background image

4/16/2021 | MAN1201-04-EN

Indianapolis, USA  |  Cork, Ireland  |  Calgary, Canada  |  Bangalore, India  |  Oakleigh, Australia  |  Tianjin, China  |  Esteio, Brazil

Please visit our website for a complete listing and to learn more about certified Horner Automation products.
This document is the property of Horner Automation Group, and is subject to change. 

RCC SERIES QUICK REFERENCE GUIDE

page 1 of 4

1.  General Specifications

RCC972 Required Power (Steady State)

130mA @ 24VDC

RCC1410 Required Power (Steady State)

120mA @ 24VDC

RCC2414 Required Power (Steady State)

120mA @ 24VDC

RCC8842 Required Power (Steady State)

120mA @ 24VDC

Inrush Current

RCC972

:    30A for 1ms @ 24VDC                    

RCC1410

:   25A for 1ms @ 24VDC switched

RCC2414

:  25A for 1ms @ 24VDC switched

RCC8842

: 25A for 1ms @ 24VDC switched

Primary Power Range

RCC972

:    10-32VDC

RCC1410

:   10-32VDC

RCC2414

:  10-28VDC

RCC8842

: 10-32VDC

Relative Humidity

5 to 95%  Non-condensing

Operating Temp.

-10°C to +60°C

Storage Temp.

-20°C to +70°C

Weight

10 oz (283.5g) 

Certifications  

(CE)

USA:    https://hornerautomation.com/certifications/ 
Europe:  https://www.hornerautomation.eu/support/certifications-2/

RCC

Real 

Time Clock

DC In 

12/24VAC

DC Out 

24VDC

Analog In 

0-20mA

Analog Out 

0-20mA

RCC972

No

8

4

8

4

RCC8842

Yes

8

8

4

2

RCC2414

Yes

2

4

1

4

RCC1410

Yes

14

10

6

HE-RCC1410

1

2

3
4

5

7

8

9

10

10

1. 

CAN Port Connector

2.  I/O Connector (A)
3.  Run/Idle Switch
4.  Load Switch
5.  Ethernet Port(s)
6.  Serial Port(s)
7.  Status LEDS
8.  I/O Connector (B)
9.  Power Connector
10.  microSD Memory Card
11.  Mini-USB Programming
12.  USB Flash Memory

2. Port Connectors 

1

8

7

5

4

3

2

9

HE-RCC972

6

HE-RCC2414

1

2

6

3 4

5

7

9

10

12

11

HE-RCC8842

1

2

3
4

5

6

7

8

9

10

NOTE:

 See Precaution #12 about USB and grounding. 

Summary of Contents for HE-RCC1410

Page 1: ...4VDC switched Primary Power Range RCC972 10 32VDC RCC1410 10 32VDC RCC2414 10 28VDC RCC8842 10 32VDC Relative Humidity 5 to 95 Non condensing OperatingTemp 10 C to 60 C Storage Temp 20 C to 70 C Weight 10 oz 283 5g Certifications CE USA https hornerautomation com certifications Europe https www hornerautomation eu support certifications 2 RCC Real Time Clock DC In 12 24VAC DC Out 24VDC Analog In 0...

Page 2: ...4 Digital In4 I3 Digital In3 I2 Digital In2 I1 Digital In1 AI1 AI2 AI3 AI4 AI5 AI6 AI7 AI8 C AQ1 AQ2 AQ3 AQ4 C CH CL LOOP PWR CAN High CAN Low 20mA 0 20mA TRANSMITTER Analog I O 1 Analog In1 2 Analog In2 3 Analog In3 4 Analog In4 5 Analog In5 6 Analog In6 7 Analog In7 8 Analog In8 C OV 1 Analog Out1 2 Analog Out2 3 Analog Out3 4 Analog Out4 OV OV CH CAN High CL CAN Low Power Wiring To power up the...

Page 3: ... power up the RCC8842 supply 10 32VDC to the V and V connections on the Power CAN and Analog Connector 1 2 V Digital Output Wiring V 1 2 3 4 V2 10 24VDC HE RCC8842 8 Digital Inputs 8 Digital Outputs 4 Analog Inputs 2 Analog Outputs Digital Input Wiring V V on top connector on top connector Digital Output Wiring Analog Input Wiring CAN PWR AND ANALOG I O CONNECTOR 9 10 11 V SENSOR SENSOR 0 10V Loop...

Page 4: ... To reduce the risk of fire electrical shock or physical injury it is strongly recommended to fuse the voltage measurement inputs Be sure to locate fuses as close to the source as possible 3 Replace fuse with the same type and rating to provide protection against risk of fire and shock hazards 4 In the event of repeated failure do NOT replace the fuse again as repeated failure indicates a defectiv...

Reviews: