Minimum Message Length Maximum Message Length On Off ...

Page 138: ...nclude UPC A and UPC E EAN 13 and EAN 8 ITF 14 GS1 128 and GS1 128 DataBar and GS1 Composites Any application that accepts GS1 data can be simplified since it only needs to recog nize one data carrier type If GS1 128 Emulation is scanned all retail codes U P C UPC E EAN8 EAN13 are expanded out to 16 digits If the AIM ID is enabled the value will be the GS1 128 AIM ID C1 see Symbology Charts on pag...

Page 139: ...he Code 39 linear component The MicroPDF417 component can only be decoded if TLC39 On is selected The linear component may be decoded as Code 39 even if TLC39 is off Default Off QR Code Default All QR Code Settings QR Code On Off This selection applies to both QR Code and Micro QR Code GS1 DataBar Emulation GS1 Code Expansion Off EAN8 to EAN13 Conversion GS1 Emulation Off On Off On Off ...

Page 140: ...e proper number of codes is reached the data is output in the order specified in the bar codes Default On QR Code Page QR Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the...

Page 141: ... bar code with the append trigger character s it buf fers the number of Data Matrix bar codes determined by information encoded in those bar codes Once the proper number of codes is reached the data is output in the order specified in the bar codes Default On Data Matrix Code Page Data Matrix Code pages define the mapping of character codes to characters If the data received does not display with ...

Page 142: ... data characters should then appear properly MaxiCode Default All MaxiCode Settings MaxiCode On Off MaxiCode Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 1 150 Minimum Default 1 Maximum Default 150 Data Matrix Code Page On Off Minimum Message Length Maximum Message Length ...

Page 143: ...ar code with the append trigger character s it buffers the number of Aztec bar codes determined by information encoded in those bar codes Once the proper number of codes is reached the data is output in the order specified in the bar codes Default On Aztec Code Page Aztec Code pages define the mapping of character codes to characters If the data received does not display with the proper characters...

Page 144: ...ters should then appear properly Chinese Sensible Han Xin Code Default All Han Xin Settings Han Xin Code On Off Han Xin Code Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 1 7833 Minimum Default 1 Maximum Default 7833 Aztec Code Page On Off Minimum Message Length Maximum Messag...

Page 145: ...an be active at a time If you scan a second 2D postal code selection the first selection is overwritten Default 2D Postal Codes Off Single 2D Postal Codes 2D Postal Codes Off Australian Post On British Post On Canadian Post On Intelligent Mail Bar Code On Japanese Post On KIX Post On Planet Code On Also see Planet Code Check Digit page 7 44 Postal 4i On ...

Page 146: ... and B Fields On InfoMail On InfoMail and British Post On Intelligent Mail Bar Code and Postnet with B and B Fields On Postnet and Postal 4i On Postnet and Intelligent Mail Bar Code On Postal 4i and Intelligent Mail Bar Code On Postal 4i and Postnet with B and B Fields On Planet Code and Postnet On ...

Page 147: ...On Planet Code Postnet and Intelligent Mail Bar Code On Planet Code Postal 4i and Intelligent Mail Bar Code On Postnet Postal 4i and Intelligent Mail Bar Code On Planet Code Postal 4i and Postnet with B and B Fields On Planet Code Intelligent Mail Bar Code and Postnet with B and B Fields On Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On ...

Page 148: ...ation is applied to customer fields in Australian 4 State symbols Bar Output lists the bar patterns in 0123 format Numeric N Table causes that field to be interpreted as numeric data using the N Table Alphanumeric C Table causes the field to be interpreted as alphanumeric data using the C Table Refer to the Australian Post Specification Tables Planet Code Postal 4i Intelligent Mail Bar Code and Po...

Page 149: ...ong Kong 2 of 5 Default All China Post Hong Kong 2 of 5 Settings China Post Hong Kong 2 of 5 On Off China Post Hong Kong 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for addi tional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Bar Output Numeric N Table Alphanumeric C Table Combination ...

Page 150: ...cription page 7 1 for addi tional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 Korea Post Check Digit This selection allows you to specify whether the check digit should be transmitted Default Don t Transmit Maximum Message Length On Off Minimum Message Length Maximum Message Length Transmit Check Digit Don t Transmit Check Digit ...

Page 151: ... following chart indicates the equiva lents of these five characters for different countries Function Code HEX ASCII Value Full ASCII CTRL X Mode NUL 00 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G BS 08 H HT 09 I LF 0A J VT 0B K FF 0C L CR 0D M SO 0E N SI 0F O DLE 10 P DC1 11 Q DC2 12 R DC3 13 S DC4 14 T NAK 15 U SYN 16 V ETB 17 W CAN 18 X EM 19 Y SUB 1A Z ESC 1B FS 1C GS 1D RS ...

Page 152: ...L make ACK 06 CTRL break CNTRL break BEL 07 CR Enter RETURN BS 08 Reserved APPLE make HT 09 Tab TAB LF 0A Reserved APPLE break VT 0B Tab TAB FF 0C Delete Del CR 0D CR Enter RETURN SO 0E Insert Ins Help SI 0F Escape ESC DLE 10 F11 F11 DC1 11 Home Home DC2 12 Print Prnt Scrn DC3 13 Back Space BACKSPACE DC4 14 Back Tab LSHIFT TAB NAK 15 F12 F12 SYN 16 F1 F1 ETB 17 F2 F2 CAN 18 F3 F3 EM 19 F4 F4 SUB 1...

Page 153: ...hen the unit is power cycled Show Decoder Revision Scan the bar code below to output the decoder revision Show Scan Driver Revision Scan the bar code below to output the scan driver revision The scan driver controls image capture Show Software Revision Scan the bar code below to output the current software revision unit serial number and other product information for both the scanner and the base ...

Page 154: ...s to the scanner and receive scanner response that can be seen in the Scan Data window The data dis played in the Scan Data window can either be saved in a file or printed Configure Configure displays the programming and configuration data of the scanner The scanner s programming and configu ration data is grouped into different categories Each category is displayed as a tree item under the Config...

Page 155: ...ult settings Note If using a cordless system scanning the Activate Defaults bar code also causes both the scanner and the base or Access Point to perform a reset and become unlinked The scanner must be placed in its base to re establish the link before any setup codes are entered If using an Access Point the linking bar code must be scanned See Cordless System Operation beginning on page 3 1 for a...

Page 156: ...9 4 ...

Page 157: ...es all work group settings and transfers to them to scanner once they are linked changes are typically done to the base and not to the scanner Tag A 3 character case insensitive field that identifies the desired menu command group For example all RS232 configuration settings are identified with a Tag of 232 SubTag A 3 character case insensitive field that identifies the desired menu command within...

Page 158: ...ndicates the command was good but the Data field entry was out of the allowable range for this Tag and SubTag combination e g an entry for a minimum message length of 100 when the field will only accept 2 characters When responding the device echoes back the command sequence with the status character inserted directly before each of the punctuation marks the period exclamation point comma or semic...

Page 159: ...ets the scanner to the custom default settings If there are no custom defaults it will reset the scanner to the factory default settings Any settings that have not been specified through the custom defaults will be defaulted to the factory default settings Note If using a cordless system scanning this bar code also causes both the scanner and the base or Access Point to perform a reset and become ...

Page 160: ...y Codes Verifone Ruby Terminal PAPRBY 2 5 Gilbarco Terminal PAPGLB 2 5 Honeywell Bioptic Aux Port PAPBIO 2 6 Datalogic Magellan Bioptic Aux Port PAPMAG 2 6 NCR Bioptic Aux Port PAPNCR 2 6 Wincor Nixdorf Terminal PAPWNX 2 7 Wincor Nixdorf Beetle PAPBTL 2 7 Wincor Nixdorf RS232 Mode A PAPWMA 2 8 Program Keyboard Country U S A KBDCTY0 2 8 Albania KBDCTY35 2 8 Azeri Cyrillic KBDCTY81 2 8 Azeri Latin K...

Page 161: ...Hungarian 101 key KBDCTY50 2 11 Hungary KBDCTY19 2 11 Iceland KBDCTY75 2 12 Irish KBDCTY73 2 12 Italian 142 KBDCTY56 2 12 Italy KBDCTY5 2 12 Japan ASCII KBDCTY28 2 12 Kazakh KBDCTY78 2 12 Kyrgyz Cyrillic KBDCTY79 2 12 Latin America KBDCTY14 2 12 Latvia KBDCTY42 2 12 Latvia QWERTY KBDCTY43 2 12 Lithuania KBDCTY44 2 12 Lithuania IBM KBDCTY45 2 13 Macedonia KBDCTY34 2 13 Malta KBDCTY74 2 13 Mongolian...

Page 162: ...es Dvorak KBDCTY87 2 15 United States International KBDCTY30 2 16 Uzbek Cyrillic KBDCTY77 2 16 Keyboard Conversion Keyboard Conversion Off KBDCNV0 2 17 Convert all Characters to Upper Case KBDCNV1 2 17 Convert all Characters to Lower Case KBDCNV1 2 17 Keyboard Style Regular KBDSTY0 2 16 Caps Lock KBDSTY1 2 16 Shift Lock KBDSTY2 2 16 Automatic Caps Lock KBDSTY6 2 16 Emulate External Keyboard KBDSTY...

Page 163: ...WRD1 2 20 7 Data 2 Stop Parity Odd 232WRD7 2 20 8 Data 1 Stop Parity Even 232WRD5 2 21 8 Data 1 Stop Parity None 232WRD2 2 21 8 Data 1 Stop Parity Odd 232WRD8 2 21 RS232 Receiver Time out Range 0 300 seconds 232LPT 2 21 RS232 Handshaking RTS CTS Off 232CTS0 2 22 Flow Control No Timeout 232CTS1 2 21 Two Direction Flow Control 232CTS2 2 21 Flow Control with Timeout 232CTS3 2 21 RS232 Timeout 232DEL ...

Page 164: ... High 4200 max 9000Hz BASFQ24200 3 8 Number of Beeps Base Error 1 BASERR3 3 8 Range 1 9 BASERR 3 8 Scanner Report Scanner Report RPTSCN 3 8 Scanner Address Scanner Address BT_LDA 3 9 Base Address Base Address BASLDA 3 9 Scanner Modes Charge Only Mode BASLNK0 3 9 Charge and Link Mode BASLNK1 3 9 Locked Link Mode BASCON0 DNG1 3 10 Open Link Mode BASCON1 DNG1 3 10 Unlink Scanner BT_RMV 3 10 Override ...

Page 165: ...9 BATNUM9 3 16 Batch Mode Output Order FIFO BATLIF0 3 16 LIFO BATLIF1 3 16 Total Records Total Records BATNRC 3 17 Delete Last Code Delete Last Code BATUND 3 17 Clear All Codes Clear All Codes BATCLR 3 17 Transmit Records to Host Transmit Inventory Records BAT_TX 3 17 Batch Mode Transmit Delay Off BATDLY0 3 17 Short ms BATDLY250 3 17 Medium ms BATDLY500 3 18 Long ms BATDLY1000 3 18 Multiple Scanne...

Page 166: ... Power Up Beeper Off Scanner BEPPWR0 4 1 Power Up Beeper On Scanner BEPPWR1 4 1 Beep on BEL Character Beep on BEL On BELBEP1 4 1 Beep on BEL Off BELBEP0 4 1 Trigger Click On BEPTRG1 4 2 Off BEPTRG0 4 1 Beep on BEL Character Beep on BEL On BELBEP1 4 1 Beep on BEL Off BELBEP0 4 1 Beeper Good Read Off BEPBEP0 4 2 On BEPBEP1 4 2 Beeper Volume Good Read Off BEPLVL0 4 2 Low BEPLVL1 4 2 Medium BEPLVL2 4 ...

Page 167: ...ring On PDCWIN1 4 7 Presentation Centering Off PDCWIN0 4 7 Left of Presentation Centering Window 40 PDCLFT 4 8 Right of Presentation Centering Window 60 PDCRGT 4 8 Top of Presentation Centering Window 40 PDCTOP 4 7 Bottom of Presentation Centering Window 60 PDCBOT 4 8 In Stand Sensor Mode Sensor On TRGSSW1 4 8 Sensor Off TRGSSW0 4 8 Poor Quality Codes Poor Quality 1D Reading On DECLDI1 4 8 Poor Qu...

Page 168: ... 13 400 milliseconds SCNDLY400 4 13 Off no delay SCNDLY0 4 13 User Specified Aimer Delay Range 0 4 000 ms SCNDLY 4 13 Aimer Mode Off SCNAIM0 4 13 Interlaced SCNAIM2 4 14 Centering Window Centering On DECWIN1 4 14 Centering Off DECWIN0 4 15 Left of Centering Window 40 DECLFT 4 15 Right of Centering Window 60 DECRGT 4 15 Top of Centering Window 40 DECTOP 4 15 Bottom of Centering Window 60 DECBOT 4 1...

Page 169: ...2 Clear All Data Formats DFMCA3 6 2 Data Formatter Data Formatter Off DFM_EN0 6 9 Data Formatter On Not Required Keep Prefix Suffix DFM_EN1 6 9 Data Format Required Keep Prefix Suffix DFM_EN2 6 9 Primary Alternate Data Formats Primary Data Format ALTFNM0 6 9 Data Format 1 ALTFNM1 6 9 Data Format 2 ALTFNM2 6 9 Data Format 3 ALTFNM3 6 10 Symbologies All Symbologies All Symbologies Off ALLENA0 7 1 Al...

Page 170: ...CII Off C39ASC0 7 6 On C39ASC1 7 6 Code 39 Code Page C39DCP 7 6 Interleaved 2 of 5 Default All Interleaved 2 of 5 Settings I25DFT 7 7 Off I25ENA0 7 7 On I25ENA1 7 7 Interleaved 2 of 5 Check Digit No Check Char I25CK20 7 7 Validate But Don t Transmit I25CK21 7 7 Validate and Transmit I25CK22 7 7 Interleaved 2 of 5 Message Length Minimum 2 80 4 I25MIN 7 7 Maximum 2 80 80 I25MAX 7 8 NEC 2 of 5 Defaul...

Page 171: ...raight 2 of 5 IATA Message Length Minimum 1 48 4 A25MIN 7 12 Maximum 1 48 48 A25MAX 7 12 Matrix 2 of 5 Default All Matrix 2 of 5 Settings X25DFT 7 13 Off X25ENA0 7 13 On X25ENA1 7 13 Matrix 2 of 5 Message Length Minimum 1 80 4 X25MIN 7 13 Maximum 1 80 80 X25MAX 7 13 Code 11 Default All Code 11 Settings C11DFT 7 14 Off C11ENA0 7 14 On C11ENA1 7 14 Code 11 Check Digits Required 1 Check Digit C11CK20...

Page 172: ...denda Required Not Required UPAARQ0 7 19 Required UPAARQ1 7 19 UPC A Addenda Separator Off UPAADS0 7 19 On UPAADS1 7 19 UPC A EAN 13 with Extended Coupon Code Off CPNENA0 7 19 Allow Concatenation CPNENA1 7 19 Require Concatenation CPNENA2 7 19 Coupon GS1 DataBar Output GS1 Output Off CPNGS10 7 20 GS1 Output On CPNGS11 7 20 UPC E0 Default All UPC E Settings UPEDFT 7 20 Off UPEEN00 7 20 On UPEEN01 7...

Page 173: ... Separator Off E13ADS0 7 24 On E13ADS1 7 24 ISBN Translate Off E13ISB0 7 25 On E13ISB1 7 25 EAN JAN 8 Default All EAN JAN 8 Settings EA8DFT 7 25 Off EA8ENA0 7 25 On EA8ENA1 7 25 EAN JAN 8 Check Digit Off EA8CKX0 7 25 On EA8CKX1 7 25 EAN JAN 8 Addenda 2 Digit Addenda Off EA8AD20 7 26 2 Digit Addenda On EA8AD21 7 26 5 Digit Addenda Off EA8AD50 7 26 5 Digit Addenda On EA8AD51 7 26 EAN JAN 8 Addenda R...

Page 174: ...SEDFT 7 30 Off RSEENA0 7 30 On RSEENA1 7 30 GS1 DataBar Expanded Msg Length Minimum 4 74 4 RSEMIN 7 30 Maximum 4 74 74 RSEMAX 7 30 Codablock A Default All Codablock A Settings CBADFT 7 30 Off CBAENA0 7 30 On CBAENA1 7 30 Codablock A Msg Length Minimum 1 600 1 CBAMIN 7 31 Maximum 1 600 600 CBAMAX 7 31 Codablock F Default All Codablock F Settings CBFDFT 7 31 Off CBFENA0 7 31 On CBFENA1 7 31 Codabloc...

Page 175: ... 1 7089 7089 QRCMAX 7 36 QR Code Append On QRCAPP1 7 36 Off QRCAPP0 7 36 QR Code Page QR Code Page 3 QRCDCP 7 36 Data Matrix Default All Data Matrix Settings IDMDFT 7 37 On IDMENA1 7 37 Off IDMENA0 7 37 Data Matrix Msg Length Minimum 1 3116 1 IDMMIN 7 37 Maximum 1 3116 3116 IDMMAX 7 37 Data Matrix Append On IDMAPP1 7 37 Off IDMAPP0 7 37 Data Matrix Code Page Data Matrix Code Page 51 IDMDCP 7 38 Ma...

Page 176: ...KPCCHK0 7 46 Postal Codes 2D 2D Postal Codes Off POSTAL0 7 46 Single 2D Postal Codes Australian Post On POSTAL1 7 41 British Post On POSTAL7 7 41 Canadian Post On POSTAL30 7 41 Intelligent Mail Bar Code On POSTAL10 7 41 Japanese Post On POSTAL3 7 41 KIX Post On POSTAL4 7 41 Planet Code On POSTAL5 7 41 Postal 4i On POSTAL9 7 41 Postnet On POSTAL6 7 42 Postnet with B and B Fields On POSTAL11 7 42 In...

Page 177: ... and Postnet On POSTAL28 7 44 Planet Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On POSTAL29 7 44 Planet Code Check Digit Transmit PLNCKX1 7 44 Don t Transmit PLNCKX0 7 44 Postnet Check Digit Transmit NETCKX1 7 44 Don t Transmit NETCKX0 7 44 Australian Post Interpretation Bar Output AUSINT0 7 45 Numeric N Table AUSINT1 7 45 Alphanumeric C Table AUSINT2 7 45 Combination N an...

Page 178: ...10 22 ...

Page 179: ...t 1 5m Environmental Sealing IP40 Light Levels 0 to 100 000 lux 9 290 foot candles ESD 15kV Air 8kV contact Image Image Size 640 x 480 pixels Scan Performance Pitch Skew 60 70 Motion Tolerance Presentation Mode up to 10cm per second for 13 mil UPC Symbol Contrast 35 Depth of Field Typical Performance 5 mil Code 39 45 107mm 1 8 4 2 in 13 mil UPC A 37 260mm 1 4 10 2 in 20 mil Code 39 42 360mm 1 6 14...

Page 180: ...te from 5 ft 1 5m Environmental Sealing IP40 Light Levels 0 to 100 000 lux 9 290 foot candles ESD 15kV Air 8kV contact Image Image Size 1280 x 800 pixels Scan Performance Pitch Skew 60 70 Motion Tolerance Presentation Mode up to 10cm per second for 13 mil UPC Symbol Contrast 35 Depth of Field Typical Performance 5 mil Code 39 58 145mm 2 3 5 7 in 13 mil UPC A 28 254mm 1 1 10 in 20 mil Code 39 30 32...

Page 181: ...rature with battery 4 F to 95 F 20 C to 35 C storage for 90 days 4 F to 68 F 20 C to 20 C storage for 1 year Humidity Up to 95 non condensing Drop Operational after 30 drops to concrete from 5 ft 1 5 m Environmental Sealing IP42 Vibration Withstands 5G peak from 5 to 300 Hz ESD 12kV Air 8kV contact Image Image Size 640 x 480 pixels Scan Performance Pitch Skew 60 70 Motion Tolerance Presentation Mo...

Page 182: ...Voltage 4 5 to 5 5 volts Current Draw Host Terminal Port 500mA Aux Power Port 1A Charge Time 5 hours Radio Frequency 2 4 to 2 5 GHz ISM Band Frequency Hopping Bluetooth v 2 1 Range 33 ft 10 m typical Data Rate Up to 1 MBps Temperature Ranges Operating 32 F to 122 F 0 C to 50 C Battery Charge 41 F to 104 F 5 C to 40 C Storage 40 F to 158 F 40 C to 70 C Humidity Up to 95 non condensing Mechanical Dr...

Page 183: ...t covered by your warranty Keyboard Wedge 10 Pin RJ41 Modular Plug Serial Output 10 Pin RJ41 Modular Plug USB 10 Pin Modular Plug 1 Cable shield 2 Cable select 3 Supply ground 4 Terminal data 5 Terminal clock 6 Keyboard clock 7 5V power 8 Keyboard data 9 10 1 Cable shield 2 Cable select 3 Supply ground 4 Transmit data 5 Receive data serial data to scanner 6 CTS 7 5V power 8 RTS 9 10 1 Cable shield...

Page 184: ...t 10 Pin RJ41 Modular Plug Note RS485 signal conversion is performed in the cable 1 Cable shield 2 Cable select 3 Supply ground 4 Transmit data 5 Receive data serial data to scanner 6 7 5V power 8 Transmit Enable 9 10 ...

Page 185: ...11 7 Required Safety Labels Part Number Serial Number Laser Label and Revision Information location Laser Safety information Laser Output Voyager 1450g 1452g Scanner ...

Page 186: ...11 8 CCB01 010BT Base Part Number Serial Number and Revision Information location Compliance Label locations ...

Page 187: ...ing Cords and Connectors Inspect the interface cable and connector for wear or other signs of damage A badly worn cable or damaged connector may interfere with scanner operation Contact your distributor for information about cable replacement Cable replacement instructions are on page 12 1 Replacing Cables in Corded Scanners The standard interface cable is attached to the scanner with an 10 pin mo...

Page 188: ... then remove the paper clip 6 Replace with the new cable Insert the connector into the opening and press firmly The connector is keyed to go in only one way and will click into place Replacing Cables and Batteries in Cordless Systems Replacing an Interface Cable in a Base 1 Turn the power to the host system OFF 2 Disconnect the base s cable from the terminal or computer 3 Turn the base upside down...

Page 189: ...he Tab key for example You need to program a suffix Programming a suffix enables the scanner to output the bar code data plus the key you need such as CR to enter the data into your application Refer to Prefix Suffix Overview beginning on page 5 1 for further information The scanner won t read your bar code at all Scan the sample bar codes in the back of this manual If the scanner reads the sample...

Page 190: ...ough scratched or exhibiting voids Aren t coated with frost or water droplets on the surface Are enabled in the base or Access Point to which the scanner connects Is the bar code displayed but not entered into the application The bar code is displayed on the host device correctly but you still have to press a key to enter it the Enter Return key or the Tab key for example You need to program a suf...

Page 191: ...abar Fm 0 1 a 61 Code 11 H3 h 68 Code 128 Cm 0 1 2 4 j 6A Code 32 Pharmaceutical PARAF X0 3C Code 39 supports Full ASCII mode Am 0 1 3 4 5 7 b 62 TCIF Linked Code 39 TLC39 L2 T 54 Code 93 and 93i Gm 0 9 A Z a m i 69 EAN Em 0 1 3 4 d 64 EAN 13 including Bookland EAN E0 d 64 EAN 13 with Add On E3 d 64 EAN 13 with Extended Coupon Code E3 d 64 EAN 8 E4 D 44 EAN 8 with Add On E3 D 44 GS1 GS1 DataBar em...

Page 192: ...Code zm 0 9 A C z 7A Chinese Sensible Code Han Xin Code X0 H 48 Codablock A O6 0 1 4 5 6 V 56 Codablock F Om 0 1 4 5 6 q 71 Code 49 Tm 0 1 2 4 l 6C Data Matrix dm 0 6 w 77 GS1 em 0 3 y 79 GS1 Composite em 0 3 y 79 GS1 DataBar Omnidirectional em 0 3 y 79 MaxiCode Um 0 3 x 78 PDF417 Lm 0 2 r 72 MicroPDF417 Lm 0 5 R 52 QR Code Qm 0 6 s 73 Micro QR Code Qm s 73 AIM Honeywell Symbology ID Possible modi...

Page 193: ...CII CTRL X Mode Control X Mode Off KBDCAS0 Windows Mode Control X Mode On KBDCAS2 DEC HEX Char CTRL X CTRL X function 0 00 NUL Reserved CTRL 1 01 SOH NP Enter CTRL A Select all 2 02 STX Caps Lock CTRL B Bold 3 03 ETX ALT Make CTRL C Copy 4 04 EOT ALT Break CTRL D Bookmark 5 05 ENQ CTRL Make CTRL E Center 6 06 ACK CTRL Break CTRL F Find 7 07 BEL Enter Ret CTRL G 8 08 BS Apple Make CTRL H History 9 ...

Page 194: ...8 72 48 H 104 68 h 41 29 73 49 I 105 69 i 42 2A 74 4A J 106 6A j 43 2B 75 4B K 107 6B k 44 2C 76 4C L 108 6C l 45 2D 77 4D M 109 6D m 46 2E 78 4E N 110 6E n 47 2F 79 4F O 111 6F o 48 30 0 80 50 P 112 70 p 49 31 1 81 51 Q 113 71 q 50 32 2 82 52 R 114 72 r 51 33 3 83 53 S 115 73 s 52 34 4 84 54 T 116 74 t 53 35 5 85 55 U 117 75 u 54 36 6 86 56 V 118 76 v 55 37 7 87 57 W 119 77 w 56 38 8 88 58 X 120 ...

Page 195: ...C 146 92 Æ F3 0x3D 147 93 ô F4 0x3E 148 94 ö F5 0x3F 149 95 ò F6 0x40 150 96 û F7 0x41 151 97 ù F8 0x42 152 98 ÿ F9 0x43 153 99 Ö F10 0x44 154 9A š Ü F11 0x57 155 9B F12 0x58 156 9C œ Numeric Keypad 0x4E 157 9D Numeric Keypad 0x4A 158 9E ž Numeric Keypad 0x37 159 9F Ÿ ƒ Caps Lock 0x3A 160 A0 á Num Lock 0x45 161 A1 í Left Alt 0x38 162 A2 ó Left Ctrl 0x1D 163 A3 ú Left Shift 0x2A 164 A4 ñ Right Shif...

Page 196: ... C8 È 201 C9 É 202 CA Ê 203 CB Ë 204 CC Ì 205 CD Í 206 CE Î 207 CF Ï 208 D0 Ð 209 D1 Ñ 210 D2 Ò 211 D3 Ó 212 D4 Ô 213 D5 Õ 214 D6 Ö 215 D7 216 D8 Ø 217 D9 Ù 218 DA Ú 219 DB Û 220 DC Ü 221 DD Ý 222 DE Þ 223 DF ß 224 E0 à α 225 E1 á ß 226 E2 â Γ 227 E3 ã π 228 E4 ä Σ 229 E5 å σ 230 E6 æ µ Extended ASCII Characters Continued DEC HEX CP 1252 ASCII Alternate Extended PS2 Scan Code ...

Page 197: ...44 F4 ô 245 F5 õ 246 F6 ö 247 F7 248 F8 ø 249 F9 ù 250 FA ú 251 FB û 252 FC ü ⁿ 253 FD ý 254 FE þ 255 FF ÿ Code Page Selection Method Country Standard Keyboard Country Honeywell Code Page Option United States standard ASCII ISO IEC 646 IRV n a 1 Automatic National Character Replacement ISO IEC 2022 n a 2 default Binary Code page n a n a 3 Default Automatic National Character replacement will selec...

Page 198: ... Hex 23 24 40 5B 5C 5D 5E 60 7B 7C 7D 7E US 0 1 CA 54 95 à â ç ê î ô é ù è û CA 18 96 à â ç ê É ô é ù è û JP 28 98 CN 92 99 GB 7 87 FR 3 83 à ç µ é ù è DE 4 84 Ä Ö Ü ä ö ü ß CH 6 86 ù à é ç ê î ô ä ö ü û SE FI 2 82 É Ä Ö Å Ü é ä ö å ü DK 8 88 Æ Ø Å æ ø å NO 9 94 Æ Ø Å æ ø å IE 73 97 Ó É Í Ú Á ó é í ú á IT 5 85 ç é ù à ò è ì PT 13 92 Ã Ç Õ ã ç õ ES 10 90 Ñ ñ ç ES 51 91 Ñ Ç ñ ç COUNTRY Country Keybo...

Page 199: ...54 59 3A 3B 3C 3E 3F 38 40 3D 5A 5F 64 5B 60 65 5C 61 66 5D 62 67 63 68 69 6A 6C 104 Key U S Style Keyboard 6E 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 4B 50 55 4C 51 56 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1E 2C 1F 20 21 22 23 24 25 26 27 28 29 2B 39 2E 2F 30 31 32 33 34 35 36 37 53 4F 54 59 3A 3B 3C 3E 3F 38 40 3D 5A 5F 64 5B 60 65 5C 61 66 5D 62 6...

Page 200: ...A 10 ...

Page 201: ...Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 1234567890 EAN 13 9 780330 290951 Code 128 Code 128 Code 39 BC321 Codabar A13579B Code 93 123456 9 Straight 2 of 5 Industrial 123456 ...

Page 202: ...6543210 Matrix 2 of 5 GS1 DataBar 01 00123456789012 PDF417 Car Registration Data Matrix Test Symbol QR Code Numbers Aztec Package Label MaxiCode Test Message Micro PDF417 Test Message Postnet Zip Code ...

Page 203: ...4 CB 4 State Customer Bar Code 01 234 567094 987654321 01234567891 ID tag UPU 4 State J18CUSA8E6N062315014880T ...

Page 204: ...Programming Chart 0 1 2 3 4 5 6 7 8 9 ...

Page 205: ...Programming Chart Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save again A B C D E F Save Discard Reset ...

Page 206: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com VG1450 UG Rev B 7 15 ...

Reviews: