background image

Wireless Alarm Bar Installation Guide 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

© 2018 Honeywell International. 

Product Registration 

Register your product online by visiting: 

http://www.raesystems.com/support/product-registration 

By registering your product, you can: 

 

Receive notification of product upgrades or enhancements  

 

Be alerted to Training classes in your area  

 

Take advantage of RAE Systems special offers and promotions 

 

Summary of Contents for Wireless Alarm Bar

Page 1: ...Wireless Alarm Bar Installation Guide 1 Wireless Alarm Bar TM Rev B August 2018 P N F08 4007 000 Installation Guide ...

Page 2: ... Register your product online by visiting http www raesystems com support product registration By registering your product you can Receive notification of product upgrades or enhancements Be alerted to Training classes in your area Take advantage of RAE Systems special offers and promotions ...

Page 3: ...less Alarm Bar 8 3 1 2 Optional Pole Mounting 9 3 2 Wireless Alarm Bar Wiring 10 3 2 1 Complete Wireless Alarm Bar Wiring Diagram 10 3 2 2 Opening The Junction Box 12 3 2 3 Connecting AC Power Mains Wiring 13 3 2 4 Reassembly 14 3 2 5 External Grounding 14 4 Powering And Programming 15 5 AC Powered Wireless Alarm Bar Specifications 15 6 DC Powered Wireless Alarm Bar Specifications 16 ...

Page 4: ... uniquement par un personnel qualifié Étudier le manuel d instructions en entier avant d utiliser d entretenir ou de réparer l équipement Read Before Operating This manual must be carefully read by all individuals who have or will have the responsibility of using maintaining or servicing this product The product will perform as designed only if it is used maintained and serviced in accordance with...

Page 5: ...ations However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the sep...

Page 6: ...s C D hazardous locations USA only Key Features Mounted and pre wired with two 10J xenon lights and a 112dB horn Five internal SPDT relays Wireless transmission distance of 1000 ft 300m line of sight Range can be extended by using wireless routers Suitable for use in Class I Division 2 Groups C D hazardous locations USA only LEDs indicate status Applications Oil and gas exploration Refineries and ...

Page 7: ... Bar can be configured for large or small systems and the network can be expanded or units removed depending on the facility or facilities being monitored Simple configuration that uses MeshGuard sensors and a Wireless Alarm Bar host Full network including externally controlled devices ...

Page 8: ... on a wall use heavy duty steel screws located as indicated below Follow these steps 1 Locate the Wireless Alarm Bar on a wall or other flat surface Make sure there is at least 12 30 cm of clearance around the unit Mark the mounting holes locations 2 Remove the Wireless Alarm Bar 3 Drill pilot holes in the wall or mounting surface 4 Hold the Wireless Alarm Bar firmly against the wall or mounting s...

Page 9: ...he two holes that are side by side in order to mount the Wireless Alarm Bar s plate to a vertical pole Loosely assemble the clamp parts around the pole Note that the screws have nuts that fit into the clamp parts The clamp parts are designed to hold the nut so that you do not need to use a wrench on this side Hand tighten the parts until snug Use a hex wrench to tighten the hex screws from the fro...

Page 10: ...it IMPORTANT Prior to factory shipment the RAEPoint is tested However the instrument should be tested after installation 3 2 1 Complete Wireless Alarm Bar Wiring Diagram The schematic diagram below shows internal wiring of the Wireless Alarm Bar Refer to the diagram on page 13 for power connections Note Thermistors are pre installed in the Junction Box to protect the relays Wires must be fed in th...

Page 11: ...Wireless Alarm Bar Installation Guide 11 ...

Page 12: ...order to connect wires to the terminal block Unscrew the four screws on the front of the junction box Before lifting the cover gently rock it to break the seal Gently lift the cover away from the base of the enclosure to gain access to the interior Note A ground wire connects the cover and the base of the junction box Be careful not to damage it ...

Page 13: ...ss Alarm Bar Follow the local wire color code scheme for your region Note This diagram only shows the connection points for external power and ground For clarity no other wires for the Wireless Alarm Bar are shown Other wires are already connected to the RAEPoint and the rest of the Wireless Alarm Bar Do not alter them or their connections Ground Live Neutral ...

Page 14: ...edundant grounding earth connection is required a threaded post is located on plate for wiring to ground earth Place the round lug from the ground wire over the threaded post and then the split washer flat washer and nut Tighten the nut and then connect the other end of the ground wire to an appropriate grounding location IMPORTANT Prior to factory shipment the Wireless Alarm Bar is tested However...

Page 15: ...ft 300m typical IP Rating IP 65 Mechanical Interface 3 4 NPT Male Installation 2 pipe holding or wall mounting Temperature 4 F to 104 F 20 C to 40 C Certified Humidity 0 to 95 relative humidity non condensing Pressure 90 to 110kPa Status Indicators 4 LEDs Network Alarm Communication Mode Dimensions 17 95 L x 18 75 W x 6 9 H 456 x 476 x 173 mm Housing Material Aluminum Weight 26 5 lbs 12 kg Safety ...

Page 16: ... x 18 75 W x 6 9 H 456 x 476 x 173 mm Housing Material Aluminum Weight 26 5 lbs 12 kg Safety Compliance ATEX II 3G Ex T2 G c Zone 2 UL Class I Division 2 Group A B C D Wireless Certification FCC Part 15 R TTE directive 1999 5 EC Contact RAE Systems for other countries Strobes Two 10 Joule xenon strobes yellow red Peak Intensity 19103 Cd yellow 3332 Cd red Material Marine grade LM6 aluminum alloy S...

Page 17: ... ER36636 15 DEALER No HONEYWELL INTERNATIONAL MIDDLE EAST LTD DUBAI BR TRA REGISTERED No ER36063 14 DEALER No HONEYWELL INTERNATIONAL MIDDLE EAST LTD DUBAI BR Hazardous Location Application The Wireless Alarm Bar includes multiple components RAEPoint junction box two strobe lights and one horn The table below shows suitable application based on the components for the combined system US Cl I Div 2 ...

Page 18: ...honeywell com Americas Honeywell Analytics Distribution Inc Tel 1 847 955 8200 Toll free 1 800 538 0363 Fax 1 847 955 8210 detectgas honeywell com RAE Systems by Honeywell Phone 408 952 8200 Toll Free 1 888 723 4800 Fax 408 952 8480 Asia Pacific Honeywell Analytics Asia Pacific Tel 82 0 2 6909 0300 Fax 82 0 2 2025 0328 India Tel 91 124 4752700 analytics ap honeywell com Technical Services EMEA HAe...