Summary of Contents for Xenon 1500

Page 1: ... Xenon 1500 Area Imaging Scanner User s Guide http manualforhoneywellthermostat com ...

Page 2: ...y information that is protected by copyright All rights are reserved No part of this document may be photocopied repro duced or translated into another language without the prior written consent of HII 2010 2011 Honeywell International Inc All rights reserved Web Address www honeywellaidc com Xenon is a trademark or registered trademark of Honeywell International Inc Microsoft Windows Windows NT W...

Page 3: ... by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio or television technician for help If necessary the user should consult the dealer or an experienced radio te...

Page 4: ...22 2 No 60950 1 07 2nd Edition Europe The CE marking indicates compliance to 2004 108 EC EMC Directive with Standards EN55022 CLASS B EN55024 EN61000 3 2 EN61000 3 3 For further information please contact Honeywell Imaging Mobility Europe BV Nijverheidsweg 9 13 5627 BT Eindhoven The Netherlands Honeywell International Inc shall not be liable for use of our product with equipment i e power supplies...

Page 5: ...more information on the collection reuse and recycling sys tems please contact your local or regional waste administration You may also contact your supplier for more information on the environ mental performances of this product Germany If your product is marked with the GS symbol then the product has been issued a GS certificate showing compliance to EN 60950 1 Second Edition This device is not ...

Page 6: ... have been tested and classified as EXEMPT RISK GROUP to the standard IEC 62471 2006 CB Scheme Certified to CB Scheme IEC 60950 1 Second Edition Patents For patent information please refer to www honeywellaidc com patents Solids and Water Protection The Xenon 1500 has a rating of IP41 immunity of foreign particles and dripping water Warning To reduce the possibility of heat related injuries avoid ...

Page 7: ...Required Safety Labels Scanner Compliance Label location Part Number Serial Number and Revision Information location Illumination output ...

Page 8: ......

Page 9: ... and Play 2 1 USB IBM SurePos 2 1 USB PC or Macintosh Keyboard 2 2 USB HID 2 2 USB Serial 2 2 Keyboard Country Layout 2 4 Keyboard Style 2 10 Keyboard Conversion 2 12 Control Character Output 2 12 Keyboard Modifiers 2 12 Chapter 3 Input Output Settings Power Up Beeper 3 1 Beep on BEL Character 3 1 Trigger Click 3 1 Good Read and Error Indicators 3 2 Beeper Good Read 3 2 Beeper Volume Good Read 3 2...

Page 10: ... 3 10 Reread Delay 3 10 User Specified Reread Delay 3 11 Illumination Lights 3 11 Aimer Delay 3 11 User Specified Aimer Delay 3 12 Scanner Time Out 3 12 Aimer Mode 3 12 Centering 3 12 No Read 3 14 Video Reverse 3 15 Working Orientation 3 15 Chapter 4 Data Editing Prefix Suffix Overview 4 1 To Add a Prefix or Suffix 4 1 To Clear One or All Prefixes or Suffixes 4 2 To Add a Carriage Return Suffix to...

Page 11: ...ds 5 5 Miscellaneous Commands 5 6 Data Formatter 5 7 Primary Alternate Data Formats 5 8 Chapter 6 Symbologies All Symbologies 6 2 Message Length Description 6 2 Codabar 6 3 Codabar Concatenation 6 4 Code 39 6 6 Full ASCII 6 8 Code 39 Code Page 6 9 Interleaved 2 of 5 6 10 NEC 2 of 5 6 11 Code 93 6 13 Code 93 Code Page 6 14 Straight 2 of 5 Industrial three bar start stop 6 15 Straight 2 of 5 IATA tw...

Page 12: ...36 Codablock F 6 37 PDF417 6 38 MacroPDF417 6 39 MicroPDF417 6 39 GS1 Composite Codes 6 40 UPC EAN Version 6 40 GS1 Emulation 6 41 TCIF Linked Code 39 TLC39 6 42 QR Code 6 43 QR Code Page 6 44 Data Matrix 6 45 Data Matrix Code Page 6 46 Aztec Code 6 47 Aztec Code Page 6 48 Chinese Sensible Han Xin Code 6 49 Postal Codes Linear 6 49 China Post Hong Kong 2 of 5 6 49 Korea Post 6 51 Chapter 7 Interfa...

Page 13: ...ing from the Web 8 4 Chapter 9 Serial Programming Commands Conventions 9 1 Menu Command Syntax 9 1 Query Commands 9 2 Responses 9 2 Trigger Commands 9 4 Resetting the Custom Defaults 9 4 Menu Commands 9 5 Chapter 10 Product Specifications 1500 Scanner Product Specifications 10 1 Depth of Field Chart 10 2 Standard USB Cable Pinout 10 3 Chapter 11 Maintenance Repairs 11 1 Maintenance 11 1 Cleaning t...

Page 14: ...lacing an Interface Cable 11 3 Troubleshooting a Xenon Scanner 11 3 Chapter 12 Customer Support Appendix A Reference Charts Symbology Chart A 1 ASCII Conversion Chart Code Page 1252 A 4 Code Page Mapping of Printed Bar Codes A 6 Unicode Key Maps A 8 ...

Page 15: ... terminal and communications settings If you need to change these settings programming is accomplished by scanning the bar codes in this guide An asterisk next to an option indicates the default setting Unpacking Your Device After you open the shipping carton containing the product take the following steps Check for damage during shipment Report damage immediately to the carrier who delivered the ...

Page 16: ...e interface cable to the device first then to the computer Reading Techniques The scanner has a view finder that projects a bright red aiming beam that corre sponds to the scanner s horizontal field of view The aiming beam should be centered over the bar code but it can be positioned in any direction for a good read ...

Page 17: ...opriate dis tance from the target pull the trigger and center the aiming beam on the sym bol If the code being scanned is highly reflective e g laminated it may be necessary to tilt the code up 15 to 18 to prevent unwanted reflection Setting Custom Defaults You have the ability to create a set of menu commands as your own custom defaults To do so scan the Set Custom Defaults bar code below before ...

Page 18: ...bar code then scan the Beeper Volume High menu code and then Save Custom Defaults The rest of the custom defaults will remain but the beeper volume setting will be updated Resetting the Custom Defaults If you want the custom default settings restored to your scanner scan the Acti vate Custom Defaults bar code below This is the recommended default bar code for most users It resets the scanner to th...

Page 19: ...om Defaults bar code then scan Activate Defaults This resets the scanner to the factory default settings The Menu Commands beginning on page 9 5 list the factory default settings for each of the commands indicated by an asterisk on the programming pages This selection erases all your settings and resets the scanner to the original factory defaults It also disables all plugins Remove Custom Default...

Page 20: ...1 6 ...

Page 21: ...y codes to program the scanner for an IBM SurePos USB handheld scanner or IBM SurePos USB tabletop scanner interface Note After scanning one of these codes you must power cycle the cash register Each bar code above also programs the following suffixes for each symbol ogy Symbology Suffix Symbology Suffix EAN 8 0C Code 39 00 0A 0B EAN 13 16 Interleaved 2 of 5 00 0D 0B UPC A 0D Code 128 00 18 0B UPC...

Page 22: ... program the scanner to emulate a regular RS232 based COM Port If you are using a Microsoft Windows PC you will need to download a driver from the Honeywell website www honeywellaidc com The driver will use the next available COM Port number Apple Macintosh computers recognize the scanner as a USB CDC class device and automatically uses a class driver Note No extra configuration e g baud rate is n...

Page 23: ...2 3 CTS RTS Emulation ACK NAK Mode CTS RTS Emulation On CTS RTS Emulation Off ACK NAK Mode On ACK NAK Mode Off ...

Page 24: ... or language As a general rule the following characters are sup ported but need special care for countries other than the United States United States United States Dvorak left United States International Albania Azeri Cyrillic Azeri Latin Belarus Belgium United States Dvorak United States Dvorak right Bosnia Brazil ...

Page 25: ...eyboard Country continued Bulgaria Latin Canada French Canada Multilingual Croatia Czech Czech Programmers Czech QWERTY Czech QWERTZ Bulgaria Cyrillic Canada French legacy Brazil MS Denmark Dutch Netherlands ...

Page 26: ...2 6 Keyboard Country continued Finland Gaelic Germany Greek Greek 220 Latin Greek 220 Greek 319 Latin Greek 319 Faeroese France Estonia Greek Latin Greek MS ...

Page 27: ...2 7 Keyboard Country continued Italian 142 Hungarian 101 key Iceland Irish Italy Japan ASCII Kazakh Kyrgyz Cyrillic Hebrew Hungary Greek Polytonic Latin America Latvia ...

Page 28: ...2 8 Keyboard Country continued Lithuania IBM Malta Mongolian Cyrillic Norway Poland Polish 214 Polish Programmers Portugal Lithuania Macedonia Latvia QWERTY Romania Russia ...

Page 29: ...2 9 Keyboard Country continued SCS Serbia Latin Slovakia Slovakia QWERTY Slovakia QWERTZ Slovenia Spain Spanish variation Russian Typewriter Serbia Cyrillic Russian MS Sweden Switzerland French ...

Page 30: ...If you have used Keyboard Conversion settings they will override any of the following Key board Style settings Default Regular Turkey F Ukrainian United Kingdom United Stated Dvorak right United States Dvorak left United States Dvorak United States International Uzbek Cyrillic Tatar Turkey Q Switzerland German ...

Page 31: ...e tracks and reflects if you have Caps Lock on or off This selection can only be used with systems that have an LED that notes the Caps Lock sta tus AT keyboards Autocaps via NumLock bar code should be scanned in countries e g Ger many France where the Caps Lock key cannot be used to toggle Caps Lock The NumLock option works similarly to the regular Autocaps but uses the Num Lock key to retrieve t...

Page 32: ...n sends a text string instead of a control character For example when the control character for a carriage return is expected the output would display CR instead of the ASCII code of 0D Refer to ASCII Conversion Chart Code Page 1252 on page A 4 Only codes 00 through 1F are converted the first column of the chart Note Control ASCII Mode overrides this mode Default Off Keyboard Modifiers This modifi...

Page 33: ... Relationships page 7 1 for CTRL ASCII Values Windows Mode Prefix Suffix Off The scanner sends key combinations for ASCII control characters for values 00 1F but it does not transmit any prefix or suffix information Default Control ASCII Mode Off Turbo Mode The scanner sends characters to a terminal faster If the terminal drops characters do not use Turbo Mode Default Off Windows Mode Control ASCI...

Page 34: ...2 14 Numeric Keypad Mode Sends numeric characters as if entered from a numeric keypad Default Off Numeric Keypad Mode On Numeric Keypad Mode Off ...

Page 35: ...Beep on BEL On bar code below the scanner will beep every time a BEL character is received from the host Default Beep on BEL Off Trigger Click To hear an audible click every time the scanner trigger is pressed scan the Trigger Click On bar code below Scan the Trigger Click Off code if you don t wish to hear the click This feature has no effect on serial or automatic trigger ing Default Trigger Cli...

Page 36: ...s option off only turns off the beeper response to a good read indication All error and menu beeps are still audible Default Beeper Good Read On Beeper Volume Good Read The beeper volume codes modify the volume of the beep the scanner emits on a good read Default Medium Beeper Good Read On Beeper Good Read Off High Medium Off Low ...

Page 37: ...per pitch codes modify the pitch frequency of the sound the scan ner emits when there is a bad read or error Default Razz Beeper Duration Good Read The beeper duration codes modify the length of the beep the scanner emits on a good read Default Normal Low 1600 Hz Medium 2700 Hz High 4200 Hz Razz 250 Hz Medium 3250 Hz High 4200 Hz Normal Beep Short Beep Short Beep ...

Page 38: ...r code below and then scan a digit 1 9 bar code and the Save bar code on the Programming Chart inside the back cover of this manual Default 1 Number of Beeps Error The number of beeps and LED flashes emitted by the scanner for a bad read or error can be programmed from 1 9 For example if you program this option to have five error beeps there will be five error beeps and five LED flashes in respons...

Page 39: ...the scanner scans until a bar code is read or until the trigger is released Default Manual Trigger Normal Serial Trigger Mode You can activate the scanner either by pressing the trigger or using a serial trig ger command see Trigger Commands on page 9 4 When in serial mode the scanner scans until a bar code has been read or until the deactivate command is sent The scanner can also be set to turn i...

Page 40: ...ck cover then scanning Save Default 30 000 ms Presentation Mode Presentation Mode uses ambient light to detect bar codes The LEDs remain off until a bar code is presented to the scanner then the LEDs turn on automat ically to read the code If the light level in the room is not high enough Presen tation Mode may not work properly Presentation LED Behavior after Decode When a scanner is in presentat...

Page 41: ...e the scanner reads only those bar codes intended by the user For instance if multiple codes are placed closely together Presentation Centering will insure that only the desired codes are read Note To adjust centering when the scanner is hand held see Centering page 3 12 If a bar code is not touched by a predefined window it will not be decoded or output by the scanner If Presentation Centering is...

Page 42: ...s through the centering window it will be read Bar Code 2 does not pass through the centering window so it will not be read Note A bar code needs only to be touched by the centering window in order to be read It does not need to pass completely through the centering window 0 Bar Code 1 Bar Code 2 10 20 30 40 50 60 70 80 90 100 100 90 80 70 60 50 40 30 20 10 0 ...

Page 43: ...imized to read bar codes from mobile phone or other LED displays However the speed of scanning printed bar codes may be slightly lower when this mode is enabled You can enable Mobile Phone Reading for either a hand held device or for a hands free pre sentation application Note To turn off Mobil Phone Read Mode scan a Manual or Serial Trigger Mode bar code see page 3 5 Left of Presentation Centerin...

Page 44: ...can the Hands Free Time Out bar code then scan the time out duration from 0 300 000 milliseconds from the inside back cover and Save Default 5 000 ms Reread Delay This sets the time period before the scanner can read the same bar code a sec ond time Setting a reread delay protects against accidental rereads of the same bar code Longer delays are effective in minimizing accidental rereads Use short...

Page 45: ...hts off scan the Lights Off bar code Default Lights On Note This setting does not affect the aimer light The aiming light can be set using Aimer Mode page 3 12 Aimer Delay The aimer delay allows a delay time for the operator to aim the scanner before the picture is taken Use these codes to set the time between when the trigger is pulled and when the picture is taken During the delay time the aimin...

Page 46: ...om 0 999 999 ms from the inside back cover then scanning Save Default 1 ms Aimer Mode This feature allows you to turn the aimer on and off When the Interlaced bar code is scanned the aimer is interlaced with the illumination LEDs Default Interlaced Centering Use Centering to narrow the scanner s field of view to make sure that when the scanner is hand held it reads only those bar codes intended by...

Page 47: ...pass through the centering window you specify using the Top of Centering Window Bottom of Centering Window Left and Right of Centering Window bar codes In the example below the white box is the centering window The centering win dow has been set to 20 left 30 right 8 top and 25 bottom Since Bar Code 1 passes through the centering window it will be read Bar Code 2 does not pass through the centerin...

Page 48: ... On the scanner notifies you if a code cannot be read If using an EZConfig Scanning Tool Scan Data Window see page 8 3 an NR appears when a code cannot be read If No Read is turned Off the NR will not appear Default Off If you want a different notation than NR for example Error or Bad Code you can edit the output message see Data Formatting beginning on page 5 1 The hex code for the No Read symbol...

Page 49: ...eo Reverse Only menu bar codes cannot be read You must scan Video Reverse Off or Video Reverse and Standard Bar Codes in order to read menu bar codes Working Orientation Some bar codes are direction sensitive Use the working orientation settings if your direction sensitive codes will not usually be presented upright to the scan ner Default Upright Video Reverse Only Video Reverse Off VIDREV0 Video...

Page 50: ...3 16 Default Upright Upright Upside Down Vertical Top to Bottom Vertical Bottom to Top ...

Page 51: ...ault suffix None A prefix or suffix may be added or cleared from one symbology or all symbologies You can add any prefix or suffix from the ASCII Conversion Chart Code Page 1252 beginning on page A 4 plus Code I D and AIM I D You can string together several entries for several symbologies at one time Enter prefixes and suffixes in the order in which you want them to appear on the output When setti...

Page 52: ...thout saving Repeat Steps 1 6 to add a prefix or suffix for another symbology Example Add a Suffix to a specific symbology To send a CR carriage return Suffix for U P C only Step 1 Scan Add Suffix Step 2 Determine the 2 digit hex value from the Symbology Chart included in the Symbology Chart beginning on page A 1 for U P C Step 3 Scan 6 3 from the Programming Chart inside the back cover of this ma...

Page 53: ...e from the Programming Chart inside the back cover of this manual or scan 9 9 for all symbologies Your change is automatically saved To Add a Carriage Return Suffix to All Symbologies Scan the following bar code if you wish to add a carriage return suffix to all symbologies at once This action first clears all current suffixes then pro grams a carriage return suffix for all symbologies Prefix Sele...

Page 54: ... these function codes are provided in Supported Interface Keys starting on page 7 3 Default Enable Intercharacter Interfunction and Intermessage Delays Some terminals drop information characters if data comes through too quickly Intercharacter interfunction and intermessage delays slow the transmission of data increasing data integrity Add Suffix Clear One Suffix Clear All Suffixes Enable Disable ...

Page 55: ...ercharacter Delay An intercharacter delay of up to 5000 milliseconds in 5ms increments may be placed after the transmission of a particular character of scanned data Scan the Delay Length bar code below then scan the number of 5ms delays and the Save bar code using the Programming Chart inside the back cover of this manual Next scan the Character to Trigger Delay bar code then the 2 digit hex valu...

Page 56: ...side the back cover of this manual Intermessage Delay An intermessage delay of up to 5000 milliseconds in 5ms increments may be placed between each scan transmission Scan the Intermessage Delay bar code below then scan the number of 5ms delays and the Save bar code using the Programming Chart inside the back cover of this man ual To remove this delay scan the Intermessage Delay bar code then set t...

Page 57: ...3 Specific Terminal ID Universal Code ID Actual Length 4 Specific Terminal ID Universal Code ID Universal Length 5 Universal Terminal ID Actual Code ID Actual Length 6 Universal Terminal ID Actual Code ID Universal Length 7 Universal Terminal ID Universal Code ID Actual Length 8 Universal Terminal ID Universal Code ID Universal Length The maximum size of a data format configuration is 2000 bytes w...

Page 58: ...the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart inside the back cover of this manual Step 5 Length Specify what length up to 9999 characters of data will be acceptable for this symbology Scan the four digit data length from the Programming Chart inside the back cover of this manual Note 50 characters is entered as 0050 9999 is a universal number indicatin...

Page 59: ... scan 1 2 or 3 depending on the format you are clearing Scan the Terminal Type and Code I D see Symbology Chart on page A 1 and the bar code data length for the specific data format that you want to delete All other formats remain unaffected Clear all Data Formats This clears all data formats Save to exit and save your data format changes Discard to exit without saving any data format changes Clea...

Page 60: ...x stands for the the insert character s hex value for its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 beginning on page A 4 for decimal hex and character codes Send all characters up to a particular character F3 Include in the output message all characters from the input message starting with the character at the current cursor position and continuing to but not including the sea...

Page 61: ...d a number of characters F5 Move the cursor ahead nn characters from current cursor position Syntax F5nn where nn is the numeric value 00 99 for the number of characters the cursor should be moved ahead Move the cursor backward a number of characters F6 Move the cursor back nn characters from current cursor position Syntax F6nn where nn is the numeric value 00 99 for the number of characters the c...

Page 62: ...ax E7xx where xx stands for the search character s hex value for its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 beginning on page A 4 for decimal hex and character codes Miscellaneous Commands Suppress characters FB Suppress all occurrences of up to 15 different characters starting at the current cursor position as the cursor is advanced by other commands When the FC command is ...

Page 63: ...haracter is numeric Insert a delay EF Inserts a delay of up to 49 995 milliseconds in multiples of 5 starting from the current cursor position Syntax EFnnnn where nnnn stands for the delay in 5ms increments up to 9999 This command can only be used with keyboard emulation Data Formatter When Data Formatter is turned Off the bar code data is output to the host as read including prefixes and suffixes...

Page 64: ... switch between these formats Your primary data format is saved under 0 Your other three formats are saved under 1 2 and 3 To set your device to use one of these formats scan one of the bar codes below Data Formatter On Not Required Data Format Required Primary Data Format Data Format 1 Data Format 2 Data Format 3 ...

Page 65: ...of 5 Codabar MicroPDF417 Codablock A MSI Codablock F NEC 2 of 5 Code 128 Postal Codes Linear Code 39 PDF417 Code 93 GS1 DataBar Omnidirectional Data Matrix QR Code EAN JAN 13 Straight 2 of 5 IATA two bar start stop EAN JAN 8 Straight 2 of 5 Industrial three bar start stop GS1 Composite Codes TCIF Linked Code 39 TLC39 GS1 DataBar Expanded UPC A GS1 DataBar Limited UPC A EAN 13 with Extended Coupon ...

Page 66: ... scanner will issue an error tone You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data This helps reduce the chances of a misread EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15Max length 15 For a value o...

Page 67: ...rs are created using different modulos You can program the scanner to read only Codabar bar codes with Modulo 16 check characters Default No Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character When Check Character is set to Validate and Transmit the scanner will only read Codabar bar codes printed with a check character ...

Page 68: ...nner looks for a Codabar symbol having a D start character adjacent to a symbol having a D stop character In this case the two mes sages are concatenated into one with the D characters omitted Select Require to prevent the scanner from decoding a single D Codabar symbol without its companion This selection has no effect on Codabar symbols without Stop Start D characters No Check Character Validate...

Page 69: ...e bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 2 60 Minimum Default 4 Maximum Default 60 Minimum Message Length Maximum Message Length ...

Page 70: ...Start Stop characters Default Don t Transmit Code 39 Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character When Check Character is set to Validate but Don t Transmit the unit only reads Code 39 bar codes printed with a check character but will not transmit the check character with the scanned data On Off Transmit Don t Tra...

Page 71: ...length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 0 48 Minimum Default 0 Maximum Default 48 Code 39 Append This function allows the scanner to append the data from several Code 39 bar codes together before transmitting them to the host computer When the scanner encounters a Code 39 bar code with the append trigger char No Check Character Va...

Page 72: ... ASCII character SYN and C will be decoded as the ASCII character Default Off NUL U DLE P SP SPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 R B 2 2 B B R R b B r R ETX C DC3 S C 3 3 C C S S c C s S EOT D DC4 T D 4 4 D D T T d D t T ENQ E NAK U E 5 5 E E U U e E u U ACK F SYN V F 6 6 F F V V f F v V BEL G ETB W G 7 7 G G W W g G w W BS H CAN X H 8 8 H H X X h H x X HT I EM Y I 9 ...

Page 73: ...use the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see Code Page Mapping of Printed Bar Codes on page A 6 and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual The data...

Page 74: ...ate but Don t Transmit the unit only reads Interleaved 2 of 5 bar codes printed with a check digit but will not transmit the check digit with the scanned data When Check Digit is set to Validate and Transmit the scanner only reads Interleaved 2 of 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit On Off Validate but Don t Tran...

Page 75: ... Default 80 NEC 2 of 5 Default All NEC 2 of 5 Settings NEC 2 of 5 On Off Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit When Check Digit is set to Validate but Don t Transmit the unit only reads NEC 2 of 5 bar codes printed with a check digit but will not transmit the check digit with the scanned data Minimum Message Length Max...

Page 76: ...e scanned data Default No Check Digit NEC 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 No Check Digit Validate and Transmit Validate but Don t Transmit Minimum Message Length Maximum Message Length ...

Page 77: ...ault 0 Maximum Default 80 Code 93 Append This function allows the scanner to append the data from several Code 93 bar codes together before transmitting them to the host computer When this function is enabled the scanner stores those Code 93 bar codes that start with a space excluding the start and stop symbols and does not immediately transmit the data The scanner stores the data in the order in ...

Page 78: ... display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see Code Page Mapping of Printed Bar Codes on page A 6 and scan the value and the Save bar code from the Programming Chart on...

Page 79: ...of 5 Industrial On Off Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 On Off Minimum Message Length Maximum Message Length ...

Page 80: ...f 5 IATA On Off Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Off On Minimum Message Length Maximum Message Length ...

Page 81: ...atrix 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 On Off Maximum Message Length Minimum Message Length ...

Page 82: ...es a paid license The ISBT 128 Application Specification describes 1 the critical data elements for labeling blood prod ucts 2 the current recommendation to use Code 128 due to its high degree of security and its space efficient design 3 a variation of Code 128 that supports concatenation of neighboring symbols and 4 the standard layout for bar codes on a blood product label Use the bar codes belo...

Page 83: ...er The data is then transmitted in the order in which the bar codes were read FIFO Default Off Code 128 Code Page Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case sc...

Page 84: ... Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 80 Minimum Default 1 Maximum Default 80 On Off Minimum Message Length Maximum Message Length ...

Page 85: ...whether the check digit should be transmitted at the end of the scanned data or not Default On UPC A Number System The numeric system digit of a U P C symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will not transmit it Default On On Off On Off Off On ...

Page 86: ...y read UPC A bar codes that have addenda You must then turn on a 2 or 5 digit addenda listed on page 6 22 Default Not Required UPC A Addenda Separator When this feature is on there is a space between the data from the bar code and the data from the addenda When turned off there is no space Default On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required Require...

Page 87: ...logies Otherwise it transmits the first coupon code it reads If you scan the Require Concatenation code the scanner must see and read the coupon code and extended coupon code in a single read to transmit the data No data is output unless both codes are read Default Off Coupon GS1 DataBar Output If you scan coupons that have both UPC and GS1 DataBar codes you may wish to scan and output only the da...

Page 88: ...th the 0 number system To read these codes use the UPC E0 On selection If you need to read codes that lead with the 1 number system use UPC E1 page 6 27 Default On UPC E0 Expand UPC E Expand expands the UPC E code to the 12 digit UPC A format Default Off UPC E0 On UPC E0 Off On Off ...

Page 89: ...0 Addenda Separator When this feature is On there is a space between the data from the bar code and the data from the addenda When turned Off there is no space Default On UPC E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not Default On Not Required Required Off On Off On ...

Page 90: ...data but the unit can be programmed so it will not transmit it To prevent transmission scan Off Default On UPC E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC E data Default Off for both 2 Digit and 5 Digit Addenda Off On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On ...

Page 91: ...es that lead with the 1 number system use the UPC E1 On selection Default Off EAN JAN 13 Default All EAN JAN Settings EAN JAN 13 On Off EAN JAN 13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On UPC E1 On UPC E1 Off On Off Off On ...

Page 92: ...3 data Default Off for both 2 Digit and 5 Digit Addenda EAN JAN 13 Addenda Required When Required is scanned the scanner will only read EAN JAN 13 bar codes that have addenda Default Not Required 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required Required ...

Page 93: ...om the addenda When turned Off there is no space Default On Note If you want to enable or disable EAN13 with Extended Coupon Code refer to UPC A EAN 13 with Extended Coupon Code page 6 23 ISBN Translate When On is scanned EAN 13 Bookland symbols are translated into their equivalent ISBN number format Default Off Off On Off On ...

Page 94: ... Default All EAN JAN 8 Settings EAN JAN 8 On Off EAN JAN 8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On On Off Off On ...

Page 95: ...red is scanned the scanner will only read EAN JAN 8 bar codes that have addenda Default Not Required EAN JAN 8 Addenda Separator When this feature is On there is a space between the data from the bar code and the data from the addenda When turned Off there is no space Default On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required Required Off On ...

Page 96: ...ogram the scanner to read MSI bar codes with Type 10 check charac ters Default Validate Type 10 but Don t Transmit When Check Character is set to Validate Type 10 11 and Transmit the scanner will only read MSI bar codes printed with the specified type check character s and will transmit the character s at the end of the scanned data On Off ...

Page 97: ... length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 Validate Type 10 and Transmit Validate Type 10 but Don t Transmit Validate 2 Type 10 Characters but Don t Transmit Validate 2 Type 10 Characters and Transmit Validate Type 10 then Type 11 Character but Don t Transmit Validate Type 10 then Type 11 Ch...

Page 98: ... DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings GS1 DataBar Omnidirectional On Off GS1 DataBar Limited Default All GS1 DataBar Limited Settings GS1 DataBar Limited On Off On Off On Off ...

Page 99: ...n Off GS1 DataBar Expanded Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 4 74 Minimum Default 4 Maximum Default 74 On Off Minimum Message Length Maximum Message Length ...

Page 100: ...block A Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 600 Minimum Default 1 Maximum Default 600 On Off Minimum Message Length Maximum Message Length ...

Page 101: ...lock F Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 2048 Minimum Default 1 Maximum Default 2048 On Off Minimum Message Length Maximum Message Length ...

Page 102: ...sage Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Mini mum and Maximum lengths 1 2750 Minimum Default 1 Maximum Default 2750 On Off Maximum Message Length Minimum Message Length ...

Page 103: ...capable of encoding very large amounts of data into multiple PDF417 bar codes When this selection is enabled these multiple bar codes are assembled into a single data string Default On MicroPDF417 Default All MicroPDF417 Settings MicroPDF417 On Off On Off Off On ...

Page 104: ... for the co existence of symbologies already in use Default Off UPC EAN Version Scan the UPC EAN Version On bar code to decode GS1 Composite sym bols that have a U P C or an EAN linear component This does not affect GS1 Composite symbols with a GS1 128 or GS1 linear component Default UPC EAN Version Off Note If you scan coupons that have both UPC and GS1 DataBar codes you may wish to scan and outp...

Page 105: ...nize one data carrier type If GS1 128 Emulation is scanned all retail codes U P C UPC E EAN8 EAN13 are expanded out to 16 digits If the AIM ID is enabled the value will be the GS1 128 AIM ID C1 see Symbology Chart on page A 1 If GS1 DataBar Emulation is scanned all retail codes U P C UPC E EAN8 EAN13 are expanded out to 16 digits If the AIM ID is enabled the value will be the GS1 DataBar AIM ID em...

Page 106: ...d code component All bar code readers are capable of reading the Code 39 linear component The MicroPDF417 component can only be decoded if TLC39 On is selected The linear component may be decoded as Code 39 even if TLC39 is off Default Off GS1 DataBar Emulation GS1 128 Emulation GS1 Emulation Off GS1 Code Expansion Off EAN8 to EAN13 Conversion Off On ...

Page 107: ...dditional information Mini mum and Maximum lengths 1 7089 Minimum Default 1 Maximum Default 7089 QR Code Append This function allows the scanner to append the data from several QR Code bar codes together before transmitting them to the host computer When the scanner encounters an QR Code bar code with the append trigger character s it buffers the number of QR Code bar codes determined by On Off Ma...

Page 108: ...per characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see Code Page Mapping of Printed Bar Codes on page A 6 and scan the value and the Save bar code from the Programming Chart on the inside the back ...

Page 109: ...i mum and Maximum lengths 1 3116 Minimum Default 1 Maximum Default 3116 Data Matrix Append This function allows the scanner to append the data from several Data Matrix bar codes together before transmitting them to the host computer When the scanner encounters an Data Matrix bar code with the append trigger character s it buffers the number of Data Matrix bar codes deter Off On Maximum Message Len...

Page 110: ...cting If this is the case scan the bar code below select the code page with which the bar codes were created see Code Page Mapping of Printed Bar Codes on page A 6 and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual The data characters should then appear properly Low Density Data Matrix If you are reading low density Data Matrix codes cod...

Page 111: ...e 6 2 for additional information Mini mum and Maximum lengths 1 3832 Minimum Default 1 Maximum Default 3832 Aztec Append This function allows the scanner to append the data from several Aztec bar codes together before transmitting them to the host computer When the scanner encounters an Aztec bar code with the append trigger charac Off On Maximum Message Length Minimum Message Length ...

Page 112: ...ed does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see Code Page Mapping of Printed Bar Codes on page A 6 and scan the value and the Save bar code from the Programmi...

Page 113: ...th Description page 6 2 for additional information Mini mum and Maximum lengths 1 7833 Minimum Default 1 Maximum Default 7833 Postal Codes Linear The following lists linear postal codes Any combination of linear postal code selections can be active at a time China Post Hong Kong 2 of 5 Default All China Post Hong Kong 2 of 5 Settings Off On Maximum Message Length Minimum Message Length ...

Page 114: ... 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maxi mum Default 80 On Off Minimum Message Length Maximum Message Length ...

Page 115: ...tion page 6 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maxi mum Default 48 Korea Post Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data Default Don t Transmit On Off Minimum Message Length Maximum Message Length Don t Transmit Check Digit Transmit Check Digit ...

Page 116: ...6 52 ...

Page 117: ...used with the scanner Refer to page 2 13 enable Control ASCII mode Function Code HEX ASCII Value Full ASCII CTRL NUL 00 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G BS 08 H HT 09 I LF 0A J VT 0B K FF 0C L CR 0D M SO 0E N SI 0F O DLE 10 P DC1 11 Q DC2 12 R DC3 13 S DC4 14 T NAK 15 U SYN 16 V ETB 17 W CAN 18 X EM 19 Y SUB 1A Z ESC 1B FS 1C GS 1D RS 1E US 1F _ ...

Page 118: ...ply to US only The following chart indicates the equivalents of these five characters for different countries Country Codes United States 6 Belgium 6 Scandinavia 8 9 6 France 8 6 Germany à 6 Italy 6 Switzerland 6 United Kingdom 6 Denmark 8 9 6 Norway 8 9 6 Spain 6 ...

Page 119: ... 06 CTRL break CNTRL break BEL 07 CR Enter RETURN BS 08 Reserved APPLE make HT 09 Tab TAB LF 0A Reserved APPLE break VT 0B Tab TAB FF 0C Delete Del CR 0D CR Enter RETURN SO 0E Insert Ins Help SI 0F Escape ESC DLE 10 F11 F11 DC1 11 Home Home DC2 12 Print Prnt Scrn DC3 13 Back Space BACKSPACE DC4 14 Back Tab LSHIFT TAB NAK 15 F12 F12 SYN 16 F1 F1 ETB 17 F2 F2 CAN 18 F3 F3 EM 19 F4 F4 SUB 1A F5 F5 ES...

Page 120: ...7 4 ...

Page 121: ...ymbologies This is a temporary setting that will be removed when the unit is power cycled Show Decoder Revision Scan the bar code below to output the decoder revision Show Scan Driver Revision Scan the bar code below to output the scan driver revision The scan driver controls image capture Show Software Revision Scan the bar code below to output the current software revision unit serial num ber an...

Page 122: ...in addition the content of that program ming code is output to the terminal Note This feature should not be used during normal scanner operation TotalFreedom TotalFreedom is an open system architecture that makes it possible for you cre ate applications that reside on your scanner Decoding apps and Data Format ting apps can be created using TotalFreedom For further information about TotalFreedom g...

Page 123: ...red you can create a single bar code that contains all the customized programming parameters and mail or fax that bar code to any location Users in other locations can scan the bar code to load in the customized programming To communicate with a scanner EZConfig Scanning requires that the PC have at least one available serial communication port or a serial port emulation using a physical USB port ...

Page 124: ...cf file Installing EZConfig Scanning from the Web Note EZConfig Scanning requires NET software If NET is not installed on your PC you will be prompted to install it during the EZConfig Scanning installation 1 Access the Honeywell web site at www honeywellaidc com 2 Click on the Resources tab Select Software 3 Click on the dropdown for Select Product Number Click on 1500 4 Click on the listing for ...

Page 125: ...ubTag Data SubTag Data Tag SubTag Data Storage Prefix Three ASCII characters SYN M CR ASCII 22 77 13 Name To send information to the scanner use Xenon The default factory setting for a Xenon scanner is Xenon scanner This setting is changed by using the BT_NAM command which accepts alphanumeric values If the name is not known a wildcard can be used Tag A 3 character case insensitive field that iden...

Page 126: ...ce of a SubTag field the query applies only to the subset of commands available that match the Tag field In this case the Data field should not be used because it is ignored by the device Data Field Usage When a query is used in place of the Data field the query applies only to the specific command identified by the Tag and SubTag fields Concatenation of Multiple Commands Multiple commands can be ...

Page 127: ...indicates that Codabar Coding Enable CBRENA has a range of values from 0 to 1 off and on Example What is the default value for Codabar Coding Enable Enter cbrena Response CBRENA1 ACK This response indicates that the default setting for Codabar Coding Enable CBRENA is 1 or on Example What is the device s current setting for Codabar Coding Enable Enter cbrena Response CBRENA1 ACK This response indic...

Page 128: ...ans until a bar code has been read until the deactivate com mand is sent or until the serial time out has been reached see Read Time Out on page 3 6 for a description and the serial command on page 9 11 Resetting the Custom Defaults If you want the custom default settings restored to your scanner scan the Acti vate Custom Defaults bar code below This resets the scanner to the custom default settin...

Page 129: ...EFALT 1 5 Programming the Interface Plug and Play Codes IBM SurePos USB IBM SurePos Handheld PAPSPH 2 1 USB IBM SurePos Tabletop PAPSPT 2 1 Plug and Play Codes USB USB Keyboard PC PAP124 2 2 USB Keyboard Mac PAP125 2 2 USB Japanese Keyboard PC TRMUSB134 2 2 USB HID PAP131 2 2 USB Serial TRMUSB130 2 2 CTS RTS Emulation On USBCTS1 2 3 CTS RTS Emulation Off USBCTS0 2 3 ACK NAK Mode On USBACK1 2 3 ACK...

Page 130: ...Czech Programmers KBDCTY40 2 5 Czech QWERTY KBDCTY39 2 5 Czech QWERTZ KBDCTY38 2 5 Denmark KBDCTY8 2 5 Dutch Netherlands KBDCTY11 2 5 Estonia KBDCTY41 2 6 Faeroese KBDCTY83 2 6 Finland KBDCTY2 2 6 France KBDCTY3 2 6 Gaelic KBDCTY84 2 6 Germany KBDCTY4 2 6 Greek KBDCTY17 2 6 Greek 220 Latin KBDCTY64 2 6 Greek 220 KBDCTY61 2 6 Greek 319 Latin KBDCTY65 2 6 Greek 319 KBDCTY62 2 6 Greek Latin KBDCTY63 ...

Page 131: ...TY42 2 7 Latvia QWERTY KBDCTY43 2 8 Lithuania KBDCTY44 2 8 Lithuania IBM KBDCTY45 2 8 Macedonia KBDCTY34 2 8 Malta KBDCTY74 2 8 Mongolian Cyrillic KBDCTY86 2 8 Norway KBDCTY9 2 8 Poland KBDCTY20 2 8 Polish 214 KBDCTY57 2 8 Polish Programmers KBDCTY58 2 8 Portugal KBDCTY13 2 8 Romania KBDCTY25 2 8 Russia KBDCTY26 2 8 Russian MS KBDCTY67 2 9 Russian Typewriter KBDCTY68 2 9 SCS KBDCTY21 2 9 Serbia Cy...

Page 132: ...2 10 Turkey Q KBDCTY24 2 10 Ukrainian KBDCTY76 2 10 United Kingdom KBDCTY7 2 10 United Stated Dvorak right KBDCTY89 2 10 United States Dvorak left KBDCTY88 2 10 United States Dvorak KBDCTY87 2 10 United States International KBDCTY30 2 10 Uzbek Cyrillic KBDCTY77 2 10 Keyboard Conversion Keyboard Conversion Off KBDCNV0 2 12 Convert all Characters to Upper Case KBDCNV1 2 12 Convert all Characters to ...

Page 133: ... ASCII KBDCAS2 2 13 Windows Mode Prefix Suffix Off KBDCAS3 2 13 Turbo Mode Off KBDTMD0 2 13 Turbo Mode On KBDTMD1 2 13 Numeric Keypad Off KBDNPS0 2 14 Numeric Keypad On KBDNPS1 2 14 Input Output Selections Power Up Beeper Power Up Beeper Off BEPPWR0 3 1 Power Up Beeper On BEPPWR1 3 1 Beep on BEL Character Beep on BEL On BELBEP1 3 1 Beep on BEL Off BELBEP0 3 1 Trigger Click On BEPTRG1 3 1 Off BEPTR...

Page 134: ...uration Good Read Normal Beep BEPBIP0 3 3 Short Beep BEPBIP1 3 3 LED Good Read Off BEPLED0 3 4 On BEPLED1 3 4 Number of Beeps Error 1 BEPERR3 3 4 Range 1 9 BEPERR 3 4 Number of Beeps Good Read 1 BEPRPT1 3 4 Range 1 9 BEPRPT 3 4 Good Read Delay No Delay DLYGRD0 3 5 Short Delay 500 ms DLYGRD500 3 5 Medium Delay 1000 ms DLYGRD1000 3 5 Long Delay 1500 ms DLYGRD1500 3 5 User Specified Good Read Delay R...

Page 135: ...3 9 Left of Presentation Centering Window 40 PDCLFT 3 9 Right of Presentation Centering Window 60 PDCRGT 3 9 Top of Presentation Centering Window 40 PDCTOP 3 9 Bottom of Presentation Centering Window 60 PDCBOT 3 9 Mobile Phone Read Mode Hand Held Scanning Mobile Phone PAPHHC 3 9 Hands Free Time Out Range 0 300 000 ms TRGPTO 3 10 Reread Delay Short 500 ms DLYRRD500 3 10 Medium 750 ms DLYRRD750 3 10...

Page 136: ...imer Mode Off SCNAIM0 3 12 Interlaced SCNAIM2 3 12 Centering Window Centering On DECWIN1 3 14 Centering Off DECWIN0 3 14 Left of Centering Window 40 DECLFT 3 14 Right of Centering Window 60 DECRGT 3 14 Top of Centering Window 40 DECTOP 3 14 Bottom of Centering Window 60 DECBOT 3 14 No Read On SHWNRD1 3 14 Off SHWNRD0 3 14 Video Reverse Video Reverse Only VIDREV1 3 15 Video Reverse and Standard Bar...

Page 137: ...Suffix Add Suffix SUFBK2 4 4 Clear One Suffix SUFCL2 4 4 Clear All Suffixes SUFCA2 4 4 Function Code Transmit Enable RMVFNC0 4 4 Disable RMVFNC1 4 4 Intercharacter Delay Range 0 1000 5ms increments DLYCHR 4 5 User Specified Intercharacter Delay Delay Length 0 1000 5ms increments DLYCRX 4 5 Character to Trigger Delay DLY_XX 4 5 Interfunction Delay Range 0 1000 5ms increments DLYFNC 4 6 Intermessage...

Page 138: ...Data Format ALTFNM0 5 8 Data Format 1 ALTFNM1 5 8 Data Format 2 ALTFNM2 5 8 Data Format 3 ALTFNM3 5 8 Symbologies All Symbologies All Symbologies Off ALLENA0 6 2 All Symbologies On ALLENA1 6 2 Codabar Default All Codabar Settings CBRDFT 6 3 Off CBRENA0 6 3 On CBRENA1 6 3 Codabar Start Stop Char Don t Transmit CBRSSX0 6 3 Transmit CBRSSX1 6 3 Codabar Check Char No Check Char CBRCK20 6 4 Validate Bu...

Page 139: ... Code 39 Check Char No Check Char C39CK20 6 7 Validate But Don t Transmit C39CK21 6 7 Validate and Transmit C39CK22 6 7 Code 39 Message Length Minimum 0 48 0 C39MIN 6 7 Maximum 0 48 48 C39MAX 6 7 Code 39 Append Off C39APP0 6 8 On C39APP1 6 8 Code 39 Full ASCII Off C39ASC0 6 9 On C39ASC1 6 9 Code 39 Code Page C39DCP 6 9 Interleaved 2 of 5 Default All Interleaved 2 of 5 Settings I25DFT 6 10 Off I25E...

Page 140: ...eck Digit No Check Char N25CK20 6 12 Validate But Don t Transmit N25CK21 6 12 Validate and Transmit N25CK22 6 12 NEC 2 of 5 Message Length Minimum 2 80 4 N25MIN 6 12 Maximum 2 80 80 N25MAX 6 12 Code 93 Default All Code 93 Settings C93DFT 6 13 Off C93ENA0 6 13 On C93ENA1 6 15 Code 93 Message Length Minimum 0 80 0 C93MIN 6 13 Maximum 0 80 80 C93MAX 6 13 Code 93 Append On C93APP1 6 14 Off C93APP0 6 1...

Page 141: ...ht 2 of 5 IATA Message Length Minimum 1 48 4 A25MIN 6 16 Maximum 1 48 48 A25MAX 6 16 Matrix 2 of 5 Default All Matrix 2 of 5 Settings X25DFT 6 17 Off X25ENA0 6 17 On X25ENA1 6 17 Matrix 2 of 5 Message Length Minimum 1 80 4 X25MIN 6 17 Maximum 1 80 80 X25MAX 6 17 Code 128 Default All Code 128 Settings 128DFT 6 18 Off 128ENA0 6 18 On 128ENA1 6 18 ISBT Concatenation Off ISBENA0 6 18 On ISBENA1 6 18 C...

Page 142: ...CKX1 6 21 UPC A Number System Off UPANSX0 6 21 On UPANSX1 6 21 UPC A 2 Digit Addenda Off UPAAD20 6 22 On UPAAD21 6 22 UPC A 5 Digit Addenda Off UPAAD50 6 22 On UPAAD51 6 22 UPC A Addenda Required Not Required UPAARQ0 6 22 Required UPAARQ1 6 22 UPC A Addenda Separator Off UPAADS0 6 22 On UPAADS1 6 22 UPC A EAN 13 with Extended Coupon Code Off CPNENA0 6 23 Allow Concatenation CPNENA1 6 23 Require Co...

Page 143: ...EAD21 6 26 2 Digit Addenda Off UPEAD20 6 26 5 Digit Addenda On UPEAD51 6 26 5 Digit Addenda Off UPEAD50 6 26 UPC E1 Off UPEEN10 6 27 On UPEEN11 6 27 EAN JAN 13 Default All EAN JAN Settings E13DFT 6 27 Off E13ENA0 6 27 On E13ENA1 6 27 EAN JAN 13 Check Digit Off E13CKX0 6 27 On E13CKX1 6 27 EAN JAN 13 2 Digit Addenda 2 Digit Addenda On E13AD21 6 28 2 Digit Addenda Off E13AD20 6 28 5 Digit Addenda On...

Page 144: ...KX1 6 30 EAN JAN 8 Addenda 2 Digit Addenda Off EA8AD20 6 31 2 Digit Addenda On EA8AD21 6 31 5 Digit Addenda Off EA8AD50 6 31 5 Digit Addenda On EA8AD51 6 31 EAN JAN 8 Addenda Required Not Required EA8ARQ0 6 31 Required EA8ARQ1 6 31 EAN JAN 8 Addenda Separator Off EA8ADS0 6 31 On EA8ADS1 6 31 MSI Default All MSI Settings MSIDFT 6 32 Off MSIENA0 6 32 On MSIENA1 6 32 Selection Setting Indicates defau...

Page 145: ... 33 Validate Type 10 then Type 11 Char and Transmit MSICHK5 6 33 Disable MSI Check Characters MSICHK6 6 33 MSI Message Length Minimum 4 48 4 MSIMIN 6 33 Maximum 4 48 48 MSIMAX 6 33 GS1 DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings RSSDFT 6 34 Off RSSENA0 6 34 On RSSENA1 6 34 GS1 DataBar Limited Default All GS1 DataBar Limited Settings RSLDFT 6 34 Off RSLENA0 6 34 On RSLE...

Page 146: ...dablock A Msg Length Minimum 1 600 1 CBAMIN 6 36 Maximum 1 600 600 CBAMAX 6 36 Codablock F Default All Codablock F Settings CBFDFT 6 36 Off CBFENA0 6 37 On CBFENA1 6 37 Codablock F Msg Length Minimum 1 2048 1 CBFMIN 6 37 Maximum 1 2048 2048 CBFMAX 6 37 PDF417 Default All PDF417 Settings PDFDFT 6 38 On PDFENA1 6 38 Off PDFENA0 6 38 PDF417 Msg Length Minimum 1 2750 1 PDFMIN 6 38 Maximum 1 2750 2750 ...

Page 147: ...ff COMUPC0 6 40 GS1 Composite Codes Msg Length Minimum 1 2435 1 COMMIN 6 41 Maximum 1 2435 2435 COMMAX 6 41 GS1 Emulation GS1 128 Emulation EANEMU1 6 42 GS1 DataBar Emulation EANEMU2 6 42 GS1 Code Expansion Off EANEMU3 6 42 EAN8 to EAN13 Conversion EANEMU4 6 42 GS1 Emulation Off EANEMU0 6 42 TCIF Linked Code 39 On T39ENA1 6 42 Off T39ENA0 6 42 QR Code Default All QR Code Settings QRCDFT 6 49 On QR...

Page 148: ... 3116 3116 IDMMAX 6 45 Data Matrix Append On IDMAPP1 6 46 Off IDMAPP0 6 46 Data Matrix Code Page Data Matrix Code Page 51 IDMDCP 6 46 Low Density Data Matrix Low Density Codes On IDMBST1 6 46 Low Density Codes Off IDMBST0 6 46 Aztec Code Default All Aztec Code Settings AZTDFT 6 47 On AZTENA1 6 47 Off AZTENA0 6 47 Aztec Code Msg Length Minimum 1 3832 1 AZTMIN 6 47 Maximum 1 3832 3832 AZTMAX 6 47 Az...

Page 149: ...ll China Post Hong Kong 2 of 5 Settings CPCDFT 6 49 Off CPCENA0 6 50 On CPCENA1 6 50 China Post Hong Kong 2 of 5 Msg Length Minimum 2 80 4 CPCMIN 6 50 Maximum 2 80 80 CPCMAX 6 50 Korea Post Default All Korea Post Settings KPCDFT 6 51 Off KPCENA0 6 51 On KPCENA1 6 51 Korea Post Msg Length Minimum 2 80 4 KPCMIN 6 51 Maximum 2 80 48 KPCMAX 6 51 Korea Post Check Digit Transmit Check Digit KPCCHK1 6 51...

Page 150: ...9 26 ...

Page 151: ...e 838 x 640 pixels Skew Angle 65 Pitch Angle 45 Symbol Contrast Grade 1 0 20 or greater Voltage Requirements 4 5 5 VDC at input connector Current Draw 5VDC Scanning Standby 450mA 2 3W 90mA 45W Power Supply Noise Rejection Maximum 100mV peak to peak 10 to 100 kHz Temperature Ranges Operating 32 F to 122 F 0 C to 50 C Storage 40 F to 158 F 40 C to 70 C Humidity 0 to 95 non condensing Mechanical Drop...

Page 152: ... 20 3 104 1 13 mil UPC in 5 10 7 7 2 mm 12 7 254 17 8 182 9 20 mil Code 39 in 1 12 1 12 mm 25 4 304 8 25 4 304 8 6 7 mil PDF417 in 5 4 5 5 4 5 mm 12 7 114 3 12 7 114 3 10 mil Data Matrix in 5 5 5 5 5 5 mm 12 7 139 7 12 7 139 7 20 mil QR Code in 8 9 5 8 9 5 mm 20 3 241 3 20 3 241 3 Resolution 1D Code 39 3 mil 076mm 5 mil 127mm Resolution 2D Data Matrix 5 mil 127mm 5 mil 127mm ...

Page 153: ...y ground 4 5 6 7 5V power 8 9 Data 10 Data Note Pin assignments are not compatible with Honeywell legacy products Use of a cable with improper pin assignments may lead to damage to the unit Use of any cables not provided by the manufacturer may result in damage not covered by your warranty ...

Page 154: ...10 4 ...

Page 155: ... t operating well clean the window with one of the cleaning solutions listed for Health Care Housing below Health Care Housing Some configurations of Xenon scanners are available with an external plastic housing that is designed to resist the effects of harsh chemicals in a health care environment The plastic is crystalline in nature which helps prevent chemicals from seeping through the housing D...

Page 156: ...nnectors Inspect the interface cable and connector for wear or other signs of dam age A badly worn cable or damaged connector may interfere with scanner operation Contact your distributor for information about cable replace ment Cable replacement instructions are on page 11 2 Replacing Cables in Corded Scanners The standard interface cable is attached to the scanner with an 10 pin modular connecto...

Page 157: ...scanner is not functioning properly review the following Troubleshoot ing Guide to try to isolate the problem Is the power on Is the aiming beam on If the aiming beam isn t illuminated check that The cable is connected properly The host system power is on if external power isn t used The trigger works Is the scanner having trouble reading your symbols If the scanner isn t reading symbols well chec...

Page 158: ...may not be programmed to output your bar code data properly For example you scan 12345 and the host displays A12345B Reprogram the scanner with the proper symbology selections See Chapter 6 The scanner won t read your bar code at all 1 Scan the sample bar codes in the back of this manual If the scanner reads the sample bar codes check that your bar code is readable Verify that your bar code symbol...

Page 159: ...x 55 11 5185 8225 E mail brsuporte honeywell com Mexico Telephone 01 800 HONEYWELL 01 800 466 3993 E mail soporte hsm honeywell com Europe Middle East and Africa Telephone 31 0 40 7999 393 Fax 31 0 40 2425 672 E mail hsmeurosupport honeywell com Hong Kong Telephone 852 29536436 Fax 852 2511 3557 E mail aptechsupport honeywell com Singapore Telephone 65 6842 7155 Fax 65 6842 7166 E mail aptechsuppo...

Page 160: ... honeywell com Latin America Telephone 803 835 8000 Telephone 800 782 4263 Fax 239 263 9689 E mail laservice honeywell com Brazil Telephone 55 11 5185 8222 Fax 55 11 5185 8225 E mail brservice honeywell com Mexico Telephone 01 800 HONEYWELL 01 800 466 3993 Fax 52 55 5531 3672 E mail mxservice honeywell com Europe Middle East and Africa Telephone 31 0 40 2901 633 Fax 31 0 40 2901 631 E mail euroser...

Page 161: ... at purchaser s expense during the Warranty Period to HII factory or authorized service center for inspection No product will be accepted by HII without a Return Materials Authorization which may be obtained by contacting HII In the event that the product is returned to HII or its authorized service center within the Warranty Period and HII determines to its satisfaction that the product is defect...

Page 162: ...t if any provision is held invalid and unenforceable such determina tion shall not affect the validity of enforceability of the other provisions hereof Use of any peripherals not provided by the manufacturer may result in damage not covered by this warranty This includes but is not limited to cables power supplies cradles and docking stations HII extends these warranties only to the first end user...

Page 163: ...Code Han Xin Code X0 H 0x48 Codabar Fm 0 1 a 0x61 Codablock A O6 0 1 4 5 6 V 0x56 Codablock F Om 0 1 4 5 6 q 0x71 Code 11 H3 h 0x68 Code 128 Cm 0 1 2 4 j 0x6A GS1 128 C1 I 0x49 Code 32 Pharmaceutical PARAF X0 0x3C Code 39 supports Full ASCII mode Am 0 1 3 4 5 7 b 0x62 Code 49 Tm 0 1 2 4 l 0x6C Code 93 and 93i Gm 0 9 A Z a m i 0x69 Data Matrix dm 0 6 w 0x77 EAN 13 including Bookland EAN E0 d 0x64 E...

Page 164: ...IX Netherlands Post X0 K 0x4B Korea Post X0 0x3F Matrix 2 of 5 X0 m 0x6D MaxiCode Um 0 3 x 0x7 8 MicroPDF417 Lm 3 5 R 0x52 MSI Mm 0 g 0x67 NEC 2 of 5 X0 Y 0x59 OCR MICR E 13 B o3 O 0x4F OCR SEMI Font o3 O 0x4F OCR A o1 O 0x4F OCR B o2 O 0x4F PDF417 Lm 0 2 r 0x72 Planet Code X0 L 0x4C Postal 4i X0 N 0x4E Postnet X0 P 0x50 QR Code and Micro QR Code Qm 0 6 s 0x73 Straight 2 of 5 IATA Rm 0 1 3 f 0x66 ...

Page 165: ...rsal All Symbologies 99 entry Refer to Data Editing beginning on page 4 1 and Data Formatting beginning on page 5 1 for information about using Code ID and AIM ID TCIF Linked Code 39 TLC39 L2 T 0x54 Telepen Bm t 0x54 UPC A E0 c 0x63 UPC A with Add On E3 c 0x63 UPC A with Extended Coupon Code E3 c 0x63 UPC E E0 E 0x45 UPC E with Add On E3 E 0x45 UPC E1 X0 E 0x45 Symbology AIM ID Possible AIM ID Mod...

Page 166: ...MENT NAK 6 6 ACKNOWLEDGE ACK 22 16 SYNCHRONIZE SYN 7 7 BEEP BEL 23 17 END OF TRANSMISSION BLOCK ETB 8 8 BACKSPACE BS 24 18 CANCEL CAN 9 9 HORIZONTAL TAB HT 25 19 END OF MEDIUM EM 10 A LINE FEED LF 26 1A SUBSTITUTE SUB 11 B VERTICAL TAB VT 27 1B ESCAPE ESC 12 C FF FORM FEED 28 1C FILE SEPARATOR FS RIGHT ARROW 13 D CR CARRIAGE RETURN 29 1D GROUP SEPARATOR GS LEFT ARROW 14 E SO SHIFT OUT 30 1E RECORD...

Page 167: ... 120 78 x 57 39 9 89 59 Y 121 79 y 58 3A 90 5A Z 122 7A z 59 3B 91 5B 123 7B 60 3C 92 5C 124 7C 61 3D 93 5D 125 7D 62 3E 94 5E 126 7E 63 3F 95 5F _ 127 7F DEL Extended ASCII Characters DEC HEX Character DEC HEX Character DEC HEX Character 128 80 171 AB 214 D6 Ö 129 81 172 AC 215 D7 130 82 173 AD 216 D8 Ø 131 83 ƒ 174 AE 217 D9 Ù 132 84 175 AF 218 DA Ú 133 85 176 B0 219 DB Û 134 86 177 B1 220 DC Ü ...

Page 168: ...é 148 94 191 BF 234 EA ê 149 95 192 C0 À 235 EB ë 150 96 193 C1 Á 236 EC ì 151 97 194 C2  237 ED í 152 98 195 C3 à 238 EE î 153 99 196 C4 Ä 239 EF ï 154 9A š 197 C5 Å 240 F0 ð 155 9B 198 C6 Æ 241 F1 ñ 156 9C œ 199 C7 Ç 242 F2 ò 157 9D 200 C8 È 243 F3 ó 158 9E ž 201 C9 É 244 F4 ô 159 9F Ÿ 202 CA Ê 245 F5 õ 160 A0 203 CB Ë 246 F6 ö 161 A1 204 CC Ì 247 F7 162 A2 205 CD Í 248 F8 ø 163 A3 206 CE Î 249...

Page 169: ...um Replacement Characters 81 ISO 2022 25 Fra French Belgium Replacement Characters 84 ISO 2022 11 Ger German Replacement Characters 85 ISO 2022 11 Ita Italian Replacement Characters 86 ISO 2022 11 Swi Swiss Replacement Characters 87 ISO 2022 11 UK British Replacement Characters 88 ISO 2022 11 Dan Danish Replacement Characters 89 ISO 2022 11 Nor Norwegian Replacement Characters 90 ISO 2022 11 Spa S...

Page 170: ...54 59 3A 3B 3C 3E 3F 38 40 3D 5A 5F 64 5B 60 65 5C 61 66 5D 62 67 63 68 69 6A 6C 104 Key U S Style Keyboard 6E 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 4B 50 55 4C 51 56 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1E 2C 1F 20 21 22 23 24 25 26 27 28 29 2B 39 2E 2F 30 31 32 33 34 35 36 37 53 4F 54 59 3A 3B 3C 3E 3F 38 40 3D 5A 5F 64 5B 60 65 5C 61 66 5D 62 6...

Page 171: ......

Page 172: ...Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 Code 39 Codabar 1234567890 Code 128 9 780330 290951 BC321 A13579B Code 93 123456 9 Straight 2 of 5 Industrial 123456 ...

Page 173: ...Sample Symbols 6543210 GS1 DataBar 01 00123456789012 PDF417 Car Registration Data Matrix QR Code Test Symbol Numbers Matrix 2 of 5 Aztec Micro PDF417 Package Label Test Message ...

Page 174: ...Programming Chart 1 0 2 3 6 7 5 4 8 9 ...

Page 175: ...Programming Chart Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save again A C B F E D Save Discard Reset ...

Page 176: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 Xen1500 UG Rev A 10 11 ...

Reviews: