tion is turned Off.
Cut – Disables ignition controlled door locks.
D
Doooorr U
Un
nlloocckk P
Pu
ullssee sseettttiin
ngg ((G
GR
RE
EE
EN
N)) - Provided to match the
requirements of either a single or double pulse output to unlock
the doors. Default is single pulse.
Uncut – The control will output a single pulse to unlock
the doors.
Cut – The control will output 2 pulses to unlock the doors.
D
Doooorr U
Un
nlloocckk O
Ou
uttp
pu
utt P
Pu
ullssee D
Du
urraattiioon
n ((W
WH
HIIT
TE
E)) - Provided to
match the requirements of either a lock/unlock pulse duration
output of 800 msec or 3.5 seconds. Default is 800 msec.
Uncut – The control will output a pulse of 800msec.
Cut – The control will output a pulse of 3.5 sec.
F
FA
AD
D//R
RA
AP
P C
Caan
ncceellllaattiioon
n ((G
GR
RE
EE
EN
N//B
BL
LA
AC
CK
K) - This loop controls
when the Green/Black (H1/7) wire outputs a negative pulse
either before or after the remote start is active. Uncut the H1/7
wire will pulse negative prior to remote start, this is normally
used as a Factory Alarm Disarm (FAD) output. When this loop
is cut, the Green/Black (H1/7) wire outputs a negative pulse
after the remote start shuts down, this is normally used to disable
vehicles with Retained Accessory Power (RAP) (e.g. the radio
stays powered until the doors are opened).
Uncut – FAD