2 - 22
Scanner to Bioptic Communication
The following Scanner to Bioptic Communication settings should only be used when connecting through an Access Point.
They are used to set up communication between Honeywell scanners and bioptic scanners.
Note: The scanner’s baud rate must be set to 38400 and the RS232 timeout must be set to 3000 in order to communicate
with a bioptic scanner. See "RS232 Modifiers" on page 2-18, and
on page 2-21 for further
information.
Scanner-Bioptic Packet Mode
Packet Mode On
must be scanned to set the scanner’s format so it is compatible with a bioptic scanner.
Default =
Packet Mode Off.
Scanner-Bioptic ACK/NAK Mode
Bioptic ACK/NAK On
must be scanned so the scanner will wait for an ACK or NAK from a bioptic scanner after each
packet is sent. The Scanner-Bioptic ACK/NAK Timeout (below) controls how long the scanner will wait for a response.
Default =
Bioptic ACK/NAK Off.
Scanner-Bioptic ACK/NAK Timeout
This allows you to set the length (in milliseconds) for a timeout for a bioptic scanner’s ACK/NAK response. Scan the
bar code below, then set the timeout (from 1-30,000 milliseconds) by scanning digits from the inside back cover, then
scanning
Save
.
Default = 5100.
* Packet Mode Off
Packet Mode On
* Bioptic ACK/NAK Off
Bioptic ACK/NAK On
ACK/NAK Timeout
Summary of Contents for Voyager 1602g
Page 1: ...Voyager 1602g Wireless Area Imaging Pocket Scanner User s Guide ...
Page 10: ...viii ...
Page 12: ...x ...
Page 84: ...4 20 Upright Vertical Bottom to Top Upside Down Vertical Top to Bottom ...
Page 100: ...6 12 ...
Page 150: ...7 50 ...
Page 180: ...10 24 ...
Page 184: ...11 4 ...
Page 188: ...12 4 ...