To start the generator:
•
Make sure all the 110v systems have been switched off prior to starting
the generator.
•
Press the glow switch down for 5 seconds before engaging the start
button.
•
Pinch the two switches together and hold until the psi gauge reaches 58.
Release the switches. The generator is now running.
•
Allow the generator to warm up for 5 minutes and then gradually load up
the system, adding one load every 2 minutes.
Stopping the generator
•
Turn off all 110v systems.
•
Allow the generator to cool down for 5 mins without load.
•
Press down on the bottom switch and release immediately. The generator
will stop.
Glow switch. Press down for 5
seconds before engaging the start
switch.
Start/stop switch. To start the
generator pinch the start and glow
switches together. Hold until the psi
reaches over 58. Release.
To stop the generator press the
bottom switch down once and
release immediately.
The generator start panel
is located underneath the
12 volt and above the AC
controls.