6 - 6
Code 39
< Default All Code 39 Settings >
Code 39 On/Off
Code 39 Start/Stop Characters
Start/Stop characters identify the leading and trailing ends of the bar code.
You may either transmit, or not transmit Start/Stop characters.
Default =
Don’t Transmit.
Code 39 Check Character
No Check Character
indicates that the scanner reads and transmits bar
code data with or without a check character.
When Check Character is set to
Validate, but Don’t Transmit
, the unit
only reads Code 39 bar codes printed with a check character, but will not
transmit the check character with the scanned data.
* On
Off
Transmit
* Don’t Transmit