background image

3

TROUBLESHOOTING

USEFUL INFORMATION / MAINTENANCE

1.

SWITCHING FROM AC TO DC SOLAR OR WIND POWER OPTIONS

HYDROFILL PRO can be powered by using the standard (included) AC to DC power cable (b), or can be 

connected to renewable power sources such as solar PV or small wind turbines. Both sources should 

include a battery buffer to regulate power supplied to the HYDROFILL PRO.

Recommended Solar PV system set-up:

-Min. 25W-40W Solar PV panels with battery charge controller (not included) 

-11V - 14.4V / 10-15Ah battery (not included)

-DC cable (plug compatible to HYDROFILL PRO DC socket) (not included) 

Recommended wind turbine system set-up:

-Min. 40W wind turbine with battery charge controller (not included) 

-11V - 14.4V / 10-15Ah battery (not included) 

-DC cable (plug compatible to HYDROFILL PRO DC socket) (not included)

 

 

Only use 

de-ionized or distilled water.

Wait for half an hour to start the HYDROFILL PRO after adding water to the water tank if it is used for the 

first time or it has been stored for more than 2 months.

4-6.5 hours of operation will normally be required to fully charge an empty HYDROSTIK or HYDROSTIK PRO

.

The HYDROFILL PRO can still run and generate hydrogen even if the LED light alternates between red for 1 

second and off for 3 seconds, but  HYDROSTIK or HYDROSTIK PRO 

charging time will be slower.

If the LED status indicator light alternates red for 1 second and off for 1 second, check the water level of the 

water tank and waste water tank. Either add water to the water tank or remove water from the waste water 

tank as required. Follow set up instructions carefully.

solar charge 

controller

11-14.4V battery

25W-40W solar panels

40W wind turbine

AC cord

11-14.4V battery

wind-charge 

controller

DC cable

DC cable

DC cable

The

 LED status indicator light does not flash green after the power supply cord is connected.

SOLUTION

: Check the connection between the AC-DC adapter and the power supply.

HYDROFILL PRO

3. Fully insert the  HYDROSTIK or HYDROSTIK PRO cartridge into the HYDROFILL PRO unit by turning it 

clockwise into the cartridge port until firmly secured. During the insertion process, the green indicator 

light may turn red to indicate a connection (Fig D), but continue turning to make sure the  HYDROSTIK or 

HYDROSTIK PRO is firmly secured (Fig E).  Secure the  HYDROSTIK or HYDROSTIK PRO tightly to the unit, 

but be careful not to apply excessive force.

OPERATION INSTRUCTIONS

2

STATUS INDICATOR LIGHTS

The ridge

 is the 

water le

v

el

4. While the indicator light is RED, your  HYDROSTIK or HYDROSTIK PRO cartridge is being filled with 

hydrogen. The  HYDROSTIK or HYDROSTIK PRO cartridge is fully charged  when the indicator lights GREEN. 

When completed, disconnect the  HYDROSTIK or HYDROSTIK PRO cartridge from the HYDROFILL PRO (turn 

anti-clockwise to disconnect). 

Note: 1. It will be normal to hear short bursts or puffs during the refilling procedure, due to 

water being purged from the system from time to time.

2. It will be normal to hear the sound of air being released when the  HYDROSTIK or HYDROSTIK PRO is disconnected from the 

HYDROFILL PRO. 

5. Disconnect the HYDROFILL PRO from the AC and empty the water tank if you will not use the HYDROFILL 

PRO within one hour. If more cartridges need to be charged, repeat step 3. 

1. Open the water tank cover located at the top of the unit (Fig. A). Carefully add de-ionized or distilled 

water

** EXACTLY up to the ridge level inside the water tank as shown below in Fig. B. Close the cover.

Wait for half an hour to start the system after adding water for the first time use or the product has 

been stored for more than 2 months.

WARNING: 

Only use de-ionized 

or distilled water.

Ridge

status indicator light 

will switch from 

green to red

Green

System Status

on

 HYDROSTIK or HYDROSTIK PRO cartridge is full

on

 HYDROSTIK or HYDROSTIK PRO cartridge is being filled 

on 1 second, off 1 seconds

Add water or empty waste water tank

on 1 second, off 1 second

Waiting to fill  HYDROSTIK or HYDROSTIK PRO cartridge 

Red

connect  HYDROSTIK 

or HYDROSTIK PRO 

until firmly secured

2. Connect the AC-DC adapter to the unit  (Fig. C).

Once plugged in to an AC point, the unit’s status indicator light should start to flash green.

AC-DC adapter (b)

Fig. A

Fig. B

Fig. C

Fig. D

Fig. E

Reviews: