49
WHAT HAPPEN IF...
THE PELLET DOES NOT IGNITE
In case of failed ignition the FAIL IGN alarm is displayed. Press P4 to bring the stove back to its standard mode.
THERE IS A POWER SUPPLY FAILURE
In case of a power supply failure, when the electricity comes back on, select FINAL CLEANING mode and wait for the fume
temperature to drop below Pr value.
29.
ALARMS
The system signals a possible operating default in different ways, on the basis of the alarm type.
Here is a list of possible alarms:
Cause of alarm
Display
Fume temperature probe
01 – FUME PROBE ALARM
Hot fume
02 - HOT TEMPERATURE ALARM
Failed ignition
03 - ALARM NO FIRE
Switching off during the work stage
04 - NO FIRE ALARM
Failed mains power source
05 - ALARM BLACK-OUT ALARM
Safety pressure switch
06 – LOW NEGATIVE PRESSURE ALARM
Safety thermostat
07 – TANK THERMOSTAT ALARM
Faulty fume exhaustion fan
08 – FAULTY FUME EXHAUSTION FAN ALARM
THE STOVE AUTOMATICALLY SHUTS DOWN IN CASE OF ALARM.
The alarm status is reached after the parameterized time within the operation card and can be reset by pressing the P4 key.
FUME PROBE ALARM
The alarm will go off if the fume probe is broken or disconnected. During the alarm, the stove shuts down automatically.
HOT TEMPERATURE ALARM
It occurs when the fume probe detects a temperature over 270°C. During the alarm, the stove shuts down automatically.
The cause of the shutdown can be: pellets exhausted inside the tank, auger motor blocked.
FAILED IGNITION ALARM
It occurs when the stove ignition fails. During the alarm, the stove shuts down automatically.
SWITCHING OFF DURING THE WORK STAGE ALARM
If, during the working stage, the flame burns down and the fume temperature drops below the minimum operating threshold the
alarm goes off. During the alarm, the stove shuts down automatically.
SAFETY PRESSURE SWITCH ALARM
If the pressure switch detects a pressure below the tripping threshold, it shuts the auger off. During the alarm, the stove shuts
down automatically.
GENERAL THERMOSTAT ALARM
If the general safety thermostat detects a temperature above the standard specification in the fuel tank, it blocks the auger power
supply. During the alarm, the stove shuts down automatically.
FAULTY FAN IN THE FLUE GASES EXHAUSTION SYSTEM
If the fan in the fume exhaustion system breaks down, the stove stops working.
Summary of Contents for DOMUS
Page 6: ...6 FIG 1 ...
Page 30: ...30 PELLET STOVE DOMUS INSTALLATION AND MAINTENANCE MANUAL MOD DOMUS EN ...
Page 45: ...45 ...
Page 55: ...55 ...
Page 56: ...56 POÊLE À GRANULÉS DOMUS GUIDE D INSTALLATION D UTILISATION ET D ENTRETIEN MOD DOMUS FR ...
Page 80: ...80 ...
Page 81: ...81 PELLETKACHEL DOMUS INSTALLATIE GEBRUIKS EN ONDERHOUDSHANDLEIDING MOD DOMUS NL ...
Page 87: ...87 FIG 1 ...
Page 88: ...88 13 TECHNISCHE GEGEVENS ...
Page 100: ...100 ...
Page 109: ...109 ...