137
Replacing the Fuses /
Ma
intena
nce
6
6-11
Replacing the Fuses
1
Identify which fuse has blown by
checking the machine.
- Any fuse may be blown if the following error
codes are displayed on the Error screen.
- If an error code is not displayed, some
symptoms can indicate the problem. Iden-
tify which fuse has blown by checking the
symptom.
- Fuse replacement must be supervised by a maintenance administrator.
- Turn off the power switch and unplug the power cord before replacing a fuse.
WARNING
1102
11119
61101A1
Error Code
Error Code
Fuses
1102
Fuse F02 on the SPF Power Board
QPW-757
4102
8300
Fuse F1 on the Fore-edge Trim Knife
Section Control Board QPM-237
Symptom
Fuses
- The delivery
conveyor does
not move.
Fuse F60 on the SPF Power
Board QPW-757 (if the delivery
conveyor is installed on the SPF
main unit).
Fuse F60 on the Fore-edge Trim
Knife Section Power Board
QPW-757 (if the delivery con-
veyor is installed on the fore-
edge trim knife section.)
- The trim is not
collected. (The
blower does not
work.)
Fuse F02 on the Fore-edge Trim
Knife Section Power Board
QPW-757
11119
61101E1
11119
61101B1
F1
F1
(3.15A)
(3.15A)
F1
(3.15A)
11119
61101C1
11119
61101F1
F02
(1.0A)
F60
(0.5A)
F02
(1.0A)
F60
(0.5A)
11119
61101G1
Fore-edge Trim Knife Section
Control Board QPM-237
Spare Fuses
Power Board QPW-757
Power Board
QPW-757
Spare Fuses
Rear Side of Machine
Summary of Contents for Bookletmaker FC-200A
Page 84: ...This page is intentionally left blank...
Page 94: ...This page is intentionally left blank...
Page 146: ...This page is intentionally left blank...
Page 202: ...This page is intentionally left blank...
Page 217: ...This page is intentionally left blank...
Page 218: ...Manufacturer Phone 81 75 934 6700 Fax 81 75 934 6708 www horizon co jp...