100
CRF-362
5-1
Double Feed Stop Pad Assembly Replacement
The double feed stop pad assembly in the feed section is consumables. Replace the assembly when a double
feeding occurs frequently even if you follow the instructions in page 89 .
1
Turn off the Power switch.
2
Raise the double feed stop pad
assembly adjusting lever.
→
The double feed stop pad assembly lowers
and you can replace the assembly easily.
3
Loosen the two locking screws.
You do not need to remove them completely.
4
Remove the double feed stop
pad assembly by sliding it up-
ward.
5
Install the new double feed stop
pad assembly and attach it using
the two mounting screws.
Tighten the locking screws while pressing
the assembly down to level the assembly.
6
See page 67 and adjust the height of the double feed stop pad
assembly.
13130
50101A1
Locking Screws
13130
50101B1
This corner
may be
worn.
13130
50101C1
13130
50101D1
Good
Bad
13130
50101A2
Double Feed Stop
Pad Assembly
Double Feed Stop Pad
Assembly Adjusting Lever
Summary of Contents for CRF-362
Page 10: ...This page is intentionally left blank ...
Page 49: ...This chapter explains the procedure for us ing convenient functions 2 2 Advanced Operation ...
Page 64: ...This page is intentionally left blank ...
Page 65: ...3 3 Adjustments This chapter explains how to make some adjustments that may be necessary ...
Page 80: ...This page is intentionally left blank ...
Page 98: ...This page is intentionally left blank ...
Page 99: ...5 This chapter explains how to replace the consumables and clean the machine 5 Maintenance ...
Page 114: ...This page is intentionally left blank ...
Page 115: ...6 7 This chapter lists the specifications for this machine 7 Appendix ...
Page 121: ...This page is intentionally left blank ...
Page 122: ...Manufacturer Phone 81 75 934 6700 Fax 81 75 934 6708 www horizon co jp ...