VR9105V, F AND VR9205V, F DIRECT IGNITION GAS CONTROL WITH INTEGRATED 1:1 REGULATOR
69-2471EF—01
2
Fig. 1. VR9105V, F and VR9205V, F End Outlet.
Fig. 2. VR9105V, F and VR9205V, F Side Outlet.
PLANNING THE
INSTALLATION
WARNING
Fire or Explosion Hazard.
Can cause property damage, severe injury,
or death.
Follow these warnings exactly:
1. Plan the installation as outlined below.
2. Plan for frequent maintenance as described in
the Maintenance section.
Heavy demands are made on the controls when direct
ignition systems are used on central heating equipment in
barns, greenhouses, and commercial properties and on
heating appliances such as commercial cookers,
agricultural equipment, industrial heating equipment and
pool heaters.
Special steps may be required to prevent nuisance
shutdowns and control failure due to frequent cycling,
severe environmental conditions related to moisture,
corrosive chemicals, dust or excessive heat. These
applications require Honeywell Combustion Engineering
review; contact your Honeywell Sales Representative for
assistance.
Review the following conditions that can apply to your
specific installation and follow the precautions suggested.
M32193
2-11/16 (65)
1-1/16
(27)
1/8
(3)
1-3/16
(30)
1-3/16
(30)
1:1 REGULATOR
OUTLET
PRESSURE
TAP 1/6-27
NPT
REFERENCE
PRESSURE
CONNECTION
OUTLET
1/2-14
NPT
3-3/16
(80)
5 (127)
INLET
1/2-14
NPT
3/8 (9)
INLET PRESSURE
TAP 1/6-27 NPT
3-7/16
(87)
7/8 (22)
M32194
OUTLET
PRESSURE
TAP 1/6-27
NPT
REFERENCE
PRESSURE
CONNECTION
1-3/16
(30)
2-11/16 (65)
1-1/16
(27)
1-3/16
(30)
1/8
(3)
3-3/16
(80)
OUTLET 1/2-14 NPT
5 (127)
3-3/16 (80)
INLET
1/2-14
NPT
3-7/16
(87)
3/8 (9)
INLET
PRESSURE
TAP 1/6-27 NPT
7/8 (22)
1:1 REGULATOR