Summary of Contents for VS820A

Page 1: ...D Hi Low V5308A VS820P Step V5307B 40 to 175 40 to 79 VS820V Standard V5306A WARNING FIRE OR EXPLOSION HAZARD CAN CAUSE PROPERTY DAMAGE SEVERE IN JURY OR DEATH Follow these warnings exactly 1 Disconnect power supply before wiring to pre vent electrical shock or equipment damage 2 To avoid dangerous accumulation of fuel gas turn off gas supply at appliance service valve before starting installation...

Page 2: ...able or 50 ft 15 3 m of 2 wire 16 gauge cable INLET AND OUTLET ADAPTERS If adapters are needed prepare control as follows 1 Remove seal over control inlet or outlet 2 Apply moderate amount of good quality pipe com pound to adapter leaving two end threads bare Refer to Fig 1 On LP installation use compound resistant to LP gas Do NOT use Teflon tape 3 Insert adapter in control and thread carefully u...

Page 3: ... Figs 3 and 4 If tubing is used connect tubing to coupling CONNECT PILOT GAS TUBING 1 Cut tubing to desired length and bend as necessary for routing to pilot burner Do not make sharp bends or deform tubing Do not bend tubing at control after compres sion nut has been tightened as this may result in gas leakage at the connection 2 Square off and remove burrs from end of tubing 3 Unscrew brass compr...

Page 4: ...out turn gas control knob clockwise to OFF Repeat steps 1 3 4 Release gas control knob If pilot remains lit turn counterclockwise to ON ADJUST PILOT FLAME Thepilotflameshouldenvelop3 8to1 2in 10to13mm of the tip of the generator Refer to Fig 9 Fig 9 Proper flame adjustment TURN ON MAIN BURNER Follow instructions provided by appliance manufacturer or turn up thermostat to call for heat CHECK AND AD...

Page 5: ...eld adjustable The HI or LOW flame setting is selected by position ing the white knob on the regulator Refer to Fig 10 Fig 10 HI and LOW settings for VS820D 1 Check the LOW flame setting listed on the appliance nameplate Gas control LOW flame setting should match this rating 2 With main burner operating check gas control outlet flowrateusingthemeterclockingmethodoroutletpressure using a manometer ...

Page 6: ...ge 4 b Compression fitting has a gas leak replace old compression fitting or tighten new one Refer to page 3 c Pilot burner tubing or orifice is clogged replace combination gas control Refer to page 1 IF PILOT GOES OUT WHEN GAS CONTROL KNOB IS RELEASED 1 Make sure the gas control knob is held in at least one minute to allow the generator time to heat 2 Check pilot flame adjustment refer to page 4 ...

Page 7: ...ontrol knob all the way and hold in Immedi ately light the pilot with a match Continue to hold the control knob in for about one 1 minute after the pilot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 5 10 10 Replace pilot access panel 11 Turn gas control knob counterclockwise to ON 12 Replace control access panel 13 Turn on all electric power to th...