Diagnostics program
In the diagnostics program the input
and output signals can be tested.
Key for seed metering motor:
The seed metering motor runs until the
key is pressed again. The display shows
and successively counts the seed motor
pulses.
Key tram line left ON:
The wings for the left hand tram line must
close and the display changes the left tram
line indication to "ON".
Key tram line left OFF:
The wings for the left hand tram line must
open and the display changes the left tram
line indication to "OFF".
Key tram line right ON:
The wings for the right hand tram line must
close and the display changes the right tram
line indication to "ON".
Key tram line right OFF:
The wings for the right hand tram line must
open and the display changes the right tram
line indication to "OFF".
Continue to next diagnostics page:
Return to the machine data selection.
1.
2.
3.
4.
5.
6.
7.
Fan pulses:
When the fan is running the pulses are continu-
ously counted.
Radar pulses:
During travel the radar pulses are successively
counted.
Work position:
Here the work signal of the hydraulic pressure
switch can be checked. With the machine low-
ered "0" must be indicated, in lifted condition the
display changes to 1.
Calibration switch:
Normal indication "0", when turning off the dis-
play changes to 1.
Power consumption:
Shows the present current consumption.
Filling level hopper 1 (seed hopper)
Indicates the switching condition of the hop-
per sensors. With an empty hopper the display
changes from 0 to 1.
With several hoppers the system does not indi-
cate which sensor has switched.
Filling level hopper 2 (bridging)
Indicates the switching condition of the sensors
in the metering unit. The sensors monitor bridg-
ing in the seed hopper and warn in case of an
empty metering unit.
With an empty metering unit the display changes
from 0 to 1.
With several metering units the system does not
indicate which sensor has switched.
Use the arrow key (6) to switch to the
second diagnostics page.
6
7
2
3
4
5
1