Distributed Exclusively By: 

                                    

 

  Air Cleaning Equipment, Inc.

    

  Broadway, NC 27332

             

   

www.horizondehumidifiers.com

  

     

 
 

 

Summary of Contents for VERT series

Page 1: ... or ri iz zo on n V VE ER RT T I In ns st ta al ll la at ti io on n a an nd d O Op pe er ra at ti io on ns s M Ma an nu ua al l R Re ea ad d a an nd d S Sa av ve e T Th he es se e I In ns st tr ru uc ct ti io on ns s Distributed Exclusively By Air Cleaning Equipment Inc Broadway NC 27332 www horizondehumidifiers com ...

Page 2: ...__________________________________________ VERT Series Owner s Manual 2 Horizon VERT Humidistat Fan Switch O Auto I Constant On Drain Line Connection Push line into to secure Release by pushing in blue ring surrounding tube and pull tube out ...

Page 3: ...t unit the unit should be opened and allowed to dry thoroughly before reconnected to electric and restarting For proper operation neither the inlet nor discharge should be positioned against a wall The inlet requires a minimum of 12 clearance and the discharge needs a minimum of 24 clearance For proper diffusion of air throughout the room the dehumidifier should be positioned so that the discharge...

Page 4: ...3 Do not use extension cord 4 Do not use plug adapter Power Supply 115V 60 Hz AC Only 1 Phase Outlet Requirement 3 Prong GFI Circuit Protector 15 Amp Time Delay Fuse or Circuit Breaker Principle of Operation The VERT Series Dehumidifier utilizes its integral humidistat or optional remote mount humidistat to monitor the conditioned space When the relative humidity goes above the selected set point ...

Page 5: ...ntation wait a minimum of 2 hours before turning the unit on Drain Line o Standard Unit Unit has a quick connect adapter on its side for connection of the included 8 mm drain line 25 of drain line is included Route drain line to drain or outside of the area Drain line MUST have a downward slope to drain or condensate pump Plug unit into 15 amp grounded outlet Determine whether you want constant fa...

Page 6: ...til cleaning interval for your application can be properly established In most instances the filter can be vacuumed once after approximately 3 months and then replaced after approximately 6 months Maintenance Proper maintenance of air filters is required to prevent extensive cleaning of heat exchanger and coils 1 Unplug Unit 2 Filter may be cleaned by a Vacuuming b Or Replace with similar 20 x 14 ...

Page 7: ... 115 VOLT 60 HERTZ SINGLE PHASE FINISH POWDER COATED EPOXY OPERATING RANGE 45 F TO 90 F REFRIGERANT See Data Label CONDENSATE DRAIN SIZE 8 mm Quick Connect AMPS FULL LOAD AT 80F 60 7 5 FLA POWER CORD 20 GROUNDED PLUG FILTER SIZE 20x14 Parts List DH 100 101 Compressor DH 100 101 Humidistat DH 100 102 Blower w Capacitor DH 100 103 Thermostat DH 100 104 Compressor Capacitor DH 106 Power Cord DH 100 1...

Page 8: ...s not include any cost of labor including but not limited to labor to remove and or reinstall any defective part refrigerant or piping Customer may elect to have unit fixed locally in which case required replacement parts will be sent to customer at customer s expense ACE shall not be responsible for loss of use of any product loss of time inconvenience or damage to other equipment or any other in...