319
SmartStacker User's Manual
If an Error Code Is Displayed on SmartStacker
Code
Description and Causes
Solutions
5952
Inverter Alarm
Input Phase Failure
(Inverter Display: E.ILF)
A phase failure has occurred in one of the three
input phases (R, S and T) to the inverter, or there
was a big difference in voltage between the input
phases. This has stopped the output from the
inverter.
If this error occurs frequently, call your local
dealer.
5960
Inverter Alarm
Stall Prevention
(Inverter Display: E.OLT)
The operating frequency has been dropped to “0”
by the stall preventer function.
5970
Inverter Alarm
Brake Circuit Problem
(Inverter Display: E.BE)
The brake transistor has failed due to excessive
regenerative energy from the motor. The output
from the inverter has been stopped.
Turn off the power. Wait about 30 minutes and
turn on the power again. If this error occurs
frequently, call your local dealer.
5980
Inverter Alarm
Current Leakage Protection
(Inverter Display: E.GF)
A ground fault has occurred in the power supply
circuit of the motor, and the inverter stopped the
output.
If this error occurs frequently, call your local
dealer.
5981
Inverter Alarm
Output Phase Failure Protection
(Inverter Display: E.LF)
A phase failure has occurred in one of the three
output phases (U, V and W) from the inverter. The
output from the inverter has been stopped.
5990
Inverter Alarm
Parameter Problem
(Inverter Display: E.PE)
A parameter saved for the inverter is bad.
5999
No Error Code for Inverter
(Inverter Display: N/A)
An error which does not correspond to any of the
errors 5900 through 5998 has occurred on the
A540.
Summary of Contents for SmartStacker
Page 106: ...This page is intentionally left blank ...
Page 110: ...110 SmartStacker User s Manual Daily Safety Check Lift the cover pressing the hooks Hooks ...
Page 146: ...This page is intentionally left blank ...
Page 170: ...This page is intentionally left blank ...
Page 206: ...This page is intentionally left blank ...
Page 207: ...6 This chapter explains some possible problems and suggests some solutions 6 Troubleshooting ...
Page 367: ...367 SmartStacker User s Manual If a Jam Occurs B2 Stacker Option 10606650901C1 Feeder Option ...
Page 368: ...This page is intentionally left blank ...
Page 376: ...376 SmartStacker User s Manual SmartStacker Merge Conveyor Merge Stacker B2 Stacker Optional ...
Page 379: ...379 SmartStacker User s Manual SmartStacker B2 Stacker Optional Vacuum Belt ...
Page 381: ...381 SmartStacker User s Manual SmartStacker Merge Conveyor ...
Page 390: ...This page is intentionally left blank ...
Page 391: ...6 8 This chapter lists the specifications for this machine 8 Appendix ...
Page 411: ...This page is intentionally left blank ...
Page 412: ...Manufacturer Phone 81 75 934 6700 Fax 81 75 934 6708 www horizon co jp ...