SINGLE SIDED MODELS
SUITABLE GAS BURNER OPTION
CANTILEVER
700 Cantilever
700 Mk2 Pebble
700 Mk2 Coal
700 Ironbark Log Mk4
1100 Cantilever 1000 Mk2 Pebble
1000 Mk2 Coal
850 Ironbark Log Mk4
1500 Low Line 1400 Mk2 Pebble
1400 Mk2 Coal
DOUBLE SIDED MODELS
Power Flue approved for the
following models:
Installation Instructions Kemlan Power Flue Horizon Gas Fireplaces
Location Requirements
Power flue systems utilizes a fan assisted draft to
ensure products of combustion are exited through a
flue terminal either horizontally or vertically
terminated.
The following A.G.A location requirements for flues
are to be observed when installing a powered flue
system.
SEE NEXT PAGE FOR LOCATION EQUIREMENTS
Ventilation Requirements:
Rooms with gas open fireplaces require as per
clause 6.10.9.5 in AS/NZS5601.1:2013, one or more
ventilation openings with a combined free ventilation
area of not less than the equivalent cross sectional
area of the flue cowl shall be provided for each
decorative flame effect fire and calculations based
on clause 6.4.4
Model Type 2: Power Flue
Decorative Gas Fireplace
DATA PLATE: Refer to information on page 16 of this
Instruction booklet in respect to gas pressure,
consumption and gas type, Natural, ULPG or LPG.
Data Plate is located under the gas burner and is
accessed by lifting front access panel or removing
base plate.
700 Low Line
700 Mk2 Pebble
700 Mk2 Coal
700 Ironbark Log Mk4
850 Low Line 800 Mk2 Pebble
800 Mk2 Coal
850 Ironbark Mk4
1100 Low Line
1000 Mk2 Pebble
1000 Mk2 Coal
850 Ironbark Log Mk4
1500 Low Line 1400 Mk2 Pebble
1400 Mk2 Coal
2000 Low Line 1800 Mk2 Pebble
1800 Mk2 Coal
700 Low Line
700 Mk2 Pebble
700 Mk2 Coal
700 Ironbark Log Mk4
850 Low Line 800 Mk2 Pebble
800 Mk2 Coal
850 Ironbark Mk4
1100 Low Line
1000 Mk2 Pebble
1000 Mk2 Coal
850 Ironbark Log Mk4
1500 Low Line 1400 Mk2 Pebble
1400 Mk2 Coal
2000 Low Line 1800 Mk2 Pebble
1800 Mk2 Coal
28/02/2019
Ver. 25
NOTE:
The chimney in which the appliance is installed
is not to be considered as a ventilation opening.
PLEASE NOTE:
All power flue external joints (inc. flue joints,
attenuator, Fan, etc.) must be sealed with
approved heat rated (149°C minimum
continuous exposure rating) foil tape
after joining sections! Internal flues do not
need to be sealed with foil tape.
2