WCM802/900
20
JUN
2005
PAGE
33
TT (Streaming Limit) Command
<Networking> TT Command defines a limit on
the number of bytes that can be sent out before a
random delay is issued. TT Command is used to
simulate full-duplex behavior.
If a module is sending a continuous stream of RF
data, a delay is inserted which stops its
transmission and allows other modules time to
transmit (once it sends number of bytes specified
by TT Command). Inserted random delay lasts
between 1 & ‘RN + 1’ delay slots, where each
delay slot lasts 38 ms.
VR (Firmware Version) Command
<Diagnostics> Read the Firmware Version of the
WCM802 / WCM900 Module.
WR (Write) Command
<(Special)> WR Command writes configurable
parameters to the module’s non-volatile memory
(Parameter values remain in the module’s
memory until overwritten by future use of WR Command).
If changes are made without writing them to non-volatile memory, the module reverts back to
previously saved parameters the next time the module is powered-on.
AT Command: ATTT
Binary Command: 0x1A (26 decimal)
Parameter Range: 0 – 0xFFFF (0 = disabled)
Default Parameter Value: 0xFFFF (65535
decimal)
Number of bytes returned: 2
Related Commands: RN (Delay Slots)
Minimum Firmware Version Required: 4.22
AT Command: ATVR
Binary Command: 0x14 (20 decimal)
Parameter Range: 0 – 0xFFFF [Read-only]
Number of bytes returned: 2
AT Command: ATWR
Binary Command: 0x08