background image

XM500 TCP/IP MODEM

74-3468—3    B.B.  Rev. 4-03 

www.honeywell.com

Printed in U.S.A. on recycled 
paper containing at least 10% 
post-consumer paper fibers.

Automation and Control Solutions

Honeywell International

Honeywell Europe S.A.

Honeywell Latin American 

  

Honeywell International Inc.

Honeywell Limited-Honeywell Limitée

Control Products

3 Avenue du Bourget

  

Region

1985 Douglas Drive North

35 Dynamic Drive

Honeywell Building

1140 Brussels

480 Sawgrass Corporate Parkway

Golden Valley, MN  55422

Scarborough, Ontario

17 Changi Business Park Central 1

Belgium

Suite 200

M1V 4Z9

Singapore  486073

Sunrise FL  33325

Verbose Result Codes

1.

Unsupported modem commands return <ok>.

2.

A TCP/IP connection refused equates to <busy>

3.

No connection equates to <no carrier>.

User Commands

Table 2 shows the user commands that are commonly used 

and necessary in order to initialize the XM500 for 

communication with EXCEL 5000 system devices.

Table 2. User Commands.

a

Autobauding is only supported for 9.600, 19.200 and 

38.400 bps.

NOTE: The terminal mode is fixed. That is, eight bits per 

character, one stop bit, no parity bits, no S/W flow 

control.

Cable Specifications

RS-232 CABLE (RJ45 TO DB9/DB25)

IMPORTANT

The RS-232 cable is a special calibration cable. 

Standard RJ45 to RS-232 connectors will not work.

Table 3. PIN Assignment RS-232 Cable.

a

Note that the DTR signal is looped back in order to supply 

DSR to the terminal (XBS or EXCEL 5000 CPU).

ETHERNET CABLE

Use a standard 10BASE-T twisted pair Ethernet cable with 

RJ45 plugs.

L

ON

S

PEC

™ and L

ON

S

TATION

™ are trademarks of Echelon

®

 Corporation.

Command

Description

autobaud

a

display or set the autobauding state: <on> or <off>.

Default is <off>.

ifconfig

display or set network interface information.

lockmem

display or set the system parameters lock state <on> or <off>.

ping

send ICMP ECHO_REQUEST datagrams.

route

display or modify the routing table.

stty

display or set the serial baud rate.

PIN at RJ45

Description

PIN at DB9

PIN at DB25

1

DCD 

1

8

2

 RTS

7

4

3

GND

5

7

4

RxD 

2

3

5

 TxD

3

2

6

no connect

7

CTS 

6

a

,8

5,6

a

8

 DTR

4

20

By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use 

or  modification  to,  the  literature.  You  will  defend  and  indemnify  Honeywell,  its  affiliates  and  subsidiaries,  from  and 

against any liability, cost, or damages, including attorneys’ fees, arising out of, or resulting from, any modification to the 

literature by you.

Summary of Contents for XM500

Page 1: ...ually via Windows Terminal Program The LAN WAN network server requires no software download for the XM500 FEATURES Communication between XBS or LONSTATION centrals and EXCEL 5000 controllers via standard Ethernet TCP IP LAN WAN TCP IP provides more reliable and faster communications than analog modem Compatible with all HVAC systems connecting through an SLTA 10 Compatible to EXCEL 5000 controller...

Page 2: ...emperature 14 to 158 F 10 to 70 C Relative humidity 10 to 95 non condensing Processor and Memory Main processor 68HC000 Ethernet Coprocessor SMC91C96 Memory RAM 64K byte with 2K byte NVRAM EPROM 256K byte Software IP Connect software is provided to configure the XM500 modem The various controllers and workstations are configured using Honeywell specific software for serial communication with EXCEL...

Page 3: ...l serve as the telephone number for the workstation or EXCEL controller that is connected to it EXAMPLE 160 221 71 130 NOTES 1 If communication is only done internally in the LAN unofficial IP addresses will be sufficient 2 If only dynamic IP addresses are available Use a DHCP server and have it allocate the identical IP address every time it does a dynamic IP address allocation 3 For an intermedi...

Page 4: ...blank configuration screen 13 When the modem is ready the status screen should read Please select device XM500 is connecting to 14 Choose the device which the modem is going to be connecting to or the workstation from which the modem is connecting NOTE If you are connecting from XBS make sure you choose the same baud rate as the controller to which you connect 15 Once you have chosen a device the ...

Page 5: ...em is not connected to a network LONSTATION and LONSPEC Configuration 1 Begin from the desktop 2 Double click My Computer 3 Double click Control Panel 4 Double click Modems 5 Click Add 6 Click the box Don t detect my modem I will select it from a list 7 Click Next 8 Under Manufacturers column click Standard Modem Types 9 Under Models column click Standard 28800 bps Modem 10 Click Next IMPORTANT De...

Page 6: ... an IP address 160 221 71 130 with appropriate network mask 255 255 252 0 note the blank space between IP address and network mask d route add net default 160 221 68 1 1 Example of a gateway definition Please check with the local network administrator if a gateway definition is necessary The parameters are the default gateway address 160 221 68 1 and the number of hops to the gateway 1 They must b...

Page 7: ...been initialized it will always and consistently show the same pre defined serial behavior Table 1 Hayes Command Set EXAMPLE Command ping 160 221 71 131 Answer 160 221 71 131 is alive This answer means that the TCP IP communication to the target XM500 is working If the target XM500 cannot be reached the answer will be no answer from 160 221 71 131 Command Description Hang up close connection A A0 ...

Page 8: ...ow control Cable Specifications RS 232 CABLE RJ45 TO DB9 DB25 IMPORTANT The RS 232 cable is a special calibration cable Standard RJ45 to RS 232 connectors will not work Table 3 PIN Assignment RS 232 Cable a Note that the DTR signal is looped back in order to supply DSR to the terminal XBS or EXCEL 5000 CPU ETHERNET CABLE Use a standard 10BASE T twisted pair Ethernet cable with RJ45 plugs LONSPEC a...